1 Experts in Chem-Feed and Water Treatment Business Unit Measuring and Control Technology M&C Packages for the year 2015 Valid from 1 st January 2015 Rev. 008 Thomas Koetzing Dietmar BergerDr. Thomas Winkler Product Manager Business Unit Measuring & Control Technology E-Mail d.berger@prominent.de, Phone +49 6221 842-536d.berger@prominent.de Cell +49 174 3255 291 Please inquire for more detailed information about different versions of the packages Version: 26 November 2014. Prices valid until end of 2015 NEW: Now with inductive conductivity

2 Experts in Chem-Feed and Water Treatment Basic Package pH & ORP with Compact Controller A. Basic package pH & ORP with Compact Controller Standard prices, result in net price for ≥ 10 units220 € each < 10 units260 € each panel mounting adaptor14 € each PN 1037273 Basic pH & ORP PackagesNow Standard Prices !* * Net prices for 2015, ex works ProMinent Heidelberg ** or fixed cable sensors, if available Compact Controller pH / ORP (DCCa W 00 6 PR 0 01 0 EN) Adaptor DN 20, PP, R 1/2" (PN 1001834) Coax cable, 5m-S, SN6 open end (PN 1024107) pre-assembled PHES, PHER RHES, RHER (PHEX, RHEX +15 €) ** always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output !!With pH and ORP max. 10 m cable length!!  1 remote pause input  Wide range power supply 100 – 240 VAC  Sensor check for pH

3 Experts in Chem-Feed and Water Treatment Basic Package pH & ORP with Compact Controller A1. Basic package pH & ORP with Compact Controller Standard prices, result in net price for ≥ 10 units235 € each < 10 units275 € each panel mounting adaptor14 € each PN 1037273 Basic pH & ORP PackagesNow Standard Prices !* * Net prices for 2015, ex works ProMinent Heidelberg ** or fixed cable sensors, if available Compact Controller pH / ORP (DCCa W 00 6 PR 0 01 0 EN) Adaptor DN 20, PP, R 1/2" (PN 1001834) PHES, PHER RHES, RHER (PHEX, RHEX +15 €) ** always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output Coax cable, 10m-S, SN6 open end (PN 305040) !!With pH and ORP max. 10 m cable length!!  1 remote pause input  Wide range power supply 100 – 240 VAC  Sensor check for pH

4 Experts in Chem-Feed and Water Treatment Basic Package pH & ORP with Compact Controller B. Basic package pH & ORP with Compact Controller Basic pH & ORP Packages Compact Controller pH / ORP (DCCa W 00 6 PR 0 01 0 EN) Bypass aramtur DGMa110T000 Coax cable, 5m-S, SN6 open end (PN 1024107) pre-assembled PHES, PHER RHES, RHER (PHEX, RHEX +15 € Standard prices, result in net price for ≥ 10 units299 € each < 10 units340 € each panel mounting adaptor14 € each PN 1037273 Now Standard Prices !* always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output * Net prices for 2015, ex works ProMinent Heidelberg ** or fixed cable sensors, if available !!With pH and ORP max. 10 m cable length!!  1 remote pause input  Wide range power supply 100 – 240 VAC  Sensor check for pH

5 Experts in Chem-Feed and Water Treatment Standard Package pH & ORP with D1Cb Controller Standard prices, result in net price for ≥ 10 units377 € each < 10 units417 € each The D1C controller has a general ID code. Measured variable and language has to be chosen during start-up: Advantage: The controller can be used for all measurements Standard pH & ORP PackagesNow Standard Prices !* D1CBW00601000V0101 1G2200 Adaptor DN 20, PP, R 1/2" (PN 1001834) Coax cable, 5m-S, SN6 open end (PN 1024107) pre-assembled PHES, PHER RHES, RHER (PHEX, RHEX +15 €) always included:  2-way PID control  2 power relay  2 frequency relay  1 Alarm relay  1 mA output C. Standard package pH & ORP with D1Cb controller * Net prices for 2015, ex works ProMinent Heidelberg ** or fixed cable sensors, if available !!With pH and ORP max. 10 m cable length!!  1 remote pause input  Wide range power supply 100 – 240 VAC  Sensor check for pH

6 Experts in Chem-Feed and Water Treatment Standard Package pH & ORP with D1Cc Controller C_1. Standard package pH & ORP with D1Cc controller Standard pH & ORP Packages Coax cable, 10m-S, SN6 open end (PN 305040) PHES, PHER RHES, RHER (PHEX, RHEX +15 €) Standard prices, result in net price for ≥ 10 units423 € each < 10 units463 € each The D1C controller has a general ID code. Measured variable and language has to be chosen during start-up: Advantage: The controller can be used for all measurements Now Standard Prices !* D1CCD00601000V0101 1G2200 always included:  2-way PID control  2 power relay  2 frequency relay  1 Alarm relay  1 mA output Adaptor DN 20, PP, R 1/2" (PN 1001834) * Net prices for 2015, ex works ProMinent Heidelberg ** or fixed cable sensors, if available !!With pH and ORP max. 10 m cable length!!  1 remote pause input  Wide range power supply 100 – 240 VAC  Sensor check for pH

