Presentation is loading. Please wait.

Presentation is loading. Please wait.

Valor 1000 single-dual display models CP1-0 / September, 2009.

Similar presentations


Presentation on theme: "Valor 1000 single-dual display models CP1-0 / September, 2009."— Presentation transcript:

1 Valor 1000 single-dual display models CP1-0 / September, 2009

2 Internal usage only 1 Valor 1000 Series - UPDATE NOW with dual-display models: V11P-T NEW!

3 Internal usage only 2 Valor 1000 Series - Mission Compete in low cost dry food service/ portioning segment with simple, portable and low cost precision scale

4 Internal usage only 3 Valor 1000 Series - Concept Address New Markets…  Low cost Precision general weighing  Low cost compact food portioning With New Product….  Sleek profile, large backlit display, internal battery  Removable stainless steel pan, smooth housing  Bench or tabletop friendly footprint Deliver Ohaus Value  Good performance, good quality, low cost  Check and accumulate application modes  Competitive pricing vs. others

5 Internal usage only 4 Valor 1000 Series - USP’s Ergonomic design  Small footprint, mid height, large stainless pan  Bright easy-to-read backlit LCD (dual display models now available), with audible alarm Solid performance  Resolutions up to 7,500d  Level bubble and feet maximize accuracy  Digital external span calibration Friendly operation  Easy to clean, Easy transport size  Long life Standard Battery or AC power with auto shut off light  Simple Check weigh, and accumulate functions NEW!

6 Internal usage only 5 Valor 1000 Series - Std Features Standard Features  ABS plastic housing with SS pan  Weighing units: kg, lb, g, oz  Check weigh and Accumulate modes  Level bubble and adjustable feet  Four raised tactile mechanical buttons  Internal rechargeable ~80 hour lead acid battery  7-segment 6 digit backlit LCD (front / front-rear)  Stability indication, Auto zero tracking  Power saving auto shut off backlight  Subtractive Tare up to capacity  Power toggle switch  Low battery, over under accept indicators  AC power adapter

7 Internal usage only 6 Valor 1000 Series – Models/Apps V11P3 V11P3T V11P6 V11P6T V11P15 V11P15T V11P30 V11P30T 3kg x 0.5g6kg x 1g15kg x 2g30kg x 5g Applications General weigh Dry Portion Check weigh Production line Ingredient mixing NEW!

8 Internal usage only 7 Valor 1000 Series - Competition Valor 1000CAS SWA&D SKGram DV Capacities 3-30kg2-20kg1-30kg Resolution 7,500d (non apvd)2,000d apvd5000d (2000d apvd)11,000d (non apvd) Accessories SS Pan Housing ABS plastic, with level bubble and feet ABS Plastic with level bubble and feet ABS plastic, adjustable feet Display Blue Backlit LCD (front / front-rear) LCD Backlit LCD Power AC or Standard Lead acid Battery ~80 hours AC or battery 1000 hours for alkaline (not included) ~500 hours for manganese (not included) 6 'D' size batteries (not included) or AC Adapter (optional $22.00) AC or Standard Lead acid Battery ~200 hours Modes Weigh in lb,kg,oz,g Acc. Mode, Check weigh mode Weigh in lb,kg,oz,gWeigh in g,kg,lb, lb:ozWeigh in g only Approvals NoneNTEP None Other NoneSecond display optionSecond Display optionNone List Price Range ~$150-200$250~$270$250

9 Internal usage only 8 Valor 1000 Series – OH Positioning Valor 1000Valor 2000Valor 3000Valor 5000FD List Range $150-$200$220-$295$200-$395$350$395 Cap x Read 3gk x 0.5g3kg x 0.5g200g x 0.01g3kg x 0.5g 6kg x 1g 2000g x 0.1g6kg x 1g 15kg x 2g 30kg x 5g 3kg x 0.1g 6kg x 0.2g 15kgx 0.5g 30kg x 1g Housing ABS Plastic SSABS PlasticSS IP Rating NoneAll IP65Some IP65 Max d 7,500d 20,000d30,000d Units kg,lb,g,oz kg,lb,g,oz, lb:oz, dec oz, fr oz Display Backlit LCD (front / front-rear)LEDBacklit LCD Pan size Power AC and IR lead acid AC or 3 C batteryAC and IR lead acid Type Approvals NoneNTEP/OIML Certifications NoneNSF, USDA Modes Weigh, Check, Accumulateweigh Weigh, % S-gravity, Fl oz Weigh, Check with LED

10 Internal usage only 9 Valor 1000 Series– Contents Valor Box 1000 includes:  1x Scale  1x SS platform  1x AC adapter  1x 5 language operator manual

11 Internal usage only 10 Valor 1000 Series– Model Numbers V: Family ID (V for Valor) 1: Series level (1000 series) 1: Version 1= First version of Valor 1000 P: Housing Designator (X = Stainless steel, P= Plastic) X: kg Capacity Digit T: “T”wo display version V11PXTV11PXT NEW!

