MegaTronand MegaTrons SS Water Treatment’s Most User Friendly Web Capable Controllers
2
Menu and Keypad User friendly ATM menuUser friendly ATM menu 16 lines of information16 lines of information 20 button keypad20 button keypad Set everything from keypadSet everything from keypad
3
System Approach MegaTron “system” approach for 1 to 4 independent systemsMegaTron “system” approach for 1 to 4 independent systems MegaTron SS for single system controlMegaTron SS for single system control ConductivityConductivity TemperatureTemperature pHpH ORPORP 2 water meter inputs2 water meter inputs Flow switch inputFlow switch input 5 additional digital inputs5 additional digital inputs Up to 5 chemical feed timersUp to 5 chemical feed timers Make-up conductivity (on full size MegaTron)Make-up conductivity (on full size MegaTron)
4
Conductivity Control 1 Point Calibration1 Point Calibration Bleed Limit TimerBleed Limit Timer Cycles Control with Make-up ConductivityCycles Control with Make-up Conductivity Boiler sampling: Continuous, Timed, Sample and HoldBoiler sampling: Continuous, Timed, Sample and Hold
5
ORP and pH Set point control including individually set alarms and limit timersSet point control including individually set alarms and limit timers ORP interlocked with a 28-day timerORP interlocked with a 28-day timer pH feed interrupted by other chemical feed timerspH feed interrupted by other chemical feed timers LSI or RSI values displayedLSI or RSI values displayed
6
Chem Feed Timers Pulse Timer with AccumulatorPulse Timer with Accumulator Percent TimerPercent Timer Post Bleed % Timer with LimitPost Bleed % Timer with Limit Limit TimerLimit Timer 28-day Timer28-day Timer
7
Auxiliary Flow Meter Inputs Auxiliary flow meter inputs are available to track various flow meter devices like the FloTracker in a metering pump’s discharge line. Auxiliary flow meter inputs are available to track various flow meter devices like the FloTracker in a metering pump’s discharge line. Historically track chemical or water usage with low level alarms, no flow alarms for pump loss prime or no bleed off flow. Historically track chemical or water usage with low level alarms, no flow alarms for pump loss prime or no bleed off flow. Maintain a set PPM for chemical feed by tracking chemical cycles of concentration, make-up water and chemical addition. Maintain a set PPM for chemical feed by tracking chemical cycles of concentration, make-up water and chemical addition.
8
Relay Flexibility The main box holds up to 10 relays and the controller can control up to 20 relays with 11-20 housed in additional boxes.The main box holds up to 10 relays and the controller can control up to 20 relays with 11-20 housed in additional boxes. What activates each relay can be defined by the user from all of the available control functions on the unit. This means you can have pH monitoring but not have a relay assigned to it.What activates each relay can be defined by the user from all of the available control functions on the unit. This means you can have pH monitoring but not have a relay assigned to it. Multiple functions can be setMultiple functions can be set to activate a relay or force it off, allowing for special control logic.
9
Service Notepad Each of the up to 4 systems have 10 Service Notepad items for storing user entered data such as testing results that can have a user defined name, number range, unit of measure, high alarm, low alarm and time interval alarm for the next expected manually enter data. The Service Notepad can be used to enter manually tested readings like chemical residual, raw water chemistry, hand held tester readings into the MegaTron. The MegaTron will then keep a record of them for history reporting and alarming.
10
Water Meter Inputs Each system card can have 2 water meter inputs. Each will store the hourly average for the past 24 hours, the daily average for the past 60 days reviewable at the unit via the onboard history plus have a running total.Each system card can have 2 water meter inputs. Each will store the hourly average for the past 24 hours, the daily average for the past 60 days reviewable at the unit via the onboard history plus have a running total. Systems with two active water meter inputs can calculate evaporation with that value also stored in history.Systems with two active water meter inputs can calculate evaporation with that value also stored in history. The Units of Measure can be set for Gallons per Contact or Pulses per Gallon allowing for easy configuration for paddle wheel or contacting head meters.The Units of Measure can be set for Gallons per Contact or Pulses per Gallon allowing for easy configuration for paddle wheel or contacting head meters.
