Download presentation
Presentation is loading. Please wait.
Published byMiles Preston Modified over 9 years ago
1
AMBIENT AIR QUALITY MONITORING NETWORK Item No. 3.0
2
National Air Quality Monitoring Programme (NAMP) N.A.M.P. started in 1984 with 7 stations in Agra and Anpara. Presently 424 operating stations in 175 cities/towns. Parameters being monitored SO 2, NO 2, RSPM (PM10), SPM at all stations. Trace Metals, PAHs, NH 3 in few cities; BTX, Ozone monitoring conducted in Delhi and some major cities NAMP – present scenario
3
Existing stations (sanctioned)-604 No. of States covered-28 No. of Union territories covered-06 No. of cities/towns covered-258 Operating stations- 424 No. of states covered-26 No. of Union territories covered-05 No. of cities/towns covered-175 Target on XIth five year plan-700 Target on XIIth five year plan-1000 Proposal Required for new stations (within next F.Y. 2010-2011 & 2011-2012) -150 Road Map to achieve target 2010-2012 604+150=754 2010-2011-604+75=679 2011-2012-679+75=754 NATIONAL AMBIENT AIR QUALITY MONITORING PROGRAMME (NAMP) NAMP NETWORK AT A GLANCE
4
NAMP Parameters Parameters monitored Criteria pollutants viz. PM10, SO2, NO2 monitored at all (424) locations Ammonia, CO, O 3, PM2.5 and Lead monitored at few locations; Following parameters needs to be monitored: PM 2.5 Benzo(a)pyrene Carbon monoxide Ozone Benzene Metals
5
Monitoring Programme for additional parameters of Ambient Air Quality for next two years ( 2010-2011 & 2011-2012) Sl. NoParameter Financial year Total Stations in two F.Y. 2010-2011 No. of Stations 20 11-2012 No. of Stations 1.Sulphur dioxide (SO 2 )75 150 2.Nitrogen dioxide (NO 2 )75 150 3.Particulate matter (PM 10 )75 150 4.Particulate matter(PM 2.5 )75 150 5.Ozone (O 3 )1011 21 6.Carbon monoxide (CO)1011 21 7.Ammonia (NH 3 )75 150 8. & 9. Lead & Nickel (Pb & Ni ) 75 150 10.Benzene (C 6 H 6 )1011 21 11.Benzo (a) Pyrene (BaP), particulate phase only 75 150
6
Capital and O&M Cost Financial Requirement for Strengthening the National Ambient Air Quality Network The fund requirement for additional parameters for two years: Rs. 4329.45 Lacs. The Financial Year wise break up is as below Financial Year 2010-2011 = Rs. 2139.5 Lacs Financial Year 2011-2012 = Rs. 2189.95 Lacs Operation and Maintenance cost for two years is Rs.2708.652 Lacs. The Financial Year break up is as below Financial Year 2010-2011 = Rs. 899.065 Lacs Financial Year 2011-2012 = Rs. 1809.587 Lacs
7
Continuous Ambient Air Quality Monitoring Stations for Non- Attainment Cities Based on Air Quality data, 72 cities are non attainment cities, where the prescribed National Ambient Air Quality Standards (NAAQS) are in exceedence; As per the directions of Hon’ble Supreme Court setting up of CAAQMS in 16 cities on 50:50 cost sharing basis Nine stations one each at Hyderabad, Mumbai, Pune, Solapur, Bangalore, Agra, Kanpur Varanasi & Ahmedabad are in operation. Existing Kolkata station of WBPCB is upgraded. CAAQMS at Jodhpur be commissioned by December 2010; Remaining stations at various stages of tendering; CPCB spent Rs. 600 Lacs for CAAQMS project in 16 cities on 50:50 cost sharing basis.
8
Continuous Ambient Air Quality Monitoring Station/Network. Private Participation in the Management of CAAQMS Model- I:Operation Contract - All 12 stations (Cities covered: Delhi, Lucknow, Bangalore & Chennai) All are connected to Central Management units at CPCB Head Office, Delhi (Expenditure incurred: 11.25 crore) Model-II: Build Own & Operate (BOO) Contract (Cities covered: Ahmedabad & Mumbai) Under implementation
9
Each station costs Rs. 110.00 Lacs; Of 72 Non Attainment cities, In 23 cities ongoing projects. Estimated Capital cost for remaining 49cities will be: 49X110 Lacs=Rs. 5390 Lacs; 12 SPCBs/PCCs proposed for Continuous Ambient Air Quality Monitoring Stations (CAAQMS) for 33 cities. The Capital cost for 33 CAAQMS installations will be Rs. 3630 Lacs. (on 50:50 cost sharing basis ) The annual Operation & Maintenance cost of each station will be borne by the respective SPCBs/PCCs The monitoring data of the CAAQMS will be available at SPCBs/ PCCs and CPCB website. Proposed expansion of CAAQMS in other Non Attainment Cities Estimated cost - CAAQMS
10
Issues on Ambient Air Quality Monitoring To achieve 700 stations as specified in XIth Five year plan, SPCBs to identify sites/parameters and the additional budget requirement ; In the next five years plan (12 th FY plan).; the SPCBs/ PCCs may specify the location and cost requirement on 50:50 sharing basis; Calibrations of equipments/instruments: Training of manpower following quality assurance/quality control guidelines, following standardized methods, locating stations as per guidelines; Number of online stations to be established at residential and industrial sites; Data and Payment Certificates gaps: The ambient air quality data as well as payment certificates must be sent timely; For CAAQMS installed and in operation in, a standardized data transfer/processing system required for free flow of information.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.