7 Experts in Chem-Feed and Water Treatment Standard Package pH & ORP with D1Cb Controller D. Standard package pH & ORP with D1Cb controller Standard pH & ORP Packages Bypass aramtur DGMa110T000 Coax cable, 5m-S, SN6 open end (PN 1024107) pre-assembled PHES, PHER RHES, RHER (PHEX, RHEX +15 €) Standard prices, result in net price for ≥ 10 units457 € each < 10 units497 € each The D1C controller has a general ID code. Measured variable and language has to be chosen during start-up: Advantage: The controller can be used for all measurements Now Standard Prices !* D1CBW00601000V0101 1G2200 always included:  2-way PID control  2 power relay  2 frequency relay  1 Alarm relay  1 mA output * Net prices for 2015, ex works ProMinent Heidelberg ** or fixed cable sensors, if available !!With pH and ORP max. 10 m cable length!!  1 remote pause input  Wide range power supply 100 – 240 VAC  Sensor check for pH

8 Experts in Chem-Feed and Water Treatment Standard Package pH & ORP with D1Cc Controller D_1. Standard package pH & ORP with D1Cc controller Standard pH & ORP Packages Bypass aramtur DGMa110T000 Coax cable, 10m-S, SN6 open end (PN 305040) PHES, PHER RHES, RHER (PHEX, RHEX +15 €) Standard prices, result in net price for ≥ 10 units502 € each < 10 units542 € each The D1C controller has a general ID code. Measured variable and language has to be chosen during start-up: Advantage: The controller can be used for all measurements Now Standard Prices !* D1CCD00601000V0101 1G2200 always included:  2-way PID control  2 power relay  2 frequency relay  1 Alarm relay  1 mA output * Net prices for 2015, ex works ProMinent Heidelberg ** or fixed cable sensors, if available !!With pH and ORP max. 10 m cable length!!  1 remote pause input  Wide range power supply 100 – 240 VAC  Sensor check for pH

9 Experts in Chem-Feed and Water Treatment Basic Package Free Chlorine with Compact Controller E. Basic package free chlorine with Compact Controller Basic free chlorine Packages Compact Controller free chlorine DCCa W 00 6 C0 0 01 0 EN) Bypass aramtur DGMa110T000 CLB 2-µA-5ppm (PN 1038902) ** Standard prices, result in net price for ≥ 10 units366 € each < 10 units403 € each panel mounting adaptor14 € each PN 1037273 Now Standard Prices !* always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output * Net prices for 2015, ex works ProMinent Heidelberg ** fixed cable cannot be extended!  1 remote pause input  Wide range power supply 100 – 240 VAC

10 Experts in Chem-Feed and Water Treatment Standard Package Free Chlorine with D1Cc Controller F. Standard package free chlorine with D1Cb, (membrane covered sensor) Standard free chlorine *Net prices for 2015 ex works ProMinent Heidelberg Bypass aramtur DGMa101T000 2-wire cable, 10m (PN 725122) CLB 1 mA-10ppm PN 1033879) Standard prices, result in net price for ≥ 10 units542 € each < 10 units582 € each The D1C controller has a general ID code. Measured variable and language has to be chosen during start-up: Advantage: The controller can be used for all measurements Now Standard Prices !* D1CBW00601000V0101 1G2200 always included:  2-way PID control  2 power relay  2 frequency relay  1 Alarm relay  1 mA output  1 remote pause input  Wide range power supply 100 – 240 VAC

11 Experts in Chem-Feed and Water Treatment Standard Package Free Chlorine with D1Cc Controller F1. Standard package free chlorine with D1Cc, (membrane covered sensor) Standard free chlorine *Net prices for 2015, ex works ProMinent Heidelberg Bypass aramtur DGMa101T000 2-wire cable, 10m (PN 725122) CLB 1 mA-10ppm PN 1033879) Standard prices, result in net price for ≥ 10 units579 € each < 10 units619 € each The D1C controller has a general ID code. Measured variable and language has to be chosen during start-up: Advantage: The controller can be used for all measurements Now Standard Prices !* D1CCD00601000V0101 1G2200 always included:  2-way PID control  2 power relay  2 frequency relay  1 Alarm relay  1 mA output  1 remote pause input  Wide range power supply 100 – 240 VAC