12 Internal usage only 11 Valor 1000 Series– Keypad ZERO (enter) Zero’s scale display not subtractive of capacity (Accept when used in menu, clears accumulated value when in accumulate) SELECT & M+ Change weighing units Kilograms (kg) Pounds (lb) Ounce (oz) Gram (g) M+ (up arrow) Add weight on pan for accumulate mode, when pan empty recall current stored weight (increments in menu) SELECT (left arrow) Used in conjunction with M+ to change weighing unit, used in conjunction with zero to enter check weigh mode (decrements in menu) TARE (down arrow) Subtracts value on pan from capacity (decrement size when used in menu)

13 Internal usage only 12 Valor 1000 Series– Setup Basics  Attach mains power  Charge battery 8-12 hours before use  Set on firm level surface, adjust feet for leveling  Calibrate scale before operating

14 Internal usage only 13 Valor 1000 Series– Setup Changing Units  Press M+ key and SELECT key to change unit of measure (g,kg,lb,oz) Backlight  Press and hold ZERO button until [b9---x] is displayed, where x= 0 = backlight is turned off 1 = backlight is on during weighing 2 = backlight is always on  Press TARE to change the setting. Press ZERO to confirm the setting and return to weighing.

15 Internal usage only 14 Valor 1000 Series– Setup Calibration………..Important  Default settings for divisions and decimal point should always be selected during calibration.  Changes not recommended.  Scale will not calibrate if divisions or decimal point is changed.  To restart, turn scale off and begin calibration again.

16 Internal usage only 15 Valor 1000 Series– Setup Calibration  Press and hold ZERO and SELECT during power on "SET--- " will be displayed. Short press the SELECT key until "SET-F1" is shown  Short press ZERO key to accept F1 and display "A____x” (x=divisions in grams). Short press ZERO key to accept the default division setting.  Short press ZERO key to accept and display "b____x” (x=decimal point). Short press ZERO key to accept decimal and display “C xxxxx”.

17 Internal usage only 16 Valor 1000 Series– Setup Calibration  Short press ZERO key to accept the default span calibration weight setting (short press M+ or TARE to increment or decrement)  Short press ZERO to accept calibration weight and display "dxxxx”. Short press ZERO key to accept the default setting  Short press ZERO and display will show "Load 0". Make sure pan is empty then short press ZERO key. Display will show "CAL 0" briefly, then "Load F”  Short press ZERO to display "Fxxxxx”. Put displayed weight on the scale, and short press ZERO to accept.

18 Internal usage only 17 Valor 1000 Series– Operation Basic Weigh  Turn on scale by flipping toggle switch under right side of scale  Segment check and serial number will be displayed  Keep pan clear and wait for stability and center of zero indicator.  Place container on scale and press Tare key.  Place object in container – net weight will be displayed, stability indicator will appear.

19 Internal usage only 18 Valor 1000 Series– Operation Check Weigh Use this mode to quickly compare samples to a specified tolerance range.  Press ZERO key to set the display to zero.  Place a sample on the pan and read the weight and under / accept / over status on display.  Scale will beep when weight is in tolerance or outside tolerance (user selectable setting)

20 Internal usage only 19 Valor 1000 Series– Operation Check Weigh (setup) Over and Under Limits  Press and hold ZERO and press SELECT until [SET---] is displayed.  Press SELECT to display [SET-F0]  Press SELECT to view the upper limit [000000].  Press , ,  to edit the upper limit.  Press ENTER to confirm the setting and display the lower limit [000000].  Press , ,  to edit the lower limit.  Press ENTER to confirm the lower setting and display the alarm setting [run__x],

21 Internal usage only 20 Valor 1000 Series– Operation Check Weigh (setup con’t)  X=0 Alarm and under / accept / over indicators are off.  X= 1 Under / accept / over indicators are displayed, alarm beeps when weight is outside accept range.  X= 2 Under / accept / over indicators are displayed, alarm beeps when weight is within accept range.  X=3 Under / accept / over indicators are displayed, alarm is off..  Press SELECT to change the alarm setting.  Press ENTER to confirm setting and display [End]  Press and hold ZERO key and press SELECT to return to weighing.

22 Internal usage only 21 Valor 1000 Series– Operation Accumulate  Press ZERO to set the display to zero.  Place the sample on the pan.  Press M+ to store the weight of the sample. Storage is confirmed by the display [n x], where n is the sample number.  Remove the sample and place the next sample on the pan and press M+. Σ Accumulate

23 Internal usage only 22 Valor 1000 Series– Operation Accumulate (con’t)  Repeat this process until all samples have been weighed.  Review the accumulation data by pressing M+ when the display is at zero.  The display first shows the number of samples [n x]  Press M+ to view the maximum sample weight [Hxxxxx].  Press M+ to view the minimum sample weight [Lxxxxx].  Press M+ to view the total sample weight [xxxxx]. Σ Accumulate

24 Internal usage only 23 Ohaus Solution:Customer Value:Customer Needs: Lightweight, battery powered- Up to 7,5000d resolution U S P Efficient, full ABS plastic design U S P Best of both worlds, low cost, yet Ohaus quality Low maintenance Trouble free operation Inexpensive, compact design Valor 1000 Series– Value Prop Portable with good performance Easy to keep clean and store after day of use Smooth shapes, no gaps, or ridges, removable pan, portable size Easy to transport, no power cord needed, precision accuracy U S P