Download presentation
Presentation is loading. Please wait.
Published byEaster Butler Modified over 9 years ago
1
Laser-interferometer application to broadband observations Akito ARAYA (Earthquake Reseach Inst., Univ. of Tokyo, Japan) Broadband observation …. requires low-frequency sensitivity Advantages of Laser Interferometers: ・ high resolution owing to short wavelength of light ・ low drift using frequency-stabilized laser ・ in-situ calibration with reference to wavelength of light ・ free from EM noise or heating based on optical sensing ・ operation at high-temperature (deep underground)
2
Features of the laser-interferometric seismometer ・ Self calibration (with reference to the laser wavelength) Principle Block diagram
3
Features of the laser-interferometric seismometer ・ Laser-diode as a light source (l=850nm, 5mW) ・ Long-period pendulum (f 0 =7s with a 10-cm mass) Prototype laser seismometer Laser diode as a light source
4
Frequency response Features of the laser-interferometric seismometer ・ Wideband feedback (UGF=1kHz, phase delay < 0.2deg. below 100Hz)
5
Two calibration method were applied and both results were agreed well.
6
Comparison with an STS-2 seismometer ・ Accuracy of the self calibration ----- ~1% as compared with an STS-2 seismometer ・ Self-noise level ----- well below the Low Noise Model (50mHz ~ 100Hz) estimated from two identical laser seismometers Self-noise estimation (measured at Black Forest Obs.)
7
Current problems ---- thermal and barometric response
8
Optical-fiber-linked version of a laser seismometer (under development) Accelerometer (vertical) Accelerometer and an air-tight case No electronic components are installed in the accelerometer
9
Optical-fiber-linked borehole tiltmeter
10
A pendulum-type tiltmeter with laser interferometers
11
Test observation in an 80-m-deep borehole at Nokogiriyama observatory
12
Comparison with water-tube tiltmeters Earth tides ( 10 -7 ~ 10 - 6 rad ) Seiche (~ 10 -8 rad ) occurred in Uraga Channel (entrance of Tokyo Bay)
13
Earthquake observation Turkey earthquake ( 17 Aug. 1999 ) Initial motion -- (~ 10 -8 rad ) Maximum amplitude -- (~ 10 - 5 rad ) Rapid response than that of water-tube tiltmeters.
14
Laser strainmeter as a broadband seismometer ・ Iodine-stabilized Nd:YAG laser (l =532nm, dn/n=2×10 -13 ) ・ 100-m baseline, 1000-m underground (in Kamioka Mine)
15
Location of Kamioka Mine --- about 200km northwest of Tokyo
16
Map in the mine (-1000m level) L-shaped 100-m tunnel for laser strainmeters and a gravitational-wave detector Super KAMIOKANDE (neutrino detector)
17
Schematic diagram
18
Iodine-stabilized Nd:YAG laser
19
Optics in vacuum Twin bellows
20
Background noise level
21
Comparison with CMG seismometers
22
Tokachi earthquake (M=8.0) Excited free oscillation
23
Earth tides compared with predicted one
24
Summany Laser interferometer … promising method for ・ opening up a new window (deep borehole, ocean floor, etc.) optical-fiber-linked borehole seismometer, tiltmeter, and strainmeter ・ improving sensitivity long-baseline strainmeter with a highly-stabilized laser