Presentation is loading. Please wait.

Presentation is loading. Please wait.

Portion of the OSSF Rules regulating the minimum distance of OSSF components from various features.

Similar presentations


Presentation on theme: "Portion of the OSSF Rules regulating the minimum distance of OSSF components from various features."— Presentation transcript:

1

2 Portion of the OSSF Rules regulating the minimum distance of OSSF components from various features

3

4

5

6 Distance To:  Tanks, 50 ft  Sewer Pipe with Watertight Joints, 50 ft  Edge of effluent spray area or effluent disposal area, 150 ft

7 Distance to any OSSF component, 10 ft

8 Distance to an effluent disposal area is 100 ft

9 If a well is completed in accordance to 16 TAC chapter 76.1000(a)(1) it may be 50 ft from a disposal area This chapter addresses grouting of a well

10

11

12 The Water Information Integration & Dissemination System (WIID) http://wiid.twdb.state.tx.us/Index.asp For the most recent well reports

13

14 The TCEQ Water Well Report Viewer http://gis3.tceq.state.tx.us/waterwell public/index.jsp Older reports

15

16  25 ft in a clay soil, i.e. soil absorption rate (Ra) < 0.1 gal/sf/day,  75 ft in a soil predominantly sand, i.e. Ra > 0.1; Or may be 50 ft with secondary (aerobic) treatment and disinfection

17 In the latter case, to place a drip disposal area 50 ft from a body of water in a predominantly sandy soil, aerobic treatment and disinfection is required  Continuous chlorination is not recommended by some manufacturers  UV disinfection is an alternative

18

19

20  All components of an OSSF must be 1 ft from the easement, unless permission is granted by the easement holder  Easements are recorded with the County Clerk’s office. Other sources are recorded plats & some surveys

21  Distance to tanks, drip system disposal area, soil absorption systems is 1 ft  A surface application spray area may spray to the edge of the easement

22 Is there an underground easement on this site?  County clerk’s office has recorded easement or easement abandonment documents  “Call before you dig” & other utility location services  Fence line markers  Survey  Subdivision plat  Title Search

23  Distance to tanks is 5 ft  Distance to sewer pipe is 10 ft  Distance to surface application area,10 ft  Distance to drip disposal area is 10 ft when Ra 0.1

24  No minimum distance to the edge of a surface application (spray) area  No minimum distance to a drip irrigation disposal area  Tanks and sewer pipes with untreated sewage must be 5 ft away

25

26 THE END