Download presentation
1
Calibration Measurement Requirement Summary
Modernization and Calibration Measurement Requirement Summary CMRS Greg Hogan NSWC Corona Det Seal Beach
2
Life Cycle Stages Technical Measurement Requirement
Developed from Prime System requirements Contracting/Active Procurement Working with Industry to get best value Warranty Coverage Included in contract negotiation, ideally 3-5 years if available Post-Warranty Support RCC or OEM, most logistically efficient Legacy Support Designated Overhaul Point establishment and/or ‘Fly-til-Fail’ with technology back-up or alternative/shift Obsolescence If requirement still exists, then process recycles
3
Known Life Cycle BITRs (Bumps In The Road)
Technical Measurement Requirement Definition Contracting and Procurement System developmental lead time may be insufficient to support fielding of TMDE in time for deployment schedules Technology may no longer be available or cost effective Obsolescence Warranty Coverage DRMO may not be option if capability still required but no longer supported by industry May not be of sufficient duration, cost effective, or OEM may not be willing to accept risk Legacy Support Post-Warranty Support Commercial & DoD infrastructure capabilities may not exist Maintainability of technology may be proprietary/unique
4
Activity Interaction NAVSEA TMDE SUPPLY
RMC Calibration Centers INPUT FEEDBACK NAVSEA TMDE Engineering & Lifecycle Logistics Team Defined Measurement Disciplines (Functional Groups) TYCOMS & FLEET REPS Individual System Assessment Grouped System Requirements RMCs (Subject Matter Experts) Categorized Measurement Requirements (SCATs) (Measurement Requirements) PS/E Acquisition Programs PS/E ISEAs SUPPLY (Purchase Description and Contract Award) TMRs
5
Functional Groups Signal Generator Digital Multimeters
Baseband Generator Synchro Resolver Spectrum Analyzer Calibrator Logic Analyzer Oscilloscope Voltmeter Frequency LAN/WAN Telcomm Analyzer Power Supply Bit Error Rate Tester Comm Analyzer Recorder Insulation Breakdown Power Analyzer Component Test Impedance Matcher Field Strength Noise Radar Test Set Modulation Analyzer Probe Power Meter Attenuator Fiber Optics Distortion Data Analyzer Electrical Safety Network Analyzer Resistor Scalar Analyzer Photo Tachometer Resistance Capacitor Amplifier Humidity Dummy Load Temperature Transformer Time/Freq-Domain Reflectometry Ph Phase Sequence Audio Analyzer Sound Level Termination Data Acquisition Modulator Adapter Coupler Detector Divider Filter Conductivity Earth Ground Echo Box Isolator Battery Analyzer PCB Test Impedance Vibration Oxygen Switch Potentiometer Mixer Power Limiter Antenna Inductor Torque Earth Ground Signature Analyzer Teletype Monitor
6
Model obsolete without immediate direct replacement.
Obsolescence Issues Model obsolete without immediate direct replacement. Model no longer on contract. OPN requirements forefront of identifying obsolete GPETE. Conflicting equipment availability reports. Vendors not being proactive in reporting model obsolescence.
