Rehabilitation and maintenance of buildings - 02 Karel Mikeš
2
2 Contents Properties of material Failures of steel structures Types of refurbishment Methods of reliability verification Basis of member design of steel structures Basis of joint design Assessment of steel structures Strengthening of members Strengthening and refurbishment of structures Refurbishment of masonry structures using steelwork Seismic upgrading using steel structure
3
3 Methods of reliability verification Design based on experience Empirical attitude Allowable stress method One safety factor Reduction of strength Actions not affected Method of limit states Real probabilistic methods Method of partial safety factors Semi-probabilistic method
4
4 Method of partial safety factors Partial safety factors: material factors M load factors F Ultimate Limit States... M ≥ 1, F > 1 Serviceability limit states... M = 1, F = 1 Basis of Eurocodes
5
5 Partial safety factors Characteristic values Partial factors M, F Reduction factors Design values Partial factors cover: Disadvantageous deviations from characteristic values Inaccuracy of action model Inaccuracy of structural model for analysis Inaccuracy of transformation factors
6
6 Eurocodes Design codes (Eurocodes) European codes from1980 European Comittee for Standartization (CEN) from 1990 CR - member from 1998 Preliminary codes (ENV) European codes (EN) ENV - National application document (NAD) – national specials EN - National annex, limited clauses Since 3/2010 should be valid in all CEN countries
7
7 Eurocodes – EN EN 1990 Eurocode 0 Basis of Structural Design EN 1991 Eurocode 1 Actions on structures EN 1992 Eurocode 2 Design of concrete structures EN 1993 Eurocode 3 Design of steel structures EN 1994 Eurocode 4 Design of composite steel and concrete structures EN 1995 Eurocode 5 Design of timber structures EN 1996 Eurocode 6 Design of masonry structures EN 1997 Eurocode 7 Geotechnical design EN 1998 Eurocode 8 Design of structures for earthquake resistance EN 1999 Eurocode 9 Design of aluminium structures
8
8 Eurocodes – EN Partial safety factors M = 1,00 (for steel) M2 = 1,25 LoadingEffectService load (SLS) Extreme load (ULS) Deadfavourable G = 1,0 G,min = 1,0 unfavourable G = 1,0 G,max = 1,35 Variable Q = 1,0 Q = 1,50
9
9 Contents Properties of material Failures of steel structures Types of refurbishment Methods of reliability verification Basis of design of steel structures Assessment of steel structures Strengthening of members Strengthening and refurbishment of structures Refurbishment of masonry structures using steelwork Seismic upgrading using steel structure
10
10 Basis of design of steel structures Eurocode EN 1993 Design of steel structures Method of partial safety factors Utilization of bi-linear stress-strain relation of steel Axial tension Axial compression Bending Shear Combination
11
11 Axial tension Stress distribution: (direct stress)
12
12 Axial tension Resistance: full cross-section (plastic resistance) N pl.Rd = A f y / M0 net cross-section at holes for fasteners N u.Rd = 0,9 A net f u / M2
13
13 Axial compression Design buckling resistance Buckling factor : covers the effect of buckling ( depends on cross-section type)
14
14 Axial compression Buckling Stability collapse buckling before f y is reached along cross-section Most frequent reason for collapse of S.S. Perfect (ideal) member- stability problem Real member - buckling resistance
15
15 Axial compression Stability of perfect member Straight member Pinned ends Centric loading Solution Euler –1744
16
16 Axial compression Critical (Euler’s) Force Critical Stress Slenderness
17
17 Axial compression Buckling of Member flexural or torsional Double axis symmetric profiles Slenderness y, z, zw flexural or flexural-torsional Uniaxial symmetric profiles Slenderness y, yzw flexural-torsional Non-symmetrical profiles Slenderness yzw It is taken into account in simplified form
18
18 Axial compression Buckling (effective) length Using Euler‘s formula for general bar Buckling length: Length of basic member (pinned ends, constant compression force) of the same cross-section with equal critical force as examined member L cr = L
19
19 Axial compression Buckling length Example - Cantilever Euler Cantilever L cr = 2 L =2
20
20 Axial compression Buckling resistance of real member Imperfections Geometric imperfections Initial curvature of the member axis, excentricity of the loading position Deviation from the theoretical shape of the cross-section Material imperfections Residual stresses Due to the welding, straightening or cooling Structural imperfections Imperfect function of hinges or fixed connections
21
21 Axial compression Results of experiments of compression members
22
22 Axial compression Buckling factor … imperfection factor depends on type of cross-section
23
23 Axial compression Buckling factor
24
24 Global analysis of structure Statically determinate structures Statically indeterminate structures Elastic analysis Plastic analysis Plastification of the part of the structure Idealised stress-strain relation
25
25 Global analysis of structure Elastic analysis Material satisfies Hooke’s law = E For steel under the yield point f y Ideal stress-strain diagram
26
26 Global analysis of structure Plastic analysis Two steps: Plastic check of governing cross-section Plastic global analysis At redundant structures Development of plastic mechanism
27
27 Global analysis of structure Step by step plastification of I cross section Development of plastic mechanism Sufficient rotation capacity of cross section
28
28 Global analysis of structure Utilization of cross section
29
29 Global analysis Utilization of cross section Elasto-elastic Distribution of internal forces based on elastic analysis Utilization of structural cross section elastic Elasto-plastic Distribution of internal forces based on elastic analysis Maximally loaded cross section utilized plastically Plasto-plastic Distribution of internal forces based on plastic analysis At plastic joints is cross section plastified
30
30 Classification of cross section class 1: Plastic hinges Plastic redistribution of inner forces Plasto-plastic analysis class 2: Fully plastified Limited rotation capacity Elasto-plastic analysis class 3: It is possible to reach the yield point at edge fibres Elasto-elastic analysis class 4: slender, at compression stresses buckle earlier before the yield is reached Elasto-elastic analysis
31
31 Classification of cross section Definition of cross-section class Classification for all parts with compression stress For every compressed part according to b/t ratio b... width of sheet t... thickness of sheet Maximum class ( cr,min ) governs
32
32
33
33 Classification of cross section Cross section of class 4 Plate buckling Ideal cross-section Replacement of real width with effective widths
34
34 Bending, shear Bending resistance M Rd Shear resistance V Rd
35
35 Bending, shear Design bending resistance Influence of cross-section class 1., 2. class 3. class 4. class f yd = f y / M0
36
36 Bending, shear Design shear resistance A v … shear area Small shear: V Ed 0,5 V pl,Rd combination M+V is neglected Large shear V Ed > 0,5 V pl,Rd combination M+V is considered
37
37 Bending, shear M+V - Large shear Reduction of strength on shear area: for symmetrical cross-section along y-y :
38
38 Bending Lateral-torsional buckling
39
39 Relative slenderness Bending Resistance with lateral-torsional buckling for cross section of class 1 a 2 for cross section of class 3 for cross section of class 4
40
40 Bending Beams not subjected to lat.-torsional buckling Lateral restraint of compression flange Beam bended in the direction of smaller rigidity Torsional rigidity of beam is high (closed cross section)
41
41 Serviceability limit states check relevant especially for beams Deflections Vibrations Reversible behaviour is required Elastic behaviour
42
42 Serviceability limit states Deflections Bending stiffness: E I max... resultant deflection 2... deflection due to variable load 0... chamber of beam 1... deflection due to dead load
43
43 Serviceability limit states Recommended limit deflections Limits should be agreed Just recommendations in National annexes Refurbishment – proper judgement of designer Limits according to ENV: Loadingfloorsroofs totalL/250L/200 variableL/300 (L/350)L/250