11
4-20 mA MegaTron units can have eight 4-20mA inputs and MegaTron SS three. All have a user defined unit of measure, number range, name, set point, high alarm and low alarm and can activate a relay.MegaTron units can have eight 4-20mA inputs and MegaTron SS three. All have a user defined unit of measure, number range, name, set point, high alarm and low alarm and can activate a relay. Common 4-20mA inputs are level, corrosion, fouling, flurometer and other special sensors or monitors.Common 4-20mA inputs are level, corrosion, fouling, flurometer and other special sensors or monitors. MegaTron can have up to six 4-20mA outputs, MegaTron SS three with the user selecting the source from all analog inputs.MegaTron can have up to six 4-20mA outputs, MegaTron SS three with the user selecting the source from all analog inputs.
12
Digital Inputs 1 Flow Switch input per system card. Choose activation (open / closed), limit probe alarm outputs to only when system has flow and select if timers can run with or without flow.1 Flow Switch input per system card. Choose activation (open / closed), limit probe alarm outputs to only when system has flow and select if timers can run with or without flow. 5 Digital Inputs can be given a custom name and can activate or deactivate relays.5 Digital Inputs can be given a custom name and can activate or deactivate relays.
13
Customization Customers can put in custom names for: UnitUnit SystemsSystems RelaysRelays Digital InputsDigital Inputs Notepad ItemsNotepad Items 4-20 mA Inputs4-20 mA Inputs
14
On Screen History See history graphs or logs on screen: Probe InputsProbe Inputs Water MetersWater Meters Daily EvaporationDaily Evaporation Alarm ActivationAlarm Activation Relay ActivationRelay Activation Keypad ActivityKeypad Activity
15
WebAdvantage and the World Wide Web Keep You in Constant Contact 128 Bit Encryption Server Security128 Bit Encryption Server Security Back-up Assured History StorageBack-up Assured History Storage No Proprietary Software to LoadNo Proprietary Software to Load Log in From Any Computer with Internet AccessLog in From Any Computer with Internet Access Email Notification of Alarm EventsEmail Notification of Alarm Events
16
Web Connections Options Ethernet card with a CAT 5 cable for static or DHCP internet connection.Ethernet card with a CAT 5 cable for static or DHCP internet connection. External cellular router connects back to the controller’s Ethernet card.External cellular router connects back to the controller’s Ethernet card. Built-in phone modem for dial-up Internet provider (ISP) like EarthLink and a phone line.Built-in phone modem for dial-up Internet provider (ISP) like EarthLink and a phone line. BACnetBACnet MODbusMODbus
17
Web Based Remote Monitoring One Step ConnectionOne Step Connection View Current ReadingsView Current Readings Change SettingsChange Settings Manage UsersManage Users History Graphs and LogsHistory Graphs and Logs Create Custom ReportsCreate Custom Reports Set-up Auto ReportingSet-up Auto Reporting
18
One Step Connection Use any Computer with Internet Access Use any Computer with Internet Access Summary Page Review Summary Page Review Pick From All of Your Units with One Connection Pick From All of Your Units with One Connection
19
Check Readings / Change Settings Review Current Conditions Review Current Conditions Change Any Setting Change Any Setting Enter Notepad or Service Report Data Enter Notepad or Service Report Data
20
Manager Users Set-up Access to Controllers Set-up Access to Controllers Manage Access Levels Manage Access Levels Manage Alarm Email Notifications Manage Alarm Email Notifications
21
eService or LXF Integration T3-Web Reports T3-Web Reports Activate our exporting Activate our exporting PIN number PIN number Daily data transfer Daily data transfer Instrument data displayed Instrument data displayed
22
History and Auto Reporting Create Custom Reports Create Custom Reports Establish Auto Report Intervals Establish Auto Report Intervals View Any Data View Any Data
23
Prefabricated Systems Convenient installation Convenient installation Professional appearance Professional appearance Customizable Customizable Saves time & money Saves time & money
24
Product Support Nine regional sales representatives Nine regional sales representatives Five factory based customer services representatives Five factory based customer services representatives IT and engineering support IT and engineering support Proprietary engineered features Proprietary engineered features 2-year replacement warranty on Advantage made products 2-year replacement warranty on Advantage made products We pay return shipping costs We pay return shipping costs Advantage support is the best in the industry!
25
MegaTronand MegaTron SS Water Treatment’s Most User Friendly Web Capable Controllers Any Questions?