© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 1 Contichrom ® animation - the CaptureSMB ® process principle -
2
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 2 Contichrom ® & CaptureSMB ® explained
3
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 3 Contichrom ® & CaptureSMB ® explained
4
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 4 Contichrom ® & CaptureSMB ® explained Feed column length Internal concentration t1t1 t2t2 t3t3 Feed Wasted resin capacity in batch chromatography
5
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 5 Feed Contichrom ® & CaptureSMB ® explained Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
6
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 6 Feed Contichrom ® & CaptureSMB ® explained Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
7
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 7 Wash Contichrom ® & CaptureSMB ® explained Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
8
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 8 Elution Contichrom ® & CaptureSMB ® explained Feed Product Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
9
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 9 Contichrom ® & CaptureSMB ® explained Feed CIP & Re-equilibration Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
10
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 10 Contichrom ® & CaptureSMB ® explained Feed Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
11
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 11 Contichrom ® & CaptureSMB ® explained Wash Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
12
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 12 Contichrom ® & CaptureSMB ® explained Elution Product Feed Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
13
© ChromaCon AG // www.chromacon.ch // the CaptureSMB ® process principle 13 Contichrom ® & CaptureSMB ® explained CIP & Re-equil. Feed Start over Step 1: Feed & wash Step 2: elute product feed column Step 3: CIP & re-equil. feed column
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.