1
3. Cooling a. Introduction 1) Definition reduce temperature of air entering greenhouse Why? –Reduce stress –Uniformity –Better growth
2
2) Types of systems a) refrigeration system b) evaporative cooling pad and fan high pressure mist - fog b. Evaporative/cooling
3
Evaporative cooling 1) Principal –Energy Required –H2O (liquid) + Warm air (energy) > H2O (gas) + cooler air –1000 BTU to change 1 lb liquid H2O to gas (water vapor)
5
2) Factors determining cooling –Temperature: outside air –Relative humidity: outside air –Temperature: inside air –air movement –shading –structure –Covering Evaporative Cooling
6
c. Pad and fan system –80% to 90% of difference between wet and dry bulb –Temp increases from inlet to outlet –higher moisture (outside) reduces temp decrease
7
80% to 90% of difference between wet and dry bulb Cooling efficiency
8
1) design of system pad and fan system –Equipment Separate house Ridge and furrow –Fan and pad size fans, same as for ventilation –pads, based on fan size and material
9
2)Important points in operation –Eliminate leaks through pads around pads other areas –Uniform wetting holes clogged Detergent –Algae CuSO4 d. Unit coolers
10
e. High pressure mist - fog –Small droplets Nozzles –150-200 psi up to 500 psi –special pump –Problems salt deposits poor air movement
11
Fog evaporative cooling
12
Compare pad and fan to fog cooling