Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 Data Plane Summary Maarten Vissers 2012-01-18 v1.

Similar presentations


Presentation on theme: "1 Data Plane Summary Maarten Vissers 2012-01-18 v1."— Presentation transcript:

1 1 Data Plane Summary Maarten Vissers 2012-01-18 v1

2 2 Distributed Link Aggregation Data Plane Model

3 3 Link Aggregation Models – Partitioning 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 Aggregation Control Frame Collection Control prsr/mux Service Interface (UNITDATA) Aggr prsr/mux Marker Respndr Frame Collctr Frame Distribution Frame Distrbtr Marker Gen/Rec DAS Frame Switching Service Interface (UNITDATA) 19.2 6.7 802.3 19.2 6.7 802.3 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Rec DAS Frame Switching 8.5 8.6.3 MAC Relay (EISS) LACPDULACPDU Control prsr/mux Control plane focussed 802.1AX stack Data plane focussed p802.1AXbq stack (partitioned Link Aggregation shim) MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) Example Server Layer Alternatives: BVLAN,TESI LSP, ODUk Supports protected VLANs and unprotected VLANs

4 4 Link Aggregation server layers 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Rec DAS Frame Switching 8.5 8.6.3 MAC Relay (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) ODU Down MP 6.15 OTN Other LSP Down MP 6.15 MPLS Other VCn Down MP 6.15 SDH Other 6.14 6.10 6.14 6.11 19.2/5 Link TESI LSPODUkVC-n Link Aggregation server layers for Intra-DAS (virtual) link [Operator choice] 6.14 6.10 6.14 6.11 19.2/5 BVLAN (ISS) Link Aggregation server layer for ENNI link

5 5 ENNI DRNI SVLAN MEP/MIP Based on data plane model I in http://www.ieee802.org/1/files/public/docs2011/axbq-vissers-drni- data-plane-model-I-and-II-comparison-1011-v00.pptx http://www.ieee802.org/1/files/public/docs2011/axbq-vissers-drni- data-plane-model-I-and-II-comparison-1011-v00.pptx Characteristics are:  Single hop ENNI MA  NO MA end point on ENNI port

6 6 8.6.3 MAC Relay Two Node Portal with 2 x 1 ENNIs Normal state, no failures 8.6.3 MAC Relay 19.2/3/5 6.9, 9.5b Server Layer Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b Server Layer 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) Intra-DAS (virtual) Link ENNI1 ENNI2 SVID=5 SVID=6 Active SVID=6 MEPs/MIPsStandby SVID=6 MEPs/MIPs Active SVID=5 MEPs/MIPs Standby SVID=5 MEPs/MIPs NO MEP SP MIP ENNI MEP

7 7 8.6.3 MAC Relay Two Node Portal with 2 x 1 ENNIs Failure of ENNI2 link 8.6.3 MAC Relay 19.2/3/5 6.9, 9.5b Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) Intra-DAS Link ENNI1 ENNI2 SVID=5 SVID=6 X Deactivate those SVID=6 MEPs/MIPsActivate those SVID=6 MEPs/MIPs SVID=X (e.g. X=6) NO MEP function on ENNI1 and ENNI2 form one distributed NO MEP function SVID=X (e.g. X=6) SP MIP function on ENNI1 and ENNI2 form one distributed SP MIP function SVID=X (e.g. X=6) ENNI MEP function on ENNI1 and ENNI2 form one distributed ENNI MEP function NO MEP SP MIP ENNI MEP Server Layer

8 8 8.6.3 MAC Relay Two Node Portal with 2 x 2 ENNIs 8.6.3 MAC Relay 19.2/3/5 6.9, 9.5b Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) Intra-DAS Link ENNI1 ENNI3ENNI2ENNI4 SVID=X (e.g. X=6) NO MEPs, SP MIPs, ENNI MEPs (one set will be active, others will be standby) SVID=X (e.g. X=6) NO MEP function on ENNI1, ENNI2, ENNI3 and ENNI4 form one distributed NO MEP function SVID=X (e.g. X=6) SP MIP function on ENNI1, ENNI2, ENNI3 and ENNI4 form one distributed SP MIP function SVID=X (e.g. X=6) ENNI MEP function on ENNI1, ENNI2, ENNI3 and ENNI4 form one distributed ENNI MEP function NO MEP SP MIP ENNI MEP Server Layer

9 9 INNI DRNI SVLAN MEP/MIP Characteristics are:  No need for NO MEP  No need for ENNI MEP

10 10 8.6.3 MAC Relay Two Node Portal with 2 x 1 INNIs Normal state, no failures 8.6.3 MAC Relay 19.2/3/5 6.9, 9.5b Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) 19.2/3/5 6.9, 9.5b 19.2 6.7 802.3 Aggregation Control Frame Collection Marker Respndr Frame Collector Frame Distribution Frame Distributor Marker Gen/Re c DAS Frame Switching 8.5 (EISS) LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux 19.2/3/5 6.9, 9.5b 8.5 LACPDULACPDU Control prsr/mux MarkerMarker Aggr prsr/mux (EISS) Intra-DAS Link INNI1 INNI2 SVID=5 SVID=6 Active SVID=6 MIPStandby SVID=6 MIPs Active SVID=5 MIP Standby SVID=5 MIPs NO MIP Intra-Carrier DRNI: INNI ports do not have to support SVLAN Up MEPs and SVLAN Down MEPs Server Layer

11 11 DNP Data Plane Models BVLAN, TESI, SVLAN MEP/MIP Protection of EC groups  BVLAN restoration via MSTP/MVRP  TESI protection  TESI segment protection  Other server layer protection types comparable with TESI protection and TEST segment protection Protection of individual Ecs  G.8031 EC SNCP (EC segment protection)

12 12 Two Node Portal with BVLAN, TESI, SVLAN DNP 19.2/3/5 6.9, 9.5b 8.5 19.2 6.7 802.3 19.2/3/5 6.14 6.10 6.14 6.11, 9.5c 19.2/5 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 19.2/3/5 6.9, 9.5b 8.5 19.2 6.7 802.3 19.2/3/5 6.9, 9.5b 8.5 19.2 6.7 802.3 8.6.3 MAC Relay 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 19.2/3/5 6.9, 9.5b 8.5 19.2 6.7 802.3 19.2/3/5 6.14 6.10 6.14 6.11, 9.5c 19.2/5 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 19.2/3/5 6.9, 9.5b 8.5 19.2 6.7 802.3 19.2/3/5 6.9, 9.5b 8.5 19.2 6.7 802.3 8.6.3 MAC Relay 6.9 8.5 6.9 8.5 6.9 8.5 6.9 8.5 BVLAN or TESI BVLAN or TESI BVLAN or TESI BVLAN active blocked TESI


Download ppt "1 Data Plane Summary Maarten Vissers 2012-01-18 v1."

Similar presentations


Ads by Google