Introduction to PCB Congeners Presented by Jamie Fox
2
1 month old doxin chihuahua mix puppy, eats hard food and isn’t potty trained no worms or fleas rehomming fee of 75$ call or text needs home ASAP
3
Purpose To provide general information on PCB’s. To describe the analytical methods. To describe uncommon terms. Example Reports To answer your questions.
4
WHAT ARE PCB’S?
5
What are PCB’s? Aroclors are a mixture of PCB’s numbered by type and percent chlorine content (i.e. 1242 is 42% chlorine) PCB’s are a group of 209 polychlorinated biphenyl congeners. Commonly referred to by a numbering system. 12 PCB’s (WHO list) are distinguished as a sub-group. These are considered to be the most toxic. They are the ones whose toxicity is defined. Totals are reported by homolog group, e.g. Total Mono PCB’s, Totals Di PCB’s, etc. and Total PCB Congeners.
6
What are PCBs? Polychlorinated Biphenyl (10 substitution positions) 2 3 4 55’ 4’ 3’ 2’ Cl n 209 Mono-Deca PCB Congeners 6’6
7
What are PCBs? PCB-77 PCB-81 PCB-105 PCB-114 PCB-118 PCB-123 PCB-126 PCB-156 PCB-157 PCB-167 PCB-169 PCB-189 The Twelve Toxic Congeners
8
PCB EFFECTS
9
The PCB Problem Manufactured in US from 1929 to 70’s for transformers, capacitors, paints, caulk, etc. Ubiquitous and persistent in the environment Neuroendocrine disruptor, teratogen, likely carcinogen Contaminated sites everywhere—Great Lakes, Hudson River, Newtown Creek
10
METHODS
11
Aroclor Method Method 8082 is historically the most common analytical method for measuring PCB’s. GC/ECD Uses fingerprinting method Common RL is low ppb Least expensive
12
PCB Homolog Method Method 680 is commonly used in conjunction with pesticide analysis. GC/LRMS SIM Measures by homolog group Common RL is mid ppt
13
PCB Congener Method Method 1668 can be used for Clean Water Act (CWA) compliance (e.g., NPDES permits, TMDL studies, CBC). Versions A, B*, and C exist. Versions A and C are very similar and of primary concern. Existing studies use version A. Version C has tighter QA/QC limits, causing about 5- 20% more failures Common RL is low ppq * Version B was largely ignored by laboratory and regulators due to disagreements over QA/QC requirements, too loose in some areas, too tight in others.
14
METHOD 1668 USES
15
TMDL TMDL = Total Maximum Daily Load Section 303(d) of CWA Used to study impacted waterways Calculates allowable pollutant discharge limits that ensures water quality standards are met Example: Delaware River Delaware River Basin Commission Virginia DEQ
16
Individual Congeners Verify weathering of Aroclors Due to “fingerprint” nature of Method 8082, PCBs may still be present Weathering may result in Aroclor ND’s that would be detected as individual congeners Congener specific analysis has been used for source identification based on industrial process
17
Bioaccumulation Tissue analysis often requires low detection limits Human health concerns drive PCB regulatory limits lower than traditional analytical method RLs
18
ISOTOPE DILUTION
19
Isotope Dilution What do we do with the 13 C labeled congeners? (PCBs and Dioxins) Act as surrogates and internal standards for the native congeners at each step in the preparation and analysis: Extraction Standards (ES) just before the extraction. Cleanup Standards (CS) just before the fractionation. Injection Standards (JS) just before the injection.
20
Isotope Dilution Extraction Standards (ES) When? Extraction Standards are introduced inside the sample matrix before the extraction step. Why? Used to measure the overall extraction and fractionation efficiency Used in the qualitative and quantitative characterizations of native congeners
21
Isotope Dilution Cleanup Standards (CS) When? Cleanup Standards are introduced to the sample after extraction but prior to the cleanup step (when applicable.) Why? Used to measure the efficiency associated with the fractionation step alone.
22
Isotope Dilution Injection Standards (JS) When? Injection Standards are introduced to the sample after cleanup but prior to injection. Why? They act as internal standards to determine the recoveries of the Extraction and Cleanup Standards. Provide a measurement of injection efficiency useful to the analyst.
23
HIGH RESOLUTION MASS SPECTROMETRY
24
High Resolution Mass Spectrometry How high is high? Well, it’s 10000 Resolving Power! The ability to zoom in on a mass spectrum and tell the differences between masses that are very close in weight.
25
High Resolution Mass Spectrometry 5% line 100ppm
26
UNCOMMON TERMS
27
Sample specific Estimated Detection Limit (EDL) Not the same as a Method Detection Limit (MDL) The concentration of a given analyte required to produce a signal with a peak height of at least 2.5 times the background signal level. Used for blanks, not for samples as the method is written
28
Toxic Equivalency Quotient (TEQ) Simplest means of reporting a sample’s toxicity, one number! TEQ is a sum based on the concentration of the toxic PCB congeners and their relative toxicity to 2,3,7,8- TCDD. Important client decisions include: the choice of Toxic Equivalency Factors (TEFs) treatment of non-detects the use of EMPCs or not
29
Example PCB TEQ TEF WHO2005Adjusted ResultTEFResult PCB-77153x0.0001=0.0153 PCB-81x0.0003=0 PCB-105x0.00003=0 PCB-11436.2x0.00003=0.00109 PCB-118205x0.00003=0.00615 PCB-12389.0x0.00003=0.00267 PCB-12630x0.1=3.01 PCB-156/157431x0.00003=0.0129 PCB-167x0.00003=0 PCB-169105x0.03=3.15 PCB-189146x0.00003=0.00438 TEQ=6.20
30
REPORT EXAMPLES
31
Example 1668 Form
33