Presentation is loading. Please wait.

Presentation is loading. Please wait.

ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 1

Similar presentations


Presentation on theme: "ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 1"— Presentation transcript:

1

2 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 1
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 1 You receive 2 boxes for each metal detector: Main Control & Display Unit Side Panels (Left&Right)

3 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan When you open the boxes:
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan When you open the boxes: Main Control & Display Unit Back Fixing Unit Left Side Panel Right Side Panel 2

4 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 3
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 3 Assembling Back Fixing Unit 4 Other side

5 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan Screw up the rear cover of the Main Control & Display Unit. 5

6 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 7 For the sockets:
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 7 For the sockets: ThruScan is designed to prevent false connector/socket connection. Left Panel – female D-Sub 25 Mains Socket - SRC- D-Sub 9 Right Panel – male D-Sub 25 6

7 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan Screw down the Main Control & Display Unit. Fix strongly to the side panels. 8 9

8 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 11 10
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 11 10 Lift up your ThruScan Fasten the black blind taps

9 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 12
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 12 Plug in the connectors.

10 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 13
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan Right Side Panel Connector Mains Connector (from left side panel) 13 Left Side Panel Connectors Impossible to make mistake… 14

11 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 15
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 15 Close the rear cover of Main Display & Control Unit.

12 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 16
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan Adjust the distance between side panels to 76 cms. 16

13 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 18 17
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 18 17 Mark the positions of side panel holders.

14 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 19 20
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 19 20 Drill & Fix the side panel holders to the ground – stable conditions. 21 22

15 ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 23
You need 15 minutes for assembling!... Get User’s Manual PLS. Download from our web-site: ASSEMBLING & MOUNTING ThruScan 23 Put your ThruScan into the side panel holders inside and screw the bolts. 25 24

16 ELEKTRAL A.S. CONTROL PANEL OF ThruScan Metal Detectors TOUCH PADS
OFF BUTTON ON BUTTON BATTERY INDICATOR LCD DISPLAY 4*20 RUN BUTTON SEL UP DOWN ALARM LOCATOR LED VU DISPLAY TOUCH PADS PACING LIGHT INDICATOR

17 ELEKTRAL A.S. MULTI POINT INDICATOR LIGHTS ENTRANCE- Traffic Lights
Led illuminated Warning Displays on Zones

18 ELEKTRAL A.S. RELAY CONTACT OUTPUTS RELAY CONTACT OUTPUTS
Provides to control CCTV Cameras, Turnstiles, Gates…etc. SYNC & REMOTE CONTROL OUTPUTS For tandem operation or SRC- Scada Remote Control

19 ELEKTRAL A.S. PROGRAMMING & SETUP Normal Operating Screen IN OUT
(When you swich on – the screen) IN OUT SECURITY LEVEL 03 To enter the program menu Press ENTER PASSWORD [0---] If the correct password is entered display will change to: SECURITY LEVEL LEVEL 02 If the password is incorrect: SECURITY LEVEL PASSWORD ERROR

20 ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS
ThruScan s9 has 10 seperate SECURITY LEVELS ThruScan sX has 20 seperate SECURITY LEVELS SECURITY LEVEL LEVEL 02 It is possible to adjust a total of 246 sensitivity levels from security level 000 (highest sensitivity) to 245 (lowest sensitivity) ThruScan s9 SECURITY LEVEL LEVEL [02]=20 SECURITY LEVEL SENSITIVITY ADJUSTMENT Security Level (NC) NILECJ – Level 2 (factory fixed) Security Level 1 010 Security Level 2 020 Security Level 3 030 Security Level 4 050 Security Level 5 100 Security Level 6 140 Security Level 7 180 Security Level 8 220 Security Level 9 230

21 ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS
ThruScan sX SECURITY LEVEL SENSITIVITY ADJUSTMENT Security Level (NC) NILECJ – Level 2 (factory fixed) Security Level 1 010 Security Level 2 020 Security Level 3 030 Security Level 4 040 Security Level 5 050 Security Level 6 060 Security Level 7 070 Security Level 8 080 Security Level 9 090 Security Level 10 100 Security Level 11 110 Security Level 12 Security Level 13 Security Level 14 Security Level 15 Security Level 16 Security Level 17 Security Level 18 Security Level AD 120 140 160 180 200 220 240 030 – Auto Designation/AD SECURITY LEVEL LEVEL 02 SECURITY LEVEL LEVEL [02]=20 SECURITY LEVEL LEVEL [15]=180

22 ELEKTRAL A.S. You can make fine tunning here: 185 IN OUT
Between 000(highest sebsitivity) – 245(lowest sensitivity) SECURITY LEVEL LEVEL [15]=180 IN OUT SECURITY LEVEL 03 ENTER PASSWORD [0---] SECURITY LEVEL LEVEL [02] SECURITY LEVEL LEVEL 02 SECURITY LEVEL LEVEL [15]

23 ELEKTRAL A.S. Normal Operating Mode Other Menus SECURITY LEVEL

24 ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL,
ZONE ADJUSTMENTS for ThruScan sX The sensitivity levels of zones can be adjusted separately. The sensitivity level of zone 2 in which there would more likely be keys, cell phones, belts etc. can be decreased while the other zones’ can be increased. * 5 IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL [02] SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL 02 * 1 Other Menus ZONE=2 ZONE=3 INDIVIDUAL ZONE SENS SECURITY LEVEL LEVEL [02] ZONE=[01] Normal Operating Mode ZONE [01]=20

25 ELEKTRAL A.S. AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN for ThruScan sX This menu is to help the user to decide and to assign the required sensitivity level very rapidly. * 5 * 2 AUTO DESIGNATE MODE IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL /2 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL /1 USED FOR AUTO DESIGNATE OF SECURITY LEVEL TO CONTINUE PRESS SEL 01 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL /3 DESIGNATE-DETECTMOD ALL ZONES 00 ZONE 01 [00] 00

26 ELEKTRAL A.S. AUTO DESIGNATION MODE - continue 01 IN OUT
AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL ZONE [01] DESIGNATE-DETECTMOD ALL ZONES 00 ZONE 01 [53] SELECT THE ZONE AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL ZONE [01]=53 AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL LEVEL [AD]=53 AUTO DESIGNATE MODE IN OUT SECURITY LEVEL 03

27 ELEKTRAL A.S. ALARM VOLUME ADJUSTMENT * 5 * 3 IN OUT
ThruScan s9-sX has 10 separate alarm volume levels, 1 quietest – 10 loudest – 00 Mute If you want different tones, pls mention with your order. It has 10 different tones in the menu. * 5 * 3 ALARM VOLUME 0<=>10 IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 ALARM VOLUME 0<=>10 VOLUME=10 ALARM VOLUME 0<=>10 VOLUME=05

28 ELEKTRAL A.S. ALARM COUNTER * 5 * 4 IN OUT MENU SECURITY LEVEL
00012 IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE ALARM COUNTER 00012 RESET Y <=> N N MENU ALARM COUNTER 00000 ALARM COUNTER 00012 RESET Y <=> N Y

29 ELEKTRAL A.S. IN – OUT COUNTER (TRAFFIC COUNT) * 5 * 5 IN OUT MENU
99999………………….…01977 IN>-COUNTER-<OUT IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE 99999………………….…01977 IN>-COUNTER-<OUT ACTIVE =00 00 – Do not reset 01 – Reset In Count 02 – Reset Out Count 03 – Reset Both Counters MENU

30 ELEKTRAL A.S. FACTORY SETTINGS * 5 * 6 IN OUT MENU
ThruScan s9-sX can be returned to factory setting by this menu. * 5 * 6 FACTORY SETTINGS Y<==>N IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE FACTORY SETTINGS Y<==>N ACTIVE =N Y – FACTORY RESET N – DO NOT RESET MENU

31 <===================>
ELEKTRAL A.S. