ALTAIR ® 4X Multigas Detector It’s what’s inside that counts!
2
Our Vision of Safety Built on Durability – Based on tough Altair 4 Multigas Detector Powered by Performance – New High Performance XCell ™ Sensors
3
XCell Technology Typical life >= 4 Years – 60% longer sensor life than the industry average – Standard 3 year warranty XCell-erated response time, clear time, bump test – 38% faster response time than the industry average – Typical <= 15 seconds Typical cost of ownership savings > 50% – Longer sensor life and fast response – 50% less calibration gas used per minute than industry average Embedded microelectronics elevate performance – Each sensor has a microprocessor and digital output
4
Application Specific Integrated Circuit (ASIC) Industry 1 st ! Every XCell Sensor has an embedded ASIC! – Microprocessor, memory, and all circuitry to drive the sensor – Digital output Way beyond a “Smart Sensor” – Competitor’s “Smart Sensors” have a passive memory chip to store gas type, serial number, initial sensor settings, etc…. – The MSA ASIC drives the sensor, actively compensates the output, and coverts it into a digital signal. Benefit – Higher performing sensors with greater stability
5
XCell O2 Sensor Life Most Other O2 Sensors (Typical Life <= 2 years) – Use a consumable chemical reaction – Filled with lead which is converted to lead oxide – Sensor dies as lead is depleted (limited shelf life) XCell O2 Sensor (Typical Life >= 4 years) – Non-consuming chemical reaction (No lead) – O2 reduced to water and then oxidized back to O2 – Vastly increased shelf life
6
XCell Ex Sensor Life Most Other LEL Sensors (Typical Life = 2 years) – End of life caused by slow poisoning Poisoned by silicon, sulphur, or lead containing compounds – End of life can also result from a large physical shock XCell Ex Sensor (Typical Life = 4 years) – Two detectors double the active life of the sensor – Only one detector is catalytically active at a time – Metal alloy support rod added to increase durability
7
XCell CO/H2S Sensor Life Most Other CO/H2S Sensors (Life = 2-3 years) – Chemical poisoning of the electrode material – Loss of sensitivity due to electrolyte drying out XCell CO/H2S Sensor (Typical Life >= 4 years) – Increased active sites on electrodes Increase sensitivity Reduce the effects of poisoning – Robust carbon filter to protect the CO electrode – Expansion electrolyte well minimizes drying effect
8
Response Times Significantly Faster Than the Competition! Span Calibration: 60 sec Bump Test: < 15 sec Combustible sensor t90 <10 seconds (Methane) t90 <15 seconds (Pentane) Oxygen sensor t90 < 10 seconds CO sensor t90 < 15 seconds H2S sensor t90 < 15 seconds
9
XCell Sensor Designed and built by MSA – MSA IS Advancing Sensor Technology! – Our sensors are designed for OUR instruments! – We have the experts to support YOU!
10
Altair 4X Multigas Detector Personal 4-gas monitor – Detects O 2, H 2 S, CO, combustible gas – Rechargeable lithium-polymer battery Standard: – Event log – Full data log – Vibrating alarm – MotionAlert™ – InstantAlert™
11
Small Size Small, unobtrusive, lightweight design Easy to wear all day Alarms visible from 360º Fits in gloved hand One-handed operation Robust construction
12
Rugged Design Over-molded case design Built-in rubberized armor Impact shock protection – Withstands 20-foot drop Easy to grasp and hold Sealed against water/dust ingress to IP67 – Third-party tested – Dunk it in a bucket!
13
Multiple Alarms 95+ dB horn typical Multiple, alternating high-intensity alarm LEDs – On top and bottom of unit! Vibrating alarm is standard on all models InstantAlert ™ feature standard – Activates all alarms when desired MotionAlert ™ feature standard – If no motion is detected for 30 seconds, alarm sounds to alert others – Ideal for confined space entry
14
Provides Confidence Confidence signal – Green blinking Safe LED – Vibrating pulse – Confidence beep every 30 sec. to ensure operation Can be turned off – Setup mode
15
Advanced Features MSA exclusive MotionAlert™ feature – Indicates “man down” MSA exclusive InstantAlert™ feature – Activates all alarms when desired Most rugged instrument in its class – Withstands 20-foot drop Agency certified IP67 rating – Water and dust tight √ Bump checkmark √ (24 hrs) – Displays successful test result
16
Advanced Features Safe LED – Helps to ensures instrument’s proper operation Missing sensor alarm – Helps to prevent errors after service Password-protected setup mode – Controls unauthorized access Event & data log – >500 events and >50 hours MSA Link ™ Software-ready – Multi-language PC software to access records & change settings
17
Battery Lithium-polymer technology Virtually no memory effects Holds charge better Runs average of 24 hours – No need for multiple instruments during long shifts
18
Many Markets Oil and gas Chemical Fire Utilities Agriculture Construction Steel Water Various industrial applications
19
Start-up Performs diagnostic self-check – Display – 3 alarms – Sensor discovery Displays: – Instrument name – Software version – Combustible gas type – Toxic units (ppm or mg/m 3 ) – Alarm set points (Low, High, STEL, TWA) Operation similar to that of Altair 4 & Solaris ® Multigas Detectors:
20
Start Up Displays expected calibration gas concentrations Shows current time and date Indicates last successful cal. date Indicates next cal. date (if activated) Shows measurement countdown Offers fresh air setup option Defaults to measurement page
21
Pages Measurement (default) Bump Peak readings Minimum oxygen reading STEL for toxics (if activated) TWA for toxics (if activated) Time Date MotionAlert ™ feature
22
Data Log Event logging (500 events) – Gas and battery alarms – Calibration & bump records – Battery voltage – FAS, re-zero, calibration – Reset of TWA, STEL & Peak Gas records(>50 hours) – Reading – Time and date – Peak, Min, Average – Temperature Graphs & tables Infrared-based MSA Link Software-compatible – Change instrument settings Last successful calibration date
23
Setup Password-protected access Change: – Individual sensor channels – Combustible gas type – Auto calibration values – Calibration due on/off – Alarm set points – Low, High, STEL, TWA – Date – Time Other settings through MSA Link Software
24
Calibration Single-button auto cal-based – Access can be password-protected Same Altair 4 & Solaris ® Detector calibration cylinders – 1.45% CH 4 – 60 ppm CO – 15% O 2 – 20 ppm H 2 S 10048280 (34L) 10045035 (58L)
25
Calibration 1. Press and hold ▲ button 2. Instrument prompts user to “Zero Cal?” 3. Press to accept & initiate zero function – Or press ▲ to cancel function 4. Unit will automatically zero sensors – Zero pass 5. Instrument prompts user to “Span Cal?” 6. Attach cal. cap & flow cal. gas to instrument 7. Press to accept & initiate span – Or press ▲ to cancel function 8. Unit automatically spans sensors
26
Accessories Galaxy ® Automated Test System – Bump test and calibration – Record keeping QuickCheck ® Station – Bump test only – Records activities Charging cradle Multi-Unit Charger – Up to 10 instruments Universal pump probe
27
Low Maintenance Low level of end-user maintenance required: Separate sensors Sensor replacement kit Filter, gasket, etc. kit Front case with built-in filter Battery and electronics Most components available as replacement parts
28
Warranty Standard 3-year warranty – Sensors – Electronics – Battery Optional extended warranty – 1 year extra = 4 years total – Part of ATO!
29
Questions? Thanks!