MINIATURE ENGINEERING SYSTEMS GROUP MINIATURE CENTRIFUGAL COMPRESSOR TESTING Presented by Dipjyoti Acharya.

Similar presentations


Presentation on theme: "MINIATURE ENGINEERING SYSTEMS GROUP MINIATURE CENTRIFUGAL COMPRESSOR TESTING Presented by Dipjyoti Acharya."— Presentation transcript:

1 MINIATURE ENGINEERING SYSTEMS GROUP MINIATURE CENTRIFUGAL COMPRESSOR TESTING Presented by Dipjyoti Acharya

2 ASSEMBLY OF THE CENTRIFUGAL COMPRESSOR

3 SECTIONAL VIEW

4 REQUIRED DATA PROCESSING TEMPERATURE MEASUREMENT PRESSURE MEASUREMENT MASS FLOW RATE MEASUREMENT

5 LOCATION OF P,T SENSORS

6 Our Requirements: Operating ranges 1) P – Tranducers ( Differential ) Pressure Range : 13 to 26 psid 2) Mass flow meter Temperature range : 120  C to 170  C Pressure Range : 14.6 psi to 24 psi 3) Thermocouple and E-type Compensator Temperature range : 7  C to 127  C Precision : ± 2 to 3  C

7 SETRA SPECIFICATIONS Pressure Range: 0 psid to 100 psid Temperature Range: -18  C to 80  C Accuracy: ± 0.25 % FS

8 SIERRA Multivariable “Innova” Mass Flow Meter ( Vortex Flow / Venturi Tube ) SPECIFICATIONS Mass Flow Range : 3 to 8 g/s Temperature Range: - 40  C to 205  C Pressure Range: 30 to 1500 psi Accuracy: ± 1.0 % of mass flow rate Can provide 5 process parameters flow a single entry point

9 FUTURE WORK PURCHASE THE P-TRANSDUCER AND MASS FLOW METER FROM THE COMPANIES SET-UP AND TRIAL – RUN THE EXPERIMENT End of slide : THANK YOU