1 Larson•Davis Sales Meeting 1999
HVM100 Human Vibration Meter This Great Stuff

2 The HVM100 The HVM100 is a handheld, multifunction, triaxial, integrating vibration meter. It performs digital sampling and filtering according to human vibration measurement standards. Multifunction operating modes: Vibration Severity measurements Hand-Arm measurements Whole-Body measurements Triaxial: Simultaneous XYZ measurements HVM100

3 Introduction Digital signal processor (DSP) based instrument
Vibration Severity, Hand-Arm and Whole-Body modes in one instrument Simultaneous three channel measurements: X,Y,Z and Sum () Single and double integration for velocity and displacement measurements Supports ICP mode, charge mode or direct input, lets you use any existing sensors (4 pin LEMO input connector adapter cables) Lightweight, rugged, hand-held instrument with 2x16 character LCD display Multi-lingual LCD display and printed reports HVM100

4 Introduction, cont. Overload and under-range detection
Three channels of user programmable AC or DC outputs Store/recall up to 10 user defined setups Store/recall up to 100 files with all metrics, on demand or at intervals of 1 minute to 99 hours Each file also stores 120/240 time history points (Arms with or without PEAK or Amin or Amax at a period of 1, 2, 5, 10, 20, 30, or 60 seconds) Fast kbps RS-232 serial interface for computer download or custom printing Conforms to: ISO 8041, 2631 Part 1 and 2, 5349 Part 1, and 10819 HVM100

5 Applications Vibration monitoring Industrial Hygiene
Human exposure to vibration from power tools and machinery (European Union Physical Agents Directive) Evaluation of vibration transmissibility of gloves (ISO 10819) Research & Development Product qualification (Machinery Directive Directive 89/392/EU) Improvement of products (safety and comfort) Evaluation of devices for vibration reduction HVM100

6 Effects of vibration on the human body
From CEN report CEN/TC 231 CEN = European Committee for Standardization Hand-transmitted vibration Vascular disorders (Vibration-induced White Finger “VWF” and Raynaud’s phenomenon) Neurological, Skeletal and Muscular disorders Whole-body vibration Low-back pain and back disorders Neck-shoulder disorders Digestive and Circulatory disorders Cochleo-vestibular and Reproductive effects HVM100

7 Customers cont. Occupational Organizations
Occupational health centers, Factory inspectors, Local authorities and Consultants Manufacturing and Construction Industries Manufacturers of machinery and components in transportation, agriculture and construction (Whole-Body) Manufacturers of hand tools (Hand-arm) Anyone interested in reducing, measuring or certifying the vibration of their product. HVM100

8 Metrics The HVM100 can measure:
Arms Linearly averaged acceleration (user specified linear integration time of 1, 2, 5, 10, 20, 30, or 60 seconds) Arms 1sec m/s2 WbX Amin Overall minimum RMS acceleration (based on Arms) Amin Amax WbX Amax Overall maximum RMS acceleration (based on Arms) Peak Short term maximum Peak acceleration (reset at the same rate as Arms) Peak Amp WbX Amp Overall maximum Peak acceleration HVM100

9 Metrics cont. The HVM100 can measure:
AeqN N=1,2,4 and 8 hour energy equivalent RMS acceleration Aeq Aeq WbX Aeq Aeq WbX CF Short term crest factor (ratio of Peak to Arms) CF CFmp WbX CFmp Overall crest factor, (ratio of Amp to Aeq) VDV Vibration Dose Value VDV 10:55:30 m/s4 WbX HVM100

10 Metrics cont. The Vibration Severity version (base model) of the HVM100 measures: Arms, Amin, Amax, Peak, Amp and Aeq The Hand-Arm option includes these additional measurements: Aeq1, Aeq2, Aeq4, and Aeq8 The Whole-Body option includes these additional measurements: CF, CFmp, and VDV HVM100

11 Standards ISO 8041: Human response to vibration -- Measuring instrumentation ISO : Mechanical vibration and shock -- Evaluation of human exposure to whole-body vibration -- Part 1: General requirements ISO : Evaluation of human exposure to whole-body vibration -- Part 2: Continuous and shock-induced vibrations in buildings (1 to 80 Hz) ISO 5349: Mechanical vibration -- Guidelines for the measurement and the assessment of human exposure to hand-transmitted vibration ISO 10819: Mechanical vibration and shock -- Hand-arm vibration -- Method for the measurement and evaluation of the vibration transmissibility of gloves at the palm of the hand HVM100

12 Standards cont. There are many other standards that specify the operating conditions of the devices to be measured. For example, ISO 8662 part 1 is the general standard for hand-held power tools, and parts 2-14 cover specific types of hand-held power tools. ISO :1988 Hand-held portable power tools -- Measurement of vibrations at the handle -- Part 1: General ISO : Chipping hammers and riveting hammers ISO : Rock drills and rotary hammers ISO : Grinders ISO : Pavement breakers and hammers for construction work ISO : Impact drills ISO : Wrenches, screwdrivers and nut runners with impact, impulse or ratchet action ISO : Polishers and rotary, orbital, or random orbital sanders ISO : Rammers ISO : Nibblers and shears ISO/DIS : Fastener driving tools ISO :Saws and files with reciprocating action and saws with oscillating or rotating action ISO : Die grinders ISO :Stone-working tools and needle scalers HVM100

13 Specifications Input Types: ICP mode, charge mode or direct
Input Range: 100 dB (in multiple ranges) Upper Limit: 100 m/s2 Lower Limit: m/s2 Range Gain: x1, x10, x100 or x1000 Calibration: Enter sensitivity or use calibrator Units: m/s2, cm/s2, ft/s2, in/s2, g, dB AC or DC Output for Each Channel: AC: Weighted or band-limited DC: Arms, Amax, Peak or  Arms HVM100

14 Specifications cont. Frequency weightings
Vibration Severity Mode: Ws (Severity) Fa (0.4 Hz to 100 Hz) Fb (0.4 Hz to 1250 Hz) Fc (6.3 Hz to 1250 Hz) Hand-Arm Mode: Wh (band-limited from 6.3 to 1250 Hz) Whole-Body Mode: Wc, Wd, Wj, Wk (band-limited from 0.4 to 100 Hz) WB (band-limited from 0.8 to 100 Hz) HVM100

15 Specifications cont. Peak accuracy: +/- 0.5 dB
Battery: 2 x AA (IEC Type LR6) Weight: 350 g (12.3 oz) Dimensions: 2.5cm x 7.5cm x 15cm (1” x 3” x 6”) Setups: Store up to 10 user setups Memory: 50 to 100 measurements, 1min to 99 hrs Time history: 120/240 samples of Arms with Peak or Amin or Amax, rate = 1, 2, 5, 10, 20, 30, 60 seconds Serial interface: RS232 on 8 pin DIN, up to kbps HVM100

16 Configuration Standard Items (included) Firmware Options
HVM100 Vibration Severity meter with memory for 50 files Accelerometer Cable Instruction manual Firmware Options Hand Arm Mode Whole Body Mode Memory for 100 Files HVM100

17 Configuration accessories
Accelerometers (not included) Seat accelerometer Single-axis accelerometers, small and medium Triaxial accelerometers, small and medium Mounting accessories and adapters (not included) Clamp connection (see ISO ) Hand-held adapter (see ISO ) Individually mounded adapter (see ISO and ISO 10819) Hand adapter Accessories for mounting accelerometers (mechanical filter, glue, studs, magnets, etc.) Building Support HVM100

18 Configuration accessories cont.
Clamp connection Hand-held adapter Hand adapter Individually mounded adapter Seat accelerometer HVM100