Download presentation
Presentation is loading. Please wait.
Published byJosephine Pitts Modified over 9 years ago
1
Northwestern University Rod Ruoff Nanotechnology Fracture Mechanics of One- Dimensional Nanostructures
2
Northwestern University Rod Ruoff Nanotechnology Carbon Nanotube Source SEM image of powdered cathode deposit core material with 30-40% MWCNT content from MER Corp. SEM image of separated MWCNTs on a silicon wafer, after fractionation. Arc-grown Multi-wall Carbon Nanotubes (MWCNTs) from MER Corp. AZ. were studied in this work. A simple fractionation process was used to remove some impurities and increase nanotube concentration.
3
Northwestern University Rod Ruoff Nanotechnology Testing Tool: Nanomanipulator A home-built nanomanipulator is used to perform mechanics study inside vacuum chamber of an scanning electron microscope (SEM). X-Y stage Piezo bimorph Z stage Cantilever Holder Specimen/ Cantilever Holder X-Y Stage Z-stage Piezoelectric Actuator Nanomanipulator inside vacuum chamber of FEI Nova 600 SEM (Ruoff group) Home-built nano-manipulator
4
Northwestern University Rod Ruoff Nanotechnology Nanoscale Tensile Test Experimental Setup X-Y Stage rigid cantilever soft cantilever Z Stage Tensile Test Schematic L L+ s Atomic force microscope (AFM) cantilevers are used as manipulation tools and force-sensing elements. MWCNT
5
Northwestern University Rod Ruoff Nanotechnology In situ Clamping - EBID Electron beam induced deposition (EBID) is the process of using a high- intensity electron beam to deposit structures on a scanned surface. EBID is commonly used to make clamps in situ inside SEM. A CNT in contact with an AFM tip, before and after EBID clamping EBID principle Hydrocarbon molecules EBID clamp Exposure area
6
Northwestern University Rod Ruoff Nanotechnology “Sword-in-sheath” Fracture Outer shell Inner shells Cross-sectional area: D : inter-layer separation of graphite, 0.34 nm Multi-wall carbon nanotubes fracture in a “sword-in sheath” manner during tensile test.
7
Northwestern University Rod Ruoff Nanotechnology MWCNT Diameter Measurement (a) AFM chip holder model AFM cantilevers (c) Gatan TEM straining holder (model 654) (d) SEM and TEM images of a MWCNT fragment attached to an AFM tip. (b) An AFM chip in the AFM chip holder Cantilever holders were designed to hold a shortened AFM chip for nanotube diameter measurement in TEM.
8
Northwestern University Rod Ruoff Nanotechnology Stress & Strain Measurements The whole tensile testing process was recorded by taking SEM images at each loading step.
9
Northwestern University Rod Ruoff Nanotechnology MWCNT Tensile Testing Result Fracture Strength Elastic Modulus Average elastic modulus: ~ 910 GPa
10
Northwestern University Rod Ruoff Nanotechnology Multiple Loading (Tube #6) Test # Gauge Length ( m) Breaking Force (nN) Tensile Strength (GPa) Failure Strain (%) Elastic Modulus (GPa) 14.08220 21 1.41.8 0.31200 210 23.75240 23 1.41.9 0.31250 210 33.46420 41 2.63.0 0.21230 130 (1)(2)(3)
11
Northwestern University Rod Ruoff Nanotechnology Nanoparticle Chain Aggregates Breaking Force: 42 25 nN Tensile Strength: 40 -100 MPa Elastic Modulus : 200 - 600 MPa Particle Contact Force: 8 4 nN Tensile Testing Stretching a chain Contact Force Measurement Carbon nanoparticle chain aggregates Nanoparticle diameter: 25-35 nm Chain length: ~ 2 m
12
Northwestern University Rod Ruoff Nanotechnology Nonlinearity: Large Deflection + Misalignment where F x =F sin and F y =F cos (Transformation; Converting to elliptic integrals) F(k),F( ,k) complete and incomplete elliptic integral of first kind. k and 1 are obtained from angle 0 with following relationships: L F x y yy 00 xx s FyFy FxFx (x,y)
13
Northwestern University Rod Ruoff Nanotechnology Experimental Data Analysis Slope 0 (degree) Loading Angle (degree) Applied Load Vertical Deflection y Linear ( N) Analytical ( N) Error (%) Measured ( m) Linear ( m) Analytical ( m) 11.036.825.329.714.842.942.242.3 17.45.523.524.95.668.770.870.3 9.2242.020.823.913.030.632.232.3 11.62.019.419.61.041.440.540.4 15.024.327.631.412.152.952.452.3 AFM cantilevers were used as force-sensing elements in our nanoscale tensile testing experiments on templated carbon nanotubes inside SEM. Large deflection of the cantilever beam was encountered in the tests along with non-ideal alignment of the specimens. The linear analysis underestimated the applied load up to 15 %.
14
Northwestern University Rod Ruoff Nanotechnology Error in Linear Estimation Normalization Linear analysis Analytical analysis