Presentation is loading. Please wait.

Presentation is loading. Please wait.

Coal 2015 Strength Characteristics of Secura™ Hollow Groutable Cable Bolt ( HGC) Naj Aziz - UOW Robert Hawker - Orica Australia and Ali Mirza, Jan Nemcik,

Similar presentations


Presentation on theme: "Coal 2015 Strength Characteristics of Secura™ Hollow Groutable Cable Bolt ( HGC) Naj Aziz - UOW Robert Hawker - Orica Australia and Ali Mirza, Jan Nemcik,"— Presentation transcript:

1 Coal 2015 Strength Characteristics of Secura™ Hollow Groutable Cable Bolt ( HGC) Naj Aziz - UOW Robert Hawker - Orica Australia and Ali Mirza, Jan Nemcik, Xuwei Li, Haleh Rasekh February 11-13

2 Coal 2015 Outline Introduction Secura™ HGC Bolt Tensile Strength Test Single Shear Test Double Shear Test Conclusions February 11-13

3 Coal 2015February 11-13 Secura™ Hollow Groutable Cable bolt (HGC) Diameter: 30 mm Strands: 9 Cable Tensile Strength: 680 kN Strand Cross section Area (mm2)

4 Coal 2015February 11-13 a b Tensile Strength (BS7861-2, DEPT) (a)Tensile pull test set up and (b) snapped section of the cable bolt (b)Average Peak loads of 680kN from tests slightly exceed theoretical load from individual strand testing of 644kN)

5 Coal 2015February 11-13 b Tensile Strength Strand Failure All strands exhibited necking, cone and cup failures identifying uniform cable tensile loading

6 Coal 2015February 11-13 Single Shear Test (BS7861-2)

7 Coal 2015February 11-13 Load-displacement graphs of single shear tests Single Shear Test of Secura™ HGC

8 Coal 2015February 11-13 Single Shear Test of Secura™ HGC

9 Coal 2015February 11-13 Double Shear Testing

10 Coal 2015February 11-13

11 Coal 2015February 11-13 Test No 1: Shear load per face : 800 kN. Axial Load : 270 kN. Grout : FB400 Test No 2: Shear load per face : 772 kN. Axial Load : 97 kN. Grout: Carbothix DOUBLE SHEAR TESTS CONCRETE: 40 MPa

12 Coal 2015February 11-13 * Assumed 430 kN single shear result for ration reduction If 10 % allowed for concrete shearing force, then DS Test/ SS test will be 1.7 and 1.62

13 Coal 2015February 11-13 Conclusions Tensile failure loads slightly exceed theoretical combined strand loads indicating even load distribution for cable Single shear loads are 63% of Tensile Load Single shear testing of the cable bolt (based on BS7861 test procedure) yielded 40% lower load when compared to Double shear test The peak shear failure loads achieved using cement grout (FB400) and pumpable resin (Carbothix™) within same range Axial loads during shear testing within same range when using cement grout (FB400) and pumpable resin (Carbothix™) No cable rotation was detected in Tensile (DEPT) or double shear testing in either cable bolt

14 Coal 2015 TURKISH SOMO MINE DISASTAR -2014 ITU –Mining Department and the names of fatalities February 11-13 ?


Download ppt "Coal 2015 Strength Characteristics of Secura™ Hollow Groutable Cable Bolt ( HGC) Naj Aziz - UOW Robert Hawker - Orica Australia and Ali Mirza, Jan Nemcik,"

Similar presentations


Ads by Google