Download presentation
1
Cardiorespiratory Fitness
2
Cardiorespiratory Fitness Assessment
Purpose Determine level of fitness & set goals Develop safe & effective exercise prescription Document improvements Motivation Provide info concerning health status
3
Cardiorespiratory Fitness
Health Related Low levels ↑d risk of premature death ↑s reduction of death from all causes High levels high levels of PA & better health
4
Cardiorespiratory Fitness
Related to the ability to perform large muscle, dynamic, moderate-to-high intensity exercise for prolonged periods. Performance depends on Respiratory Cardiovascular Skeletal muscles
5
Measuring Cardiovascular Endurance (Aerobic Capacity)
Best Measure? VO2max O2 uptake – Pulmonary O2 transport – Cardiac O2 utilization - Muscular
6
Measuring Cardiovascular Endurance (Aerobic Capacity)
VO2max Measure Estimate Laboratory Tests Field Tests
8
Measuring Aerobic Capacity
Laboratory Methods Measures of Maximal Exercise Capacity Maximal Oxygen Consumption Submaximal estimations Astrand Rhyming Nomogram YMCA Cycle Protocol Discuss the various laboratory and field methods of assessing aerobic capacity. Focus on the reduction in reliability and validity that occurs when field tests are used, but note that they are much more feasible for mass testing.
9
Linear Relationships Among VO2, HR & Workload
. Illustrate that heart rate for a given workload can be used to estimate VO2. Also mention that as workload increases, VO2 increases.
10
Measuring Aerobic Capacity
Field Methods Distance runs 1 Mile Run 1.5 Mile Run 12 Minute Run 6 Minute Walk Rockport 1-Mile Walk Test Discuss the various laboratory and field methods of assessing aerobic capacity. Focus on the reduction in reliability and validity that occurs when field tests are used, but note that they are much more feasible for mass testing.
11
Measuring Aerobic Capacity
Field Methods Step tests YMCA 3-Minute Step Test Predicting VO2max w/o exercise VO2max = * self-reported physical activity – * age in yrs & %Fat * gender (female = 0; male = 1) Discuss the various laboratory and field methods of assessing aerobic capacity. Focus on the reduction in reliability and validity that occurs when field tests are used, but note that they are much more feasible for mass testing.
12
Measuring Aerobic Capacity Advantages/Disadvantages??
Laboratory Tests Vs. Field Methods Advantages/Disadvantages?? Discuss the various laboratory and field methods of assessing aerobic capacity. Focus on the reduction in reliability and validity that occurs when field tests are used, but note that they are much more feasible for mass testing.
13
Cardiorespiratory Fitness
Which test? Time demands Expense or costs Personnel needed (i.e., qualifications) Equipment & facilities needed Physician supervision needed Population tested (safety concerns) Need for accuracy of data
14
Cardiorespiratory Fitness
Field or Submaximal Tests advantages Less expensive Does not need same level of clinical supervision Lower risk Less sensitive & specific for disease detection Less equipment Generally shorter In lab tests can assess a workload progression Estimates of VO2
15
Cardiorespiratory Fitness
Field or Submaximal Tests disadvantages Maximum measures estimated VO2max prediction error can be 10-20% Limited diagnostic capabilities Limited for exercise prescription
16
Standard Procedures (must be followed)
Standard testing protocol Same modality & protocol – repeat testing Constant pedal rate Seat height Time of day Data collection standardized & consistent Subjects free of infection – normal sinus rhythm Pre test instructions Room Temperature (64-68O) – air flow
17
Assumptions of Submax Tests
Measurements made in steady state Linear relationship b/n HR & VO2 HRmax similar at same age Mechanical efficiency same
18
Indications for Stopping an Exercise Test in Low-Risk Adults
Angina-like symptoms Drop (20 mmHg) in systolic BP or a failure to rise Excessive rise in BP systolic pressure > 260 mmHg diastolic pressure > 115 mmHg Signs of poor perfusion light-headedness, confusion, ataxia, pallor, cyanosis, nausea, or cold & clammy skin
19
Indications for Stopping an Exercise Test in Low-Risk Adults
Failure of heart rate to ↑ Noticeable Δ in heart rhythm Subject requests to stop Physical or verbal manifestations of severe fatigue Failure of the testing equipment
20
Measuring Aerobic Capacity
Criterion Based Reference Minimal levels of aerobic capacity associated with a reduced risk of disease & death Females = VO2max of 31.5 ml/kg/min Males = VO2max of 35.0 ml/kg/min Norm Based Reference
21
Cardiorespiratory Fitness
Field Tests Complete a measured distance Distance covered in a certain time Submaximal Tests Step test Single or multiple stage cycle test HR measure Maximal Exertion Graded or progressive exertion to volitional fatigue (measure)
22
Pre-Test Considerations
Abstain from eating prior (>4 hrs) Abstain from strenuous exercise (> 24 hrs) Abstain form caffeine (>12-24 hrs) Abstain from nicotine (> 3 hrs) Abstain from alcohol (> 24 hrs) Medications
23
Step Tests Queens College or McArdle Step Test
Step: ht = in for 3 min Men: 24 steps/min; Women: 22 steps/min Radial pulse in 1st-5 sec, for 15 sec Men: VO2max = – (0.42 * HR) Women: VO2max = – ( * HR)
24
1.5 Mile Run Record total time to complete 1.5 miles
VO2max = /time Time in nearest hundredth of min
25
12 Min Walk/Run Cover maximum distance in 12 min
VO2max = (3.126 * meters)
26
Submaximal Cycle Ergometer Advantages
Non-weight bearing Accurate workloads Easy to measure HR & BP Cost is lower than treadmill Requires smaller space No electricity needed
27
Submaximal Cycle Ergometer Disadvantages
Non-familiar work mode Must maintain cadence Leg fatigue
28
Submaximal Prediction of CRF - Assumptions
B/n HR of HRmax = 220-age Steady State Constant cadence
29
Submaximal Prediction of CRF – Sources of Error
HRmax Efficiency Calibration Accurate measurement of HR HR at steady state
30
Cycle Ergometer Protocols (other)
Astrand-Rhyming Cycle Ergometer Test Single Stage Test – 6 minutes Males – unconditioned: 300 or 600 kgm/min (50 or 100 watts) Males – conditioned: 600 or 900 kgm/min (100 or 150 watts) Females – unconditioned: 300 or 450 kgm/min (50 or 75 watts) Females – conditioned: 450 or 600 kgm/min (75 or 100 watts)
31
Cycle Ergometer Protocols (other)
Astrand-Rhyming Cycle Ergometer Test (cont) 50 rpm Goal – HR b/n 125 to 170 – measured during 5th & 6th minutes – average the 2 HRs for nomogram Nomogram – page 73 (Figure 4-1) Age adjustment – page 72
32
Treadmill Testing Not usually used for submaximal testing
Range of efficiencies is so high Would not recommend – but can be done
33
Step Tests Astrand-Rhyming YMCA Protocol
Single step height – 33 cm for women, 40 cm for men Rate = 22.5 steps/min for 6 minutes YMCA Protocol 12 in – 24 steps/min 1 min - Recovery heart rate
34
Field Tests Rockport 1-mile walk Test 1.5-mile run test HR at end
VO2max (ml/kg/min) = – 0.17 (body mass in kg) – 0.39 (age in yrs) (gender) (time in min) – 0.16 (HR) 1.5-mile run test VO2max (ml/kg/min) = /(time in min)