Download presentation
1
A FOUNDATION FIELDBUS System
2
SYSTEM302 - Linking Devices
4-20 mA Discrete I/O
3
WHAT IS A Linking Device?
Linking Devices WHAT IS A Linking Device?
4
A Linking Device Connects: Fieldbus High Speed Ethernet
LINKING DEVICES A Linking Device Connects: Fieldbus High Speed Ethernet H1 Foundation Fieldbus Networks Configured by Any FF Configuration Tool Linking Device FIELDBUS H1
5
LINKING DEVICES MAIN FEATURES
6
Organizes the communication, Passing the token.
LAS Organizes the communication, Passing the token. Fieldbus Ethernet
7
FF BRIDGES BETWEEN FIELDBUS NETWORKS
HSE Linking Device FIELDBUS H1 FIELDBUS H1 DEVICES ON DIFFERENT NETWORKS
8
DFI302 “DFI302” “SYSTEM302’s Linking Device !”
9
DFI302 “DFI302” “Much More Than Linking Device !”
10
Distribution and Scalability
Unique Distributed Modular Design Several Parallel Processors working together, as ONE!! Unlimited Expandability: Unlimited I/O Unlimited Control Capability Extreme Control Performance
11
Each DFI302 PROCESSOR Handles:
DFI302 PROCESSORS Each DFI302 PROCESSOR Handles: 256 Conventional Points (512 Points with I/O Coprocessor) 4 FF H1 Networks (Up to 64 Foundation Fieldbus Field Devices) 4 LAS 1 FF HSE Port 1 Modbus Gateway Network (As-i Bus, DeviceNet, Profibus to come) 100 Fieldbus Foundation Function Blocks
12
DISTRIBUTED ARCHITECTURE
Truly Distributed with Horizontal Comunication FIELDBUS H1 FIELDBUS H1 FIELDBUS H1
13
H1 in a Box- A DFI302 for 4 H1 Networks
Fully integrated - HSE + 4 FF H1 + Modbus DF52 and DF53 modules Power Supply and Impedance for 4 FF H1 ports DF51 module HSE 1 Modbus port 4 FF H1ports DF50 module Power Supply for DF51 + I/O modules
14
Dynamically Instantiable Function Blocks
15
Available Blocks in DFI302
RESOURCE DESCRIPTION RS RESOURCE TRANSDUCER BLOCKS DESCRIPTION DIAG Diagnostics Transducer HC Hardware Configuration Transducer MBCF Modbus Configuration TRD Transducer INPUT TRANSDUCER BLOCKS DESCRIPTION TEMP Temperature Transducer INPUT FUNCTION BLOCKS DESCRIPTION AI Analog Input DI Discrete Input MAI Multiple Analog Input MDI Multiple Discrete Input PUL Pulse Input
16
Available Blocks in DFI302
CONTROL AND CALCULATION FUNCTION BLOCKS DESCRIPTION PID PID Control EPID ENHANCED PID – It has all the standard features plus : bumpless or hard transfer from a “manual” mode to an “automatic” mode and bias. APID ADVANCED PID – It has all the standard features plus: bumpless or hard transfer from a “manual” mode to an “automatic” mode, bias. Adaptive gain, PI sampling, deadband for error, special treatment for error, ISA or parallel algorithm,.. ARTH Arithmetic - 9 predefined equation types SPLT Splitter - split ranging and sequencing. CHAR Signal Characterizer - 20 points curve INTG Integrator AALM Analog Alarm ISEL Input Selector - 4 inputs SPG Setpoint Ramp Generator TIME Timer
17
Available Blocks in DFI302
CONTROL AND CALCULATION FUNCTION BLOCKS DESCRIPTION LLAG Lead Lag DENS Density CT Constant FFET FLIP-FLOP and EDGE TRIGGER MBCS Modbus Control Slave MBSS Modbus Supervision Slave MBCM Modbus Control Master MBCS Modbus Control Slave AEQU Advanced Equations OUTPUT FUNCTION BLOCKS DESCRIPTION AO Analog Output DO Discrete Output MAO Multiple Analog Output MDO Multiple Discrete Output STEP Step Output PID
18
Homogenous Environment
Standard programming language The last language you need to learn Same everywhere Easy Full use of FF Status: bumpless, shutdown, Execution synchronization
19
SIMILAR TO DCS/PLC, But the signals are now Fieldbus.
DFI302 DIRECT I/O ACCESS DIGITAL I/O ANALOG I/O SIMILAR TO DCS/PLC, But the signals are now Fieldbus. HSE DFI302 Modbus FIELDBUS H1 DI DO Pulse 4-20 ma Profibus DP Modbus Other Protocols
20
I/O Modules List
21
I/O Modules List
22
I/O Modules List
23
I/O Modules List
24
DFI302 as a MODBUS GATEWAY DFI302 as Modbus Slave DFI302 DFI302
Ethernet DFI302 Proprietary Control Network Fieldbus H1 Legacy system with Modbus card Modbus DFI302 Modbus DFI302 as Modbus Master
25
MODBUS TPC/IP - Master/Slave
MODBUS TCP/IP DFI302 LC700 + ENET700 FIELDBUS H1 FIELDBUS H1
26
System Architecture
27
System Architecture
28
Power Supply Subsystem Modules List
29
DF52 Fieldbus Power Supply
Supply 24VDC for the Field Devices Operates with 90VAC through 220VAC Supplies power up to 64 field devices. DFI302 Integrated Design. Fail Led and Output Circuit. Short-Circuit Protection DIN-rail or panel mount
30
DF49(DF53) - 2(4) Channel Fieldbus Power Supply Impedance
Allows use of standard power supplies. 18 +/-2 V, 300 mA output. Built-in terminator DIN-rail or panel mount Active Impedance, allows redundancy DFI302 Integrated Design. Fail indication Short-Circuit Protection
31
DF49/53 Terminator Switches
+ IN - + OUT1 - + OUT2 - + OUT3 - ON + OUT4 - BT
32
DF47 Fieldbus Safety Barrier
Limits power to the classified area. Typically 8 hazardous area devices per barrier. Works as a repeater (Does not need a separate repeater). Uses a independent and isolated power supply.
33
DF47 Fieldbus Safety Barrier
PS Hazardous Area STILL 16 DEVICES PER CHANNEL
34
Extends the network up to 9,500 mts. Up to 4 repeaters per network.
DF48 Fieldbus Repeater Extends the network up to 9,500 mts. Up to 4 repeaters per network. PS
35
DFI302 Redundancy Redundant LAS Redundant Interface
Two paths to the field Redundant LAS Redundant Interface Processor Redundancy Available in January 2002
36
Choices are everything!
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.