Download presentation
Presentation is loading. Please wait.
Published byBaldwin Jenkins Modified over 9 years ago
1
ME 102A Spring 2010 May 4, 2010 Jennifer Lew Stephen Tu
2
Fans cool a computer Rotational Speed Cooling Capacity CPU would almost instantly melt CPU: http://hardforum.com/showthread.php?t=1423185http://hardforum.com/showthread.php?t=1423185 Fan Grid: http://forums.legitreviews.com/about12716.htmlhttp://forums.legitreviews.com/about12716.html
3
Idea: Use fan blades as an Optical Encoder By measuring the number of pulses in a fixed period of time, can determine speed of blades Rotary: http://hades.mech.northwestern.edu/index.php/Rotary_Encoderhttp://hades.mech.northwestern.edu/index.php/Rotary_Encoder Fan: http://computershopper.com/shoptalk/components/silverstone-fm83-cram-more-fan-into-the-same-spacehttp://computershopper.com/shoptalk/components/silverstone-fm83-cram-more-fan-into-the-same-space
4
1. Fan Voltage Supplied Current Supplied Impellers 2. Sensors Infrared LED Phototransistor Circuit: Resistors, Voltage Supplied 3. LabVIEW VI Input number of impellers Implements GenerateCalibrationCurve() Displays RPM, voltage supplied to fan 4. Error Analysis Sensor is noisy, so must take many samples and consider confidence intervals Procedure for calibrating fan IR LED: http://www.solarbotics.com/assets/images/ir-led/ir-led_pl.jpghttp://www.solarbotics.com/assets/images/ir-led/ir-led_pl.jpg Phototransistor: http://farm3.static.flickr.com/2325/2105641666_1487ce594e.jpghttp://farm3.static.flickr.com/2325/2105641666_1487ce594e.jpg
5
Measurement Power Breadboard
7
Measured range Nominal RPM 95% Confidence Interval
8
IssueSolutionDrawback Current limit on power supply Use analog lab equipment that does not impose as stringent current limits. Makes the UI less robust, due to less automation Fluctuations in ambient light Limit RPM readings to phototransistor voltages of magnitude greater than 1.5 mV. Below 1.5mV-> RPM=0 The threshold voltage is not appropriate for all conditions Precision errorAllow user to specify number of iterations before displaying the mean value of iterations Increases accuracy but increases processing time