Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit
2
GLASSWARE Griffin Beaker Erlenmeyer Flask Graduated Cylinder Graduated Pipet
3
GLASSWARE Griffin Beaker Approximate Graduations
4
GLASSWARE Erlenmeyer Flask Approximate Graduations
5
GLASSWARE Graduated Cylinder Used for Routine Volume Measurements of 25 mL or Greater
6
GLASSWARE Graduated Pipet Used for Routine Volume Measurements of 25 mL or Less Wide Tip Use When Solids in Sample
7
GLASSWARE Graduated Pipet NOT VOLUMETRIC Wide Tip Use When Solids in Sample
8
Volumetric Glassware Required for High Accuracy and Precision Required When Preparing or Using Standard Solutions
9
Volumetric Glassware Volumetric Transfer Pipet Accuracy and Precision Standard Solutions Buret Volumetric Flask
10
VOLUMETRIC GLASSWARE GLASSWARE Must Be Used Properly
11
BURET
12
To Deliver Calibration Temperature BURET
13
Completely Coat Inside Surface Rinse With Titrant
14
Not Clean Not Clean BeadsofLiquid
15
Rinse Three Times Fill to Above Top Graduation
16
Discharge All Air Bubbles
17
Drain Until Top of Liquid Is In Graduations
18
Curved Surface of Liquid MENISCUS
19
READER
20
X X O Proper Reading
21
Bottom of Meniscus to Top of Graduation
22
Increase Ten Graduations }
23
9.64 24.16
24
Record Initial Reading Add Indicator Proper Grip
25
Mix Well Near Endpoint
26
Split Drops Transfer To Flask Rinse Into Reaction
27
At Endpoint Read Record Final Reading Final Reading – Initial Reading = Volume Delivered
28
Properly Dispose Excess Properly Clean Air Dry
29
Proper Storage
30
Volumetric Transfer Pipets
31
OneCalibration ToDeliver CalibrationTemperature VolumetricTransferPipetsVolumetricTransferPipets
32
Fill By Vacuum
33
Fill By Vacuum Pipet Bulb Rinse
34
Must Drain Evenly Not Clean Not Clean
35
Fill Above Calibration Wipe Tip Drain To Calibration Touch Container To Remove Drop
36
Allow To Drain Touch Tip To Flask Some Will Remain In Tip
37
Exception ETCHED Ring NOT Painted FOR BLOW-OUT
38
Properly Clean Air Dry
39
Using Volumetric Pipets 1. Rinse with solution to be pipeted (Observe for even draining) 2. Fill to above graduation 3. Wipe off outside of pipet 4. Drain to graduation ( bottom of meniscus to top of graduation) 5. Touch tip to waste vessel 6. Transfer by gravity (vertical - don’t force) 7. Touch tip to inside of receiving flask (clean pipet)
40
Volumetric Flasks Volumetric Flasks
41
TC To Contain NOT Intended To Deliver
42
To Prepare Solutions With Accurately Known Concentration
43
Fill Half And Mix Fill To Below Graduation Fill Drop-wise To Calibration
44
Invert Rapidly
45
Transfer To Reagent Bottle Properly Clean Air Dry
46
Volumetric Glassware Volumetric Transfer Pipet Accuracy and Precision Standard Solutions Buret Volumetric Flask
47
Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit