Presentation is loading. Please wait.

Presentation is loading. Please wait.

Gerda phase II Front-End: resistorless ? BEGe or segmented detectors   electrode cap of a few pF Very FE to be placed very close to detector electrode.

Similar presentations


Presentation on theme: "Gerda phase II Front-End: resistorless ? BEGe or segmented detectors   electrode cap of a few pF Very FE to be placed very close to detector electrode."— Presentation transcript:

1 Gerda phase II Front-End: resistorless ? BEGe or segmented detectors   electrode cap of a few pF Very FE to be placed very close to detector electrode Mounting of the front-end devices in the style used in ultra low noise X-ray spectrometers might be appropriate in order to exploit det low capacitance FE devices include FET, C F, C TEST, R F. Chip resistors in the G  range have the poorest radio purity  a resistorless preampliflier could be best suited A few devices are mounted very close to the electrode, while the remaining part of the preamplifier is placed at some distance as connected with thin twisted-pair or coaxial cables

2 Resistorless preamplifiers in literature Low-noise charge preamps with no feedback resistor are found in literature as developed for X-ray spectroscopy How does the feedback capacitance get discharged ? 1.FBF. This solution uses the gate-to-source forward biased FET junction to provide discharge current path (G.Bertuccio, P. Rehak, D. Xi, NIM A326, pp. 71-76, 1993) 2.BJT. This solution uses the transversal parasitic BJT of dual gate FET’s to provide discharge current path (P. Rehak, A. Fazzi, NIM A439, pp. 391-402, 2000) 3.MOSFETa. This solution uses a MOSFET in weak inversion in parallel to CF (P.O’Connor, G. Gramegna, P. Rehak, et al, IEEE Trans. Nucl. Sci, vol. 44, no. 3 pp. 318-325, 1997) 4.MOSFETa + NL P/Z. This solution adds a non-linear Pole-Zero (P/Z) compensation to previous solution (G. Gramegna, P. O’Connor, P. Rehak, S. Hart, NIM A390, pp. 241-250, 1997) 5.MOSFETb. This solution uses a MOSFET to discharge CF through a negative feedback loop (B. Ludewigt, J. Jaklevic, I. Kipnis, et al, IEEE Trans. Nucl. Sci., vol. 41, no. 4, 1994) 6.PULSED. This solution forces the preamplifier reset when its output crosses a preset threshold, or at fixed clocked times

3 Resistorless preamplifiers in literature 1 and 2 are easy-to-implement as discrete-component circuits 3, 4 and 5 are integrated circuits 6 can be realized with discrete components or as an integrated circuit None of the shown circuits has been tested at cryogenic temperatures

4 Resistorless preamplifiers in literature Problem:  -ray spectroscopy requires much better linearity than X-ray spectroscopy. Can existing resistorless solutions be used ? Solution 4 shown in the list is the best candidate as it uses a technique to eliminate the nonlinearities of the reset device A study on existing/new solutions for resistorless charge preamplifiers suited for  -spectroscopy is needed and challenging

5 Resistorless preamplifiers in literature Technical details can be found in the quoted papers 1 2 3 4 5 ENC=19 el rms ENC=13 el rms ENC=9 el rms ENC=40 el rms ENC = 19 el rms


Download ppt "Gerda phase II Front-End: resistorless ? BEGe or segmented detectors   electrode cap of a few pF Very FE to be placed very close to detector electrode."