Download presentation
Presentation is loading. Please wait.
Published byAmberly Bond Modified over 9 years ago
1
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
2
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 2 General
3
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 3 General (Cont.)
4
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 4 General (Cont.) The power cabinet is responsible for the following functions: Supplying voltages & controlling the UV lamp system Supplying voltages & controlling the cooler unit Supplying voltages & controlling the extraction unit
5
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 5 General (Cont.) Wiring Notes: Blue wire: 24VDC Red wire: 110VAC Black wire 400VAC
6
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 6 Units Description Earth Leakage Relay Electro Magnetic Compatibility Filter A1.1 Q1.1 -Mains circuit breaker Q2 -Transformer breaker K2-UV Main Contactor
7
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 7 Units Description (cont.) Safety Switch Relay K9: Verify that the UV lamphead cover is closed and enables the UV main contactor K2.
8
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 8 Fuses F1: 110 V out from the transformer, 2 Amps fuse F2: 24VDC power supply output protection, 2 Amps fuse F3: Shutter open signal to the shutter valve, 1.6 Amps fuse Fuses
9
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 9 Safety Relays Shutter Open Shutter Close 1 Shutter Close 2 Over Tem’ (Lamp) Lamp pressure E.M Contact 1&2 Fusses
10
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 10 Units Description (cont.) UV lamp High Voltage contactors: Enable the high voltage to the lamp by levels (30%-100%). K3K4K5.1K5.2
11
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 11 Units Description (cont.) Overload Relays: Q6.11 - Cooler Pump Q6.12 - Cooler Fan1 Q6.22 - Cooler Fan2 Q7 - Extract Fan Frequency Inverter A7 Contactors: K6.11-Cooler Pump Contactor K6.12-Cooler Fan1 Contactor K6.22-Cooler Fan2 Contactor
12
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 12 Extraction Fan Frequency Inverter A7 Units Description (cont.) Extraction fan frequency inverter A7: Controls the air extraction flow rate, depending on the UV lamp power.
13
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 13 Units Description (cont.) PLC Panel
14
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 14 PLC Panel Inputs: R1: Shutter ON, from the machine R3, R4 and R5: UV power bits, from the machine R6: Extraction fan operation indication, from A7 (Inverter)
15
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 15 PLC Panel (Cont.) Inputs: R7: Cooler pump or cooler fans trip indication R8: Lamp head pressure switch, from the UV lamp head R9: Lamp head cover status (closed/opened) indication R10: Transformer Contactor Operation K2 R12: Alarm reset button V2: 24VDC 0VD: 0VDC
16
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 16 PLC Panel (Cont.) Inputs and outputs: I1: Transformer breaker I2: Shutter opened indication, from the UV lamphead I3: Shutter closed indication, from the UV lamphead I4: Lamp head over temperature indication
17
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 17 PLC Panel (Cont.) Inputs and outputs (cont.): I5: Emergency switch from the machine I6: Cooler over temperature indication, from the thermal switch in the Cooler I7: UV lamp power indication I9: Cooler low level indication I10: UV ON signal from the machine 0VD: 0VDC QA1: Output signal to the extraction fan frequency inverter A7
18
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 18 PLC Panel (Cont.) Outputs: Q1: Extraction fan frequency inverter A7 Q2: Operating power to the UV main contactor K2 Q3, Q4 and Q5: Output power for enabling the high voltage contactors Q6: Enabling cooler pump and fans
19
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 19 PLC Panel (Cont.) Outputs Signals: S1: UV ready signal to the machine S2: Shutter open signal to the shutter valve S3, S4 and S5: UV fault signal to the machine
20
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 20 Transformer Receives an input of 380-480VAC. Converts the voltage to 110VAC.
21
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 21 24VDC Power Supply Receives an input voltage of 110VAC. Converts the voltage to 24VDC for the PLC.
22
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 22 High Voltage Transformer Receives an input voltage of 230VAC. Converts the voltage to 2000VAC for the UV lamp.
23
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 23 Capacitors Supply the high voltage to the UV lamp
24
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 Confidential 24 Electrical Connections XPC1: Connected to the cooler. XPC2: Connected to the cooler. XPPT: Connected to the UV lamp head. XPF7: Connected to the extraction fan.