Ambient Air Quality Monitoring Methods Lydia Scheer ITEP
2
2 What will we learn? Reasons for monitoring ambient air quality Methods available for different pollutants and/or parameters Considerations for air monitoring National and regional issues related to air monitoring
3
3 Why Monitor Air Quality? Examine and characterize airshed Health or environmental effects Cultural reasons Political issues Economic or land-use planning Gauge compliance with standards/regulations NAAQS attainment or non-attainment EPA Green Book lists NA areas (www.epa.gov/airquality/greenbk/) www.epa.gov/airquality/greenbk/ Non-attainment: progress toward attainment What control/prevention strategies are needed? Are they working? Why is your tribe monitoring? Answering this question will help to determine your air monitoring objectives
4
4 Evaluating Impacts Think about monitoring objectives—why are you monitoring? Consider impacts at both the receptor and the source What is the level at source? What are downwind/upwind levels? What areas are most impacted and/or what areas are you concerned about? (receptors) Establish baseline data representative of your area Determine maximum, average pollutant concentrations Will you be issuing health alerts or monitoring trends? Are you meeting your objectives?
5
5 Network Considerations “Network” can be a single site or multiple sites Monitoring objectives Meteorology & pollutant/precursor transport Monitoring schedule Site requirements, access and security, long-term viability NAAQS monitoring: 40 CFR Part 58 Appendix E Met monitoring: EPA-454/R-99-005 Special projects often have their own specific requirements Necessary to review and modify network based on objectives and changes to surrounding conditions
6
6 Equipment Considerations Monitors/samplers & sensors FRM or FEM or not? Must be FRM/FEM in order to compare to NAAQS (40CFR Part 53) Collocation requirements for some types of monitoring Ancillary equipment Dataloggers QA/QC equipment incl. flow meters, transfer standards, calibrators, etc. Consumables Grease/oil Filters/filter tape Concrete pad and shelter Electricity requirements A/C or heating needs
7
Regulatory Considerations To officially compare to the NAAQS (for attainment designations or compliance) you MUST follow all requirements outlined in 40CFR Part 58 All EPA-funded projects involving data collection require approved QAPP 7
8
8 Pollutants & Parameters Criteria pollutants Particulates PM10 (particulate matter < 10 mm) PM2.5 (particulate matter < 2.5 mm) Ozone Lead SO2 NOx CO Air Toxics (HAPs) and/or VOCs Meteorological parameters Acid & Mercury deposition
9
Particle Sizes Human Hair (~70 µm diameter) PM 2.5 (2.5 µm) PM 10 ( 10µm ) Cross Section: (~70 µm)
10
10 PM Filter-Based Samplers HiVol (TSP or PM10 only), MiniVol, Partisol, others Most HiVols & Partisols are FRM or FEM (epa.gov/ttn) 24-hour sample collected onto filter Single channel or sequential option for Partisol Filter mass weighed by lab to determine average ambient concentration Samples can be analyzed further for constituents (speciation)
11
11 Filter-Based Pros & Cons Filter-based equipment demands more resources Personnel/time Filters & other consumables Laboratory analysis is costly Less expensive to purchase than continuous samplers Data are not “real-time” MiniVols are more portable than larger equipment MiniVol is not FRM or FEM MiniVol can sample PM10 or PM2.5 MiniVol data is not legally-defensible
12
12 R&P PM2.5 Partisol FRM
13
13 HiVol & MiniVol
14
14 Credit: www.rpco.com
15
15 Filters 47mm Teflon-coated Glass (PM2.5 or PM10) 47mm Quartz Fiber or pure Teflon (used for speciation) 8” x 10” Glass Fiber (PM10 HiVol) Also specialized filters for some models See examples
16
16 Continuous PM Monitors Examples: TEOM, BAM, Nephelometer (some applications) Collect samples “continuously” (readouts vary from every 5 minutes to every 1 hour) Particles collected on filter tape or pad and weight (mass) is analyzed internally Can be used for PM 10 or PM 2.5 Several models are FEM
17
17 TEOM & BAM
18
18 Continuous Pros & Cons Provides data in “real-time” Continuous equipment is more costly/fragile Automated readings and no filters means minimized personnel time & lab costs Some consumables and maintenance Needs constantly reliable power source & adequate shelter Requires Datalogger/DAS
19
19 Dataloggers/DAS Electric or electronic computing devices that record measurements from other instruments Various programming requirements and configurations Datalogger input connection must match sensor output connection Helpful to understand basic electricity concepts for troubleshooting
20
Datalogger Characteristics Analog Transmits voltage reading, translated into pollutant concentration or other parameter Typically linear relationship between outputs and readings enables logging values anywhere within the range “Noise” in analog connections can introduce error Digital Transmits specific values for pollutant concentration or other parameters Values can increase or decrease only at specific, discrete intervals and not between intervals 20
21
21 Gaseous Monitoring Methods “Passive” sampling Often a chemical reaction involved, end sample is analyzed Spectrophotometry and UV Photometry Measures amount of light a sample absorbs Primarily used for SO2 & Ozone Chemiluminescence Chemical reactions gives off light of a certain color Used for O3, NOx, SOx and H2S
22
22 Sampling Equipment- Gaseous Pollutants
23
23 Air Toxics/HAPs 187 Hazardous Air Pollutants (HAPs) Volatile & semi-volatile organic vapors e.g., benzene, dioxin, formaldehyde, etc. Heavy-metal dust, aerosols & vapors e.g., mercury, nickel, antimony, etc. Inorganic & mineral dust, aerosols & vapors e.g., arsenic, asbestos, etc. Radionuclides Including radon
24
Sampling Methods - HAPs Multiple methods depending on pollutant and emission process Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air (Method TO-1, etc.) Compendium of Methods for the Determination of Inorganic Compounds in Ambient Air (Method IO-1, etc.) 24 Photo courtesy of Frank BlackCloud, Spirit Lake Tribe
25
25 Meteorological Monitoring Can be conducted along with ambient air monitoring Helps to identify where pollution is coming from and/or where its impacts are greatest Some ambient air samplers & dataloggers can record limited met data Meteorological parameters to consider Wind speed (how far?) Wind direction (where/what direction?) Temperature (affects aerosolization of particles) Barometric pressure (impacts atmospheric conditions affecting transport) Relative humidity (affects aerosolization of particles) Solar radiation (affects formation of ozone)
26
26 TOWERS WIND SENSORS
27
27 Atmospheric Deposition Wet Deposition (“Acid Rain”) Monitored by National Atmospheric Deposition Program (NADP) Acid deposition occurs when pollutants (primarily SOx or NOx) react in atmosphere with water vapor & returns to earth as precipitation (rain, snow, fog) Measurements are made for pH and conductivity and precipitation Dry Deposition Monitored by the Clean Air Status & Trends Network (CASTNET) Occurs when pollutants react, but not with water Pollutants settle out of atmosphere as particles or gases
28
28 Mercury Deposition Mercury Deposition Network part of NADP analyzes mercury samples from wet deposition monitoring Monitoring for elemental and inorganic mercury conducted at the source Organic mercury (methylmercury) samples can also be collected from environmental receptors Aquatic and other wildlife Wetlands/waterways Sediments
29
29 Typical NADP Site
30
30 What We Just Covered Ambient air pollution can be monitored, sampled and/or analyzed in numerous ways Sampling types include filter-based, continuous, passive and chemical-based methods All monitoring methods have pros and cons Monitoring may or may not be important to meet certain needs of an air program EPA regularly revises NAAQS standards