1 WELCOME TO THE TECHNICAL presentation OF Sc500

2 Technical specifications
VOLTAGE (V) 24 IP PROTECTION CLASS IP X4 INSULATION CLASS III RATED POWER (W) in working condition 500 BRUSH MOTOR POWER (W) 450 VACUUM MOTOR POWER (W) 280 Drive MOTOR POWER (W) 200 VACUUM (KPA) 760 mm H2O SOUND PRESSURE LEVEL (dB(A)) / silent mode 63 / 60 WATER FLOW (L/Min) max LEV4 2,8 TANK (L) SOLUTION / RECOVERY 45 / 45 BRUSH PRESSURE (KG) normal / extra-pressure 15 / 30 BRUSH SPEED (RPM) 155 BRUSH SIZE (MM) 530

3 CONTROL PANEL Grey Operator key - start display

4 Service menu YELLOW key – superuser Key include magnet inside:
grey key – 1 magnet = switch machine ON Yellow – 2 magnet = enter to service mode Voltage to EB2 sensor Key > 2,45 Key issue 2,18 – 2,45 Grey 1,23 – 2,18 Yellow < 1,23 PCB sensor issue To adjust: speed + speed -

5 Hour Meter Cumulated running time for each motor: Key ON
Traction motor Brush motor Vac motor Running time reset: keep pressed for 10sec + Total Traction motor Brush motor Vac motor

6 ADJUSTABLE PARAMETERS TABLE
Cod. Description Minimum Default setting Maximum CHM1 Percentage detergent concentration level 1 0.25 % (1:500) 3 % (1:33) CHM2 Percentage detergent concentration level 2 0.80 % (1:125) P1/P3 Solution level 1 in % of fixed level 3 following machine speed 0 % 25 % 100 % P2/P3 Solution level 2 in % of fixed level 3 following machine speed 50 % P3 Solution level 3 following machine speed 1,0 cl/m 3,0 cl/m 5,0 cl/m P4 Enabling level 4 activated 2,8 liters/min regardless speed OFF ON SPT Timer EcoFlex™ function 0 (disabled) 60 sec. 300 sec. XPRES Extra pressure enabling FVMIN Minimum speed forward FVMAX Maximum speed forward 10 % RVMAX Maximum speed backward 30 % BAT (**) Battery type on board (see tabel) 1 5 TOFF Time auto power off 600 sec. BRGH Display contrast 20 50 VRID Vacuum power level in silent mode 1 low 5 high RPM (*) Brush speed threshold activation in amp 9 RESET Resetting of all factory settings

7 ADJUSTABLE PARAMETERS TABLE - hidden
Go to RESET parameter, then press: Cod. Description Minimum Default setting Maximum TSERV Set timer (hour) to show the maintenance key on display 1000 AR Acceleration ramp (sec.) 0,5 sec. 1,5 sec. 5 sec. DR Deceleration ramp (sec.) 8 sec. IR Deceleration ramp in reverse (sec.) VS1 Brush motor threshold 1 20 A 30 A 50 A VS2 Brush motor threshold 2 40 A VDEAD Natural paddle dead band 0,0 V 0,1 V 1,0 V INOM Drive current nominal 10 A 15 A IMAX Drive current max 45 A TMAX Time allowed for IMAX 0 sec. 12 sec. 60 sec.

8 Error codes Errors are shown on display by ALARM XX + description
& repeated On the main PCB (EB1) by Nr of LED RED blinking (useful in case the display not functioning)

9 Error code (alarm) G - General Alarms F - Function Alarms
DESCRIPTION G2 Error EEPROM (internal EB1) G3 Fuse F1 G4 Battery low voltage G5 Battery over voltage (>32V) G6 Communication error with EB2 G7 Relay failure (internal EB1) F2 BRUSH motor amperometric protection (ref. parameter) F3 VACUUM motor amperometric protection (> 30A for T>10s) F4 DECK ACTUATOR over current F5 Brush/vac stage broken (internal EB1) F7 Over temperature function stage (>90°C) F8 BRUSH motor shortcircuit (> 150A for 0,002sec) F9 VACUUM motor shortcircuit (> 150A for 0,002sec) T2 Drive motor amperometric protection (ref. parameter) T3 Potentiometer input activated at key on (check paddle) T4 Potentiometer failure T5 Drive system power section damage (internal EB1) T6 Drive motor shortcircuit T7 Over temperature drive stage (>90°C) G - General Alarms F - Function Alarms T - Drive system alarms

10 CHASSIS SYSTEM PE solution tank has function of frame and hold 2 module: Front frame Transaxle Drive wheel Brush deck support lever Rear frame Castor wheel Squeegee support

11 BRUSH DECK removal

12 BRUSH DECK SYSTEM Brush motor supply voltage controlled by EB1 depending on the load: 24V when consumption is > 9 amps. 20V when consumption is < 9 amps. (adjustable by Superuser key) Brush motor rpm reduction advantage in light application: Less water splashing Less noise Less stress of the surface due to lower rpm Lower energy consumption New shape brush hub with 2 KEYS 5x30

13 BRUSH MOTOR ELECTRICAL INPUT CHECK
Supplier - AMER Motor 2800 rpm IP20 Easy replaceable carbon brushes Apply an ammeter on the cable, Check the motor electrical input is 3 to 4 20 V (without load) 13

14 Brush deck actuator removal

15 Actuator Supplier – SIR 3 position actuator:
Step 0 = retracted - mechanical end of stroke Step1 = intermediate mm (green LED) electronically adjusted Step2 = extended mm (red LED) mechanical end of stroke No adjustment required Max thrust load: 300 N Speed: 16mm/Sec No load current AMPS MAX:1A/24 Full load current AMPS: 3A/24 Stall Amps: 5,5A IP44

