Download presentation
1
To be more comfortable near vision life
Nikon “web.lens”
2
Complaint for reading glass
1.Complaint (survey in Japan market)
3
Complaint for progressive lens
1.Complaint for progressive (survey in Japan market)
4
Advantage of “PAL + web.lens” Dual Use
Vision of presbyopia Perfect Accommodation PAL Distance web.lens web.lens web.lens Intermediate Near -Any presbyope who loves progressives, but would love to benefit from an increased near and intermediate visual field. -Second pair market; think how much easier it is to cater to a customer when the second pair is as useful as the first one. Single Vision The Best Correction
5
Benefit of “web.lens” compare to PAL
Progressive ・ Wider near area ・ Natural Near Eye sight: Very close to the eye point ・ Small eye-ball rotation:easy to focus the pint
6
Proposal to wear PAL + “web.lens”
Do explain what is the benefit of each lens If your patient chose one lens --- You should always explain the benefit of another type If your patient want to buy reading glass--- You should always explain the benefit of “web.lens”
7
Sell more lenses and frames at the same time
How to sell web.lens 1. Up-graded reading glass Reading glass Nikon web.lens 2. Second multi-focal glasses Nikon Presio I + Nikon web.lens or Varilux Panamic + Nikon web.lens Sell more lenses and frames at the same time
8
Providing The Best Design
Web.lens Best matching for your desk work
9
web.lens design 10mm 4mm Degression Zone Wide Near Vision 5mm
10
Invariable Intermediate Zone
“web.lens” sight image Invariable Intermediate Zone Degression Zone Invariable Near Vision Zone
11
2 Materials and 2 Types
12
Choice of Type 2 STEP 1) Select according to addition value
2) Select according to specific needs
13
Alignment of web.lens < basic method>
14
Recommended height
15
Alignment of web.lens < PAL method>
16
Power on each point E.g.: near vision power 2.00D
17
AVAILABLE RANGE Index Product Power range Addition 1. 50
Nikon web.lens I +5.50 to –4.00 sph; cyl to combined power –8.00 Near to intermediate change 1.00D Nikon web.lens II Near to intermediate change 1.50D 1.67 Nikon web.lens I +5.50 to –8.00 sph; cyl to combined power –4.00 Near to intermediate change 1.00D Nikon web.lens II Near to intermediate change 1.50D Near to intermediate change 2.00D Nikon web.lens III
18
Recommend for the occupation
19
Recommend for the hobby
20
Case study
21
E.g. 55 Years(Perfect, accommodation 2D, add+2.00D)
In case of prescribing near point at 25cm Type 1 NP Stable intermediate +1.00D 100cm 33cm Far fitting Point +1.50D Near fitting Point +1.75D Near Point +2.00D 50cm 25cm Reading glass 25- 50cm NP ∞∞ 50 cm
22
E.g. 55 Years(Perfect, accommodation 2D, add+2.00D)
In case of prescribing near point at 25cm Type 2 NP 40cm 200cm Stable intermediate +0.50D Far fitting Point +1.25D Near fitting Point +1.625D Near Point +2.00D 25cm 50cm Reading glass 25- 50cm NP ∞∞ 50 cm
23
Improved Field of Vision
Web.lens Type1 25cm to 100 cm 25cm to 200 cm Web.lens Type2 < Case Study> 55 years old Reading glass 25cm to 50cm
24
SOLA Access Field of Vision
Web.lens Type1 Access A 25cm to 80 cm 25cm to 100 cm Access B Web.lens Type2 25cm to 133 cm 25cm to 200 cm
25
E.g. 65 Years(Perfect, accommodation 1.0D, add+3.00D)
In case of prescribing near point at 25cm Type 2 FP NP Stable intermediate 40cm +1.50D 67cm Far fitting Point +2.25D Near fitting Point +2.625D Near Point +3.00D 33cm 25cm Reading glass 25- 33cm NP ∞∞ 100 cm
26
Improved Field of Vision
Web.lens Type1 < Case Study> 65 years old Reading glass 25cm to 50 cm Web.lens Type2 25cm to 33cm 25cm to 100 cm
27
SOLA Access Field of Vision
Web.lens Type1 Access A 25cm to 44 cm 25cm to 50 cm Access B Web.lens Type2 25cm to 57 cm 25cm to 67 cm
28
Design comparison/ Astigmatism Line
Prescription ; S+2.00D SOLA Access B Web.lens type1 Web.lens Type2 Dirges; -1.25D Dirges; -1.00D Dirges; -1.50D
29
Design comparison/ Power Line
Prescription ; S+2.00D Web.lens type2 SOLA Access B Web.lens type1 Digres; -1.25D Digres; -1.00D Digres; -1.50D
30
Picture Yourself in Nikon lenses
WEB.LENS Trial Set Usage : To use trial frame which can adjust fitting point up-and-down, right-and-left. (1) Set this trial lens into trial frame a. Trial lenses should be set in front holder of trial frame b. Grip of the trial lens should be positioned at the ear-side upwards. Point a. must be adjusted on 90º of trial frame. Line b-c must be adjusted º line of trial frame. (2) adjust optical center with patient a. optical center must be fit with near P.D. b. optical center must be fit with near height Specifications : 3 engraved marks are on the rim. these engraved marks indicate fitting point and fitting height a a 1.00D R C b 19mm Picture Yourself in Nikon lenses
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.