Presentation is loading. Please wait.

Presentation is loading. Please wait.

3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical.

Similar presentations


Presentation on theme: "3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical."— Presentation transcript:

1 3200A Options / Technical Overview

2 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical Test Equipment Calibrates Insulation Testers, RCD Testers, Loop Testers, Multifunction Testers, PAT Testers, Flash & Breakdown Testers Transmille Ltd 1997 - 2011

3 3200A Feature Overview Transmille Ltd 1997 - 2011 FunctionComments Continuity Resistance SourceHI Accuracy Option Available Continuity Current Measurement Insulation resistance Source15kV Tester Option Insulation test Voltage Measurement16 th and 17 th Edition Compliant AC Voltage OutputContinuously Monitored RCD Test Time Measurement RCD Test Current MeasurementAuto Waveform Analysis RCD Test Duration Measurement Loop Resistance SourceAutoLoop Option PAT Earth BondSource Resistance & Measure Current to 30A PAT Leakage PAT Leakage Test Voltage Measurement PAT Load TestingOptional Adapter PAY Flash Voltage TestingOptional Adapter PAT Flash Crrent Testing

4 3200 Electrical Test Equipment Calibrator – Insulation Tester Calibration Calibrating Insulation testers with the 3200 is simple. All the functions required are in one instrument, making calibration fast and simple. Use with ProCal software to automate and save even more time.  Insulation Resistance from 100kohms to 10Gohms at 1kV  Measurement of Insulation Test Voltage at 1mA load  AC Voltage Calibration to 400 Volts  Continuity Resistance from 0 to 1kohms  Continuity Resistance Current to 300mA Measured into 1ohm

5 3200 Electrical Test Equipment Calibrator – RCD Testers Residual circuit breaker testers are designed to test and measure the break time of AC mains (RCD) trips at set test currents. Fault current is allowed to pass between live phase and earth. The ‘fault’ current is started by pressing a button on the tester, usually an LCD counter on the tester measures the time in milliseconds until the mains supply is disconnected. The 3200A has been specially designed to make the calibration of RCD testers safe & straight forward, which can otherwise be quite difficult and even dangerous. To calibrate an RCD tester, it is necessary to measure the current taken from the mains supply by the tester on each of its ranges and the time period measured shown on the testers display to the disconnection of supply. The 3200A can calibrate both functions. Intelligent firmware measures the correct fault current ignoring pre-test currents from testers such as the AVO CM500. The 3200A also provides accurate timed disconnection of the supply to verify the testers timing accuracy. Some RCD testers have additional functions such as which half cycle of the mains the fault current started, fault current duration etc. which can also be tested by the 3200A.

6 3200 Electrical Test Equipment Calibrator – Loop Tester Calibration To calibrate a Loop Tester simple connect to the 3200, select the loop function and run auto loop. Select the required loop value on the 3200 and press test. The 3200 automatically checks for a faulty loop tester before applying the full mains supply.  Automatic Measurement and compensation of supply loop impedance  Automatic detection of faulty Tester preventing damage to 3200  8 loop values from 0.05ohm to 1kohm.

7 3200 Electrical Test Equipment Calibrator – PAT Calibration There are several different measurement functions to be calibrated on a PAT tester. The functions required are all in the 3200 ensuring fast and efficient calibration of these instruments.  Earth Bond Resistance  Earth Bond Current Measurement to 30 Amps  Insulation resistance from 1M to 10Gohms  Leakage Current Measurement  Class 1 & 2 Flash Voltage Measurement

8 Increased Productivity Transmille Ltd 1997 - 2011 Reduced Test Times = Rapid Return On Investment

9 External Options Transmille Ltd 1997 - 2011 External HiPot/Breakdown option makes testing Breakdown testers fast and safe. EXTHV extends the resistance range of the 3200 to calibrate High Voltage insulation testers safely and without the need for expensive resistors

10 3200 Electrical Test Equipment Calibrator – HIPOT / Breakdown Tester Calibration  3kV & 12kV AC/DC Measurement Ranges  200uA 2mA 20mA Current Ranges  200uA : 5M  10M  20M  Loads  2mA : 500k  1M  2M  Loads  20mA : 50k  100k  200k  Loads  Current ranges : 1kV maximum  Power On & Overload Indicators  Requires 3200 Calibrator VOLTAGE MEASUREMENT  Connects between ground and appropriate voltage terminal  Select voltage range (3kV / 12kV AC/DC) and read back the voltage measured from the display of the 3200. CURRENT LOAD  Three electronically selectable ranges, nine current loads Select current range using the 3200 ‘softkeys’  Connect breakdown tester between ground and the appropriate resistor socket.

11 3200A vs 5320A Transmille Ltd 1997 - 2011 3200 is Easier to use – Electrical socket on front panel means direct connection for RCD and Loop Testers Extended Workload – Using the external options extend the workload of the 3200 Ultimate Portability – 3200 weighs only 10Kg, 5320A weighs almost double Lower cost of initial investment External HiPot/Breakdown box simulates loads as well as measures voltage


Download ppt "3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical."

Similar presentations


Ads by Google