16 SOLUTION SYSTEM SOLENOID VALVE
The solution flow levels 1, 2 and 3 regulate the flow of the cleaning solution according to the speed of the machine keeping constant the amount of solution dispensed per square meter of cleaned floor. The level of reference flow is the level 3: according to the setting of the respective parameter P3, the opening time of the solenoid valve (and the detergent pump if present) is automatically adjusted so that the quantity of solution in centiliters per linear meter path is constant and equal to the value set in parameter. Level 4: 2,8 L/min full valve open, not controlled by speed. example level 1 2 3 1km/h 0,2 0,3 0,5 3km/h 0,4 0,8 1,5 5km/h 0,6 1,3 2,5 Centiliters per meter cleaned (constant) 0,75 Centiliters per square meter cleaned (Ø530 deck) 1,4 2,8 5,7 16

17 SOLUTION SYSTEM SOLENOID VALVE

18 Ecoflex Standard With machine from factory Option
kit installation instruction SPOT: +1 step water flow, brush pressure and detergent strength for 60 seconds (Adjustable by SPT parameter)

19 Ecoflex purge Switch on and keep pressed: The pump run one cycle of 30sec to flush the detergent residual

20 VACUUM SYSTEM VAC motor Is assembled into sound isolated box standard
MOTOR VACUUM 24V 280W Option MOTOR VACUUM 24V 450W

21 VACUUM SYSTEM Check the gasket condition and correct assembly sequence to secure the proper sealing Supplier - DOMEL No carbon brush replacement Apply an ammeter on the cable Check the motor electrical input is 13 to V . 21

22 Vac motor silent mode VAC motor supply voltage controlled by EB1 depending on silent mode selection: Vac motor rpm reduction advantage in light application: Lower sound level Enable cleaning in sound sensitive areas Lower energy consumption Set parameter VRID Vac motor voltage 1 (default) 16V 2 17V 3 18V 4 19V 5 20V

23 SQUEEGEE SYSTEM NEW plastic squeegee:
Easier and more stable squeegee installation ensure better cleaning performance and increased reliability NEW BLADES RETAINER Extremely easy to use blades installation and removal without any kind of tools Blades perfectly adhere with squeegee body and guarantee a better drying performance and stunning suction

24 Drive system New paddle Speed potentiometer 5K ohm
Resistor type potentiometer No adjustment required (neutral position set by spring inside potentiometer)

25 Drive motor New drive unit AMER Motor 200W @ 1300 rpm IP 44
Replaceable motor Replaceable carbon brush holder KIT Motor electrical input check: 5 - 7 A at 24V without load and maximum forward speed

26 Battery & onboard charger
Option on-board charger SPE Model: CBHD1-XR 24V - 13Amp high frequency Input: 85÷264 Vac, 50÷60 Hz PROTECTION GRADE: IP 30 Protection: against polarity inversion, short circuits, over-voltages, anomalies and thermal protection against overheating Option BATTERY PN Use per machine Description 2 BATT.12V-110Ah WET Tubular Monobloc BATT.12V-72Ah WET Tubular Monobloc BATT.12V-105Ah GEL Monobloc BATT.12V-76Ah GEL Monobloc BATT.12V-68Ah AGM spiralcell Max runtime up to 6/7h Machine overall consumption 11/12 amps (on smooth floor and silent mode)

27 Battery & charger curve selection
Type of battery value WET GEL / AGM generic 1 GEL EXIDE®/SONNENSHINE 2 GEL OPTIMA™ 3 GEL DISCOVER® 4 GEL FULLRIVER® 5 By the PARAMETER SETTINGS on control panel DEFAULT CHARGING CURVES: GEL / AGM generic (1) Voltage cut-off threshold WET GEL (maintenance free) 1 22 V 22,2 V LOW batt message 2 20,4 V 21,6 V OFF brush 3 19,4 V 20,6 V OFF VAC 4 18,4 V 19,6 V OFF drive

28 Charger error ERROR DESCRIPTION C1 CHARGER COMMUNICATION C2 BATTERY OVERVOLTAGE C3 CHARGER OVERTEMP C4 PHASE I TIME EXPIRED C5 PHASE II TIME EXPIRED C6 CHARGER FAULT Event memorized in ALARM LOG related to improper use of battery and/or battery charger: GB-N Time of continuous use with discharged batteries N= nr of hours machine ON with battery level below 20,4 (wet) or 21,6 (gel) GC Charging cycle interrupted before completion OBC disconnected before the phase IV GD-N Charging phase duration (<4h) N= nr of hours from start to phase II (if < 4h)

29 Main board (EB1) Drive motor (M3) F2 – low power fuse (3A)
F1 - Main fuse (100A) Inside PCB cover Vac motor (M2) Battery connection Brush motor (M1)

30 Main board (EB1) J1 – Detergent pump (M4) Deck actuator (M5)
J3 – connection to EB2 J4 – OBC communication J6 – ECOflex configuration: jumper on – ecoflex disabled J7 – trackclean J5 – solution level sensor J2 – solenoid valve (EV1)

31 Control board (eb2) membrane switch connections
speed potentiometer input Display power supply connection to EB1

32 Wiring diagram Solution level sensor (SW1)
Main board (EB1) manage directly: Brush motor (M1) Vac motor (M2) Drive motor (M3) Detergent pump (M4) Deck actuator (M5) Solenoid valve (EV1) CH – onboard charger * w/o onboard charger – jumper on EB4 – track clean (OPT) Solution level sensor (SW1) 32

33 END OF PRESENTATION QUESTION & COMMENTS? 33