12 Experts in Chem-Feed and Water Treatment Standard Package Free Chlorine with D1Cc Controller F2. Standard package free chlorine with D1Cc, (membrane covered sensor Type CLR) Standard free chlorine *Net prices for 2015, ex works ProMinent Heidelberg Bypass aramtur DGMa101T000 2-wire cable, 10m (PN 725122) CLR1 mA-200 ppm special version) Standard prices, result in net price for ≥ 10 units682 € each < 10 units722 € each The D1C controller has a general ID code. Measured variable and language has to be chosen during start-up: Advantage: The controller can be used for all measurements Now Standard Prices !* D1CCD00601000V0101 1G2200 always included:  2-way PID control  2 power relay  2 frequency relay  1 Alarm relay  1 mA output  1 remote pause input  Wide range power supply 100 – 240 VAC

13 Experts in Chem-Feed and Water Treatment G. Basic package conductive conductivity with Compact Controller, COND_C and LFTK1DE Basic Conductivity Packages Cable, 4-pole, 10 m (PN 1046027) Conductivity Sensor LFT K1 DE (PN 1002822) Special Prices* *Net prices for 2015, ex works ProMinent Heidelberg Adaptor DN 20, PP, R 3/4" (PN 1001835) Basic Conductivity with Compact Controller Standard prices, result in net price for ≥ 10 units285 € each < 10 units325 € each panel mounting adaptor14 € each PN 1037273 always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output Compact Controller Conductivity COND_C (DCCa W 00 6 L3 0 01 0 EN)  1 remote pause input  Wide range power supply 100 – 240 VAC

14 Experts in Chem-Feed and Water Treatment G. Basic package conductive conductivity with Compact Controller, COND_C and LMP001 Basic Conductivity Packages Cable, 4-pole, 10 m (PN 1046027) Conductivity Sensor LMP001 (PN 1002822) Special Prices* *Net prices for 2015, works ProMinent Heidelberg Adaptor DN 25, PVC, R 3/4" (PN 356410 + 356923) Basic Conductivity with Compact Controller Compact Controller Conductivity COND_C (DCCa W 00 6 L3 0 01 0 EN) Standard prices, result in net price for ≥ 10 units339 € each < 10 units379 € each panel mounting adaptor14 € each PN 1037273 always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output  1 remote pause input  Wide range power supply 100 – 240 VAC

15 Experts in Chem-Feed and Water Treatment H. Basic package conductive conductivity with Compact Controller, COND_C and LFTK1DE Basic Conductivity Packages Cable, 4-pole, 10 m (PN 1046027) Conductivity Sensor LFT K1 DE (PN 1002822) Special Prices* *Net prices for 2015, ex works ProMinent Heidelberg Basic Conductivity with Compact Controller Standard prices, result in net price for ≥ 10 units362 € each < 10 units402 € each panel mounting adaptor14 € each PN 1037273 always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output Bypass aramtur DGMa110T000 Compact Controller Conductivity COND_C (DCCa W 00 6 L3 0 01 0 EN)  1 remote pause input  Wide range power supply 100 – 240 VAC

16 Experts in Chem-Feed and Water Treatment H1. Basic package conductive conductivity with Compact Controller, COND_C and LFTK1DE Basic Conductivity Packages Cable, 4-pole, 15 m (PN 1046027) Conductivity Sensor LFT K1 DE (PN 1002822) Special Prices* Net prices for 2015 ex works ProMinent Heidelberg Basic Conductivity with Compact Controller Standard prices, result in net price for ≥ 10 units385 € each < 10 units425 € each panel mounting adaptor14 € each PN 1037273 always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output  1 remote pause input  Wide range power supply Bypass aramtur DGMa110T000 Compact Controller Conductivity COND_C (DCCa W 00 6 L3 0 01 0 EN)  1 remote pause input  Wide range power supply 100 – 240 VAC

17 Experts in Chem-Feed and Water Treatment H2. Basic package inductive conductivity with Compact Controller, COND_I and ICT 1 sensor Basic Conductivity Packages Inductive sensor with 7m cable and PVC DN 40 union end #1023244 Special Prices* *Net prices for 2015, ex works ProMinent Heidelberg Basic inductive Conductivity with Compact Controller Standard prices, result in net price for ≥ 10 units399 € each < 10 units439 € each panel mounting adaptor14 € each PN 1037273 always included:  1-way PID control  1 power relay  1 frequency relay  1 mA output  1 remote pause input  Wide range power supply 100 – 240 VAC Compact Controller Conductivity COND_C (DCCa W 00 6 L6 0 01 0 EN)

18 Experts in Chem-Feed and Water Treatment Which sensor for which application? Please order the packages via d.berger@prominent.de, select the wanted sensor type:d.berger@prominent.de Select the sensor:  PHES 112 SE for clear water, e.g. applications like potable water, swimming pool water, max. 3 bar  PHEP 112 SE for clear water, e.g. applications like potable water, swimming pool water  RHER 112 SE for waste water with sludge and solids, e.g. applications like cooling tower, sewage water  PHEX 112 SE for waste water with a high sludge and solid concentration  Analogue for ORP sensors  The chlorine and conductive conductivity sensors are only suitable for clear water! The inductive principle is for the use in e.g. waste water