7
Past Year Efforts 4017 METER RADIATION NBM-520+2 PRB 4019
SCAT_CD MOD_DESCP_ABBP_TX 4017 METER RADIATION NBM PRB 4019 METER RADIATION NBM-520+4PRBS 4025 ANALYZER LOGIC 102 CH 100MHZ 4115 POWER SUPPLY 50VDC 1.5AMPS 4122 OHMMETER HI-RESOLUTION 2K OHMS 4236 METER CLAMP-ON AC 1000A 700V 4245 MULTIMETER 3.5 DGT AC,DC 1000V 4249 MULTIMETER 4.5 DGT AC/DC 1000V 4306 OSCILLOSCOPE FOUR TRACE 400MHZ 4553 TESTER SEMICONDUCTOR IC 4584 ANALYZER VOICE FREQ HZ 5359 TORQUE CALIBRATOR 0-800FT-LB 4541 MEGOHMMETER V 100GOHM 4465 LAN CABLE TESTER 4405 GENERATOR, FUNCTION
8
In Progress SCAT_CD MODEL DESCPRIPTION 4070 SYNCHRO TESTER 60+400HZ
4195 VOLTMETER 0DB/1V U-1000V 4262 METER DEVIATION FM MHZ 4290 TIME DOMAIN REFLECTOMETER 4298 4341 ANALYZER SPECTRUM 99HZ-1800MHZ 4344 ANALYZER DISTORTION KHZ 4362 GENERATOR FM/AM 50KHZ- 550MHZ 4363 GENERATOR AM/FM 9KHZ-2GHZ 4473 ANALYZER ANTENNA MHZ 4475 ANALYZER NETWORK 10MHZ-110GHZ 4659 TRANSFORMER ISOLATION 4:1 5KHZ 4734 ANALYZER SPECTRUM KHZ 4940 POWER METER PK GHZ
9
Upcoming In process to evaluation next obsolescence SCAT codes for review. Possible candidates. SCAT 4349 Audio Analyzer SCAT 4466 Network Analyzer SCAT 4591 Bit Rate Error Tester SCAT 4567 Optiview II Network Analyzer SCAT 4573 Network Analyzer SCAT 4310 OTDR SM SCAT 4318 OTDR MM Fleet Input ___
10
CMRS The Calibration and Measurement Requirements Summary is a form used to document the measurements O-Level maintainers could be required to make on a specific Prime System, and to calculate the test equipment that will be required to support those measurements. Actual Prime System measurements are defined: Volts, Amps, MHz, RPM, etc. Required accuracies Unique conditional requirements (rare) Sufficiently capable test equipment is matched to each measurement using 4-to-1 Test Accuracy Ratio Sufficiently capable cal standard or procedure is matched to the test equipment listed (also 4:1 TAR) Category I Category II Category III
11
CMRS Responsibilities ISEAs/PEOs maintain Category I Data only
(Prime System) NAVSEA TMDE Team will maintain Categories II and III (Test Equipment and Cal Standards)
12
CMRS Documentation Once Prime System measurement requirements (Category I) are documented, NAVSEA completes remainder of CMRS. ISEA is then only responsible for updating O-level maintenance parameters when necessary.
13
Requirement Consolidation
NAVSEA uses consolidated CMRS data for all serviced PS/E to develop the best match of GPETE requirements to cost. PS/E #1 PS/E #2 PS/E #n Prime System Measurement Parameter Meas 1 (Volts) Meas 2 (Acc) Meas 3 (Res) Meas n System 1 850 Vdc 4 % < 3.4 V System 2 795 Vdc 5 % < 4 V System n 815 Vdc 10 % < 8.2 V ISEA- provided Category I data
14
The Bottom Line: Make use of GPETE whenever possible.
Once an ISEA completes the Category I data portion of the CMRS, NAVSEA then calculates and completes Category II and III. The complete CMRS for each system is then validated by the ISEA. Once validated, the responsibility to maintain a sufficiently capable and reliable inventory of GPETE and calibration standards rests with NAVSEA 04RM. Assuming the O-Level maintenance requirements for a given system do not change, the only further ISEA action in support of CMRS is to keep POC data current. NAVSEA will advise ISEAs when compatibility or technology advance/obsolescence compels a change in Category II equipment, and will resolve any needed shifts with the ISEA.
15
Over 120 CMRS completed to date
AN-BYK-6(V)1 CMRS AN_BYH-1 CMRS AN_BST-2 Cmrs form BSR-1 Cmrs Template AN-BSQ-9(V)4 CMRS AN_BSQ-9(V) CMRS AN_BRA-24 CMRS AN_BQQ-10(V)4 CMRS BLQ-10 CMRS AN_APX-118 Cmrs AN_USQ-172(V) CMRS BQH-9V1 Cmrs AN_SYQ-27 CMRS AN_SXY-1 CMRS AN_SSX-1 CMRS AN_SSQ-137(V) CMRS AN_SMQ-11D & E CMRS AN_SSH-9 CMRS AN_SSH-6 CMRS AN_SPQ-9 CMRS AN_SSW-2 CMRS
16
Questions?? Greg Hogan DSN 873
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.