Presentation is loading. Please wait.

Presentation is loading. Please wait.

Low Pressure, Continuous Flow Breathing Air System.

Similar presentations


Presentation on theme: "Low Pressure, Continuous Flow Breathing Air System."— Presentation transcript:

1 Low Pressure, Continuous Flow Breathing Air System

2 Common Challenges JOB REQUIREMENTS CONCERNS Supply breathing air to large workforce Supply breathing air 24 hrs/day High air usage Long duration projects Ease of operation Air quality Tight working area Hex-Chrome exposure for welders Breathing air delivery temperature Back-up compressors and back-up power supply for emergencies

3 King Air™ - Continuous Flow Breathing Air System Able to support large crews with Grade D breathing air. Ideal for projects with large air volume usage. Its dual-compressor design ensures air supply is not affected due to compressor malfunction.

4 Equipment design Chiller/Filter system Continuous flow compressor Dual compressor design which allows compressor switch in the event of a failure. 250 cfm @125 psi breathing air system Low pressure alarm. Filtration and in-line four-gas monitor ensure grade D breathing air. Automatic shut off if the gas monitor is triggered. Chiller reduces air temperature for comfortable breathing.

5 Equipment design Knock out pots Volume tanks (138gal) Distribution tanks (11gal) Low Pressure Manifold 2” SS Camlock quick disconnect lines

6 Key Benefits Continuous, cool, clean, high volume air supply. Easy to transport, deploy, operate and decommission. Emergency backup in the event of compressor failure. Eliminates the need for refill or equipment switch, streamlining operations. Suitable for large volume requirements and large distances from air supply. Versatile to accommodate various applications.

7 Technical Specifications DescriptionTechnical Specifications 250 cfm breathing air at 125 pslAir Capacity Filter system and in-line four-gas monitor producing Grade D breathing airAir Quality System LP alarm and four-gas continuous flow emergency shut offAlarms Dual compressor provides 100% redundancy for emergency backup. Additional safety backup can be provided by 12 packs or Air Qube™ Back Up Volume tanks (138gal) and distribution tanks (11gal)Tanks 480 V/3 PH/100 A ServicePower Requirements Low pressure breathing manifold has connections for five personnel, regulator and gauges Low Pressure Manifold Designed to operate with doors closed resulting in low noise level (<70 dBa)Noise Level King Air is fitted in a standard shipping container measuring 20 x 8 ft., mounted on a 30 x 10 ft. Gooseneck trailer making the King Air easy to transport Measures

8 Thank you


Download ppt "Low Pressure, Continuous Flow Breathing Air System."

Similar presentations


Ads by Google