SGI Confidential 7 - 1 System Cabling. SGI Confidential 7 - 2 Cable Labeling Conventions The cable labeling convention used in the COPAN 400 is as follows:

Similar presentations


Presentation on theme: "SGI Confidential 7 - 1 System Cabling. SGI Confidential 7 - 2 Cable Labeling Conventions The cable labeling convention used in the COPAN 400 is as follows:"— Presentation transcript:

1 SGI Confidential 7 - 1 System Cabling

2 SGI Confidential 7 - 2 Cable Labeling Conventions The cable labeling convention used in the COPAN 400 is as follows: Shelf SHx-SCy-FCz (x=shelf # =0,1,2,3,4,5,6,7, y=shelf controller # =0,1, z=Fiber Chanel port # = 0,1) SHx-SCy-NIC (x=0,1,2,3,4,5,6,7, y=0,1) SHx-DC (x=0,1,2,3,4,5,6,7) Application Processor APx-ETHy (x=0,1, y=0,1,2,3) APx-BMC (x=0,1) APx-PSy (x=0,1, y=1,2) Keyboard-Mouse-Video KVM-K KVM-V KVM-M KVM-PS Platform Service Manager KVM PSM-K = keyboard PSM-V = video PSM-M = mouse Platform Service Manager PSM-USBx (x =1,2,3,4) PSM-EMx (x = 0,1) PSM-RS232 PSM-PS Power Supply Status Monitor PSSM-USB1 Internal Network switch INET-Px (x=1 through 24) INET-PS

3 SGI Confidential 7 - 3 I/O Panel Rear View (Left Side)

4 SGI Confidential 7 - 4 I/O Panel Rear View (Right Side)

5 SGI Confidential 7 - 5 I/O Panel Labeling (1 of 2)

6 SGI Confidential 7 - 6 I/O Panel Labeling (2 of 2)

7 SGI Confidential 7 - 7 Cabinet Support Cabling (1 of 2) * The mounting location is in the right bracket assembly that supports the KVM at the front. ** The mounting location is in the IO Panel, marked as USB.

8 SGI Confidential 7 - 8 Cabinet Support Cabling (2 of 2)

9 SGI Confidential 7 - 9 Application Processor Support Cabling

10 SGI Confidential 7 - 10 8 Shelf SH0-SH3 Fibre Channel Cabling (1 of 4) For shelf cables, END 1 plugs into the shelf controller as labeled, end 2 plugs into the IO panel as labeled.

11 SGI Confidential 7 - 11 8 Shelf SH0-SH3 Fibre Channel Cabling (2 of 4) For shelf cables, END 1 plugs into the shelf controller as labeled, end 2 plugs into the IO panel as labeled.

12 SGI Confidential 7 - 12 8 Shelf SH4-SH7 Fibre Channel Cabling (3 of 4) For shelf cables, END 1 plugs into the shelf controller as labeled, end 2 plugs into the IO panel as labeled.

13 SGI Confidential 7 - 13 8 Shelf SH4-SH7 Fibre Channel Cabling (4 of 4) For shelf cables, END 1 plugs into the shelf controller as labeled, end 2 plugs into the IO panel as labeled.

14 SGI Confidential 7 - 14 6 Shelf SH4-SH7 Fibre Channel Cabling For shelf cables, END 1 plugs into the shelf controller as labeled, end 2 plugs into the IO panel as labeled.

15 SGI Confidential 7 - 15 8 Shelf Network Cabling Cables plug into shelf controller Ethernet port indicated on END 1 and Ethernet INET switch port indicated on END 2.

16 SGI Confidential 7 - 16 6 Shelf Network Cabling Cables plug into shelf controller Ethernet port indicated on END 1 and Ethernet INET switch port indicated on END 2.

17 SGI Confidential 7 - 17 VTL 8 Shelf Fibre Channel Cabling VTL 0 VTL 1

18 SGI Confidential 7 - 18 VTL 6 Shelf Fibre Channel Cabling VTL 0 VTL 1

19 SGI Confidential 7 - 19 Module Review Questions This completes the System Cabling module. Answer the review questions before proceeding. 01. Decode this cable label: SH3-SC0-FC1. 02. Decode this cable label: SH1-DC. 03. Decode this cable label: PSSM-USB1? 04. Decode this I/O Panel label: PSM-MGT ? 05. Decode this I/O Panel label: SVC Port-A ? 06. Decode this I/O Panel label: USB? 07. How do you get a KVM console on the AP?

20 SGI Confidential 7 - 20 Lab Project Using applicable service documentation, you will be given 20 minutes to: Examine cable labels on a production system + Ethernet cables + USB cables + Fibre channel cables + Power cables Trace cables from: + PSM to KVM, Network Switch, I/O Panel, and front of cabinet + Network switch to I/O Panel, SC, AP, PB + AP to I/O, Network Switch, SC + PB to PSM, KVM, AP, Shelf, and site power source Examine cable runs in the cabinet Examine cable bundles for components not installed in cabinet

21 SGI Confidential 7 - 21 21