Blower Door Quickie Set-Up Guide.

Similar presentations


Presentation on theme: "Blower Door Quickie Set-Up Guide."— Presentation transcript:

1 Blower Door Quickie Set-Up Guide

2 RetroTec Blower Door Duct Tester DM-2 Meter

3

4

5 Color Coded Connections

6 Retrotec DM-2 will work with all of these devices

7 Input B Ref B Ref A Input A

8 Program your DM2 for Blower Door (or Duct Tester)
Turn Manometer ON Press On/Off button Press Exit button Set Up Manometer Press Setup button Arrow up or down to Device Setup, then press Enter Enable/disable Devices Highlight with up down arrows, right arrow clicks yes/no Select 1000 eliminate duct tester DU 200 for a dedicated blower door meter Hit EXIT once set up Scroll and select Mode Set Up press Enter Enable/Disable different tests Flow 50 Pa should be active: to change scroll to test pressure then press Enter. Change to desired pressure, then press Enter again. For Duct Tester change to 25 pa Exit, Exit to get to the main screen

9 N = .60 ( located in Setup ) Time = 1 second ( toggle Time Avg button) Zero = On ( toggle Auto Zero button)

10 Meter always wants to go back to default screen, always just press Exit to return to previous screen
You can change the Full Screen Timeout duration by pressing Setup and scroll down to Full Screen Timeout (15 seconds is a good start)

11 Check Devices Enabled Toggle Device to see what is enabled
Should display only the devices you want to use For Blower Door Retrotec 1000 Leave on screen, press Range/Config Scrolls through various Plates Make sure the setting matches actual equipment configuration Leave at this configuration, don’t need to press Enter Hint: to start your tests with a good guess at the correct Plate use the following flow ranges for Model 1000 Blower Door: Open = 5,600 cfm A = 4,000 cfm B = 3,000 cfm

12 Retrotec Blower Door Test Assumes DM-2 Set up for Blower Door Press ON Press Exit (to continue) Pressure and 50 Pressure (to 50 Pascals) Punch Buttons 5 and 0 Press Enter Press Exit Twice (to Stop Test)

13 Makes your meter much easier to use
NO for Duct Tester Yes for Blower Door

14

15 Toggle through Mode again to look at fields:
Press Mode Shows two channels A&B Toggle through Mode again to look at fields: Channels A & B Pressure / Flow Air Changes/Hour + volume ft3 to get meter to convert and display 50 (toggles between and actual flows) For a 2-Point Test, turn 50 off, then set speed to 25 to get the 25 and 50 values for the 2 Point Test

16

17 Change Volume Press Mode until volume is displayed
Press Enter volume Area Clears the current volume Enter new volume with number keys For air changes per hour use Ft3 (ELA would use ft2, enable ELA with Mode settings) Press Enter to save your input

18

19

20 Automatic Run Recommended
Once equipment is set up and meter settings are correct, it is recommended to run the fan speed through manometer Press Set Pressure Blower Door: Set Room Pressure Pa Press Enter The fan will respond automatically Be prepared!

21

22

23

24 Retrotec Blower Door Please confirm contents:
Large Case Fan + Plates Plate A Plate B Plate C-8 Fabric Door Panel + Fan Cover Power Cord Tubing: Red, Green, Blue (and extras) Tube Fittings Static Pressure Tap Door Panel Frame

25 Retrotec Blower Door Please confirm contents:
Meter Case DM-2 Meter Power Supply/Charger “Umbilical” Cord 8 – 3” black plugs for C-8 plate USB Cable Useful Forms + Handouts Manual

26 On-Site Equipment List
Smoke Tube TEC Exhaust Flow Meter Pressure Pan Foam Blocks Flashlight / Headlight Cordless Drill + Bits + Extra Battery Screw Drivers Vise Grips/Wrench “Duct” Tape Leatherman/Knife + Cardboard Ladder / Stool Calculator + Camera Booties + Tyvek Suit Trash Bags + Paper Towels