2 The grid as we know it was originally designed with 2 applications in mind:
The electric motor & The light bulb

3 The power delivered by the grid is not sufficiently reliable and clean for the
Digital World of today.

4 Power Disturbances, Cause & Effect
Causes Breakdown Nature and weather Interference by Human Effects Lost Revenue Lost Productivity Equipment damage Safety Frequency Noise Variation Harmonics Outages Sags / Brown out Sags Spikes Swells

5 End-to-end power solutions for the building, box and board
GE Critical Power Power Switching Uninterruptible Power Supplies DC Power Systems Embedded Power Automatic Transfer Switches Surge Protective Devices Paralleling Switchgear Three Phase UPS, kVA Single Phase UPS, 1-10kVA Global Services 48Vdc Power Plant Systems, 3,000-20,000A Line Power Panels DC Distribution, BDFBs AC-DC Rectifiers & Power Supplies DC-DC Isolated Converters DC-DC Point of Load (POLs) End-to-end power solutions for the building, box and board

6 Enhancing System Reliability for the World’s Most Critical Processes

7 Facility Locations relevant to MEA Region
ATS/PSG COE Chicago, USA UPS COE Riazzino, Switzerland Page 7

8 Products

9 Uninterruptible Power Supplies — UPS
VCL series Line interactive VCO series Double conversion GT series Double conversion LP series Double conversion Applications: desktop PC’s, cash registers, fax machine, ISDN/ADSLA adapters, etc. VA Applications: Desktop PC’s, workstations, small servers, switchboards, routers, switches, etc 1 – 2 – 3 kVA Cost effective Applications: Small/medium servers, dense power rack applications, security systems 6 and 10kVA Flexible in use (tower/rack) Applications: Networks, computer rooms, cable networks, security systems, medium office, call center etc. 3–5–6–8–10–15-20 kVA Critical applications

10 with inverter transformer
Uninterruptible Power Supplies — UPS LP series transformerless SG PurePulse series with inverter transformer TLE series Transformerless Applications: Computer rooms, small datacenters, security systems, networks. 10, 20, 30, 40, 60, 80, 100, 120 kVA Smal footprint Input power factor correction Graphic display Static and manual bypass Cost effective Applications: Industrial, telecom, manufacturing processes, complete site protection, medical applications 10, 20, 30, 40, 60, 80, 100, 120, 160, 200, 250, 300, 400, 500, 600 kVA Very low input current harmonic distortion (THDI <2%) High output power factor 0.9 leading and lagging High efficiency Long backup time Graphic display Applications: Datacenters, call centers, IT infrostructure 160, 200, 320, 400, 600, 800 kW Very low input current harmonic distortion (THDI <2%) Output power factor 1 Very High efficiency Full colour Graphic display

11 Zenith Automatic Transfer Switches -ATS
GTX Series ZTX Series ZTG Series ZTS Series ZTE Series Applications: Small Frame Commercial and Light Industrial Standard Transition Amp, 380/416 Volt ratings Applications: Small Frame Commercial and Light Industrial Standard Transition Amp, Volt ratings Applications: General purpose Commercial and Industrial Standard & Delayed Transition Amp & Volt ratings Applications: Business Critical Applications Standard, Delayed, Closed Transition Bypass versions available with all Transition modes Amp ratings Volt ratings Applications: Life Safety & Mission Critical Applications PQ metering, Enhanced Diagnostics & Connectivity, Standard, Delayed, Closed Transition & Bypass Amp, Volt ratings

12 Technology Highlights

13 Increasing focus on Cost of Ownership Increasing power density (W/sqm) Increasing criticality
High efficiency Driving need for smaller, more reliable and more efficient Power Quality equipment

14 Best in Class efficiency @50%, p.f.=1
Trends: Increase Efficiency Agenda Powerware 9395 275 kVA MGE 7000 160 kVA Chloride 80 NET 300 kVA GE SG PP S3 160 kVA GE SG PP S3 300 kVA GE TLE 200 kW GE TLE 400 kW 93.8 93.0 94.2 94.2 94.2 96.2 96.5 Best in Class p.f.=1

15 Trends: Increase Power Density
Agenda Powerware 9395 275 kVA MGE 7000 160 kVA Chloride 80 NET 300 kVA GE SG PP S3 160 kVA GE SG PP S3 300 kVA GE TLE 200 kW GE TLE 400 kW 0.43 0.75 0.48 0.48 0.37 0.35 0.31 footprint (m2)/100kW

16 SG CE PurePulse® rectifier – Efficiency
Trends: Increase Power Density Trends: Further Increase Efficiency Efficiency: Space Vector Modulation technology NEW: eBoost SG CE PurePulse® rectifier – Efficiency 0% 20% 40% 60% 80% 92% 100% 10% 25% 50% 75% Load Efficiency % Typical Operation High efficiency at any load Energy cost saving Air conditioning cost saving

17 Reliability: from single UPS to dual redundant systems
UPS: Uninterruptible Power Supply ISM: Intelligent Synchronization Module STS: Static Transfer Switch Battery-B Battery-A ISM UPS-B Input mains UPS-A Input mains STS-B STS-A Load-B Load-A

18 We ensure safe and reliable power.
g GE Critical Power We ensure safe and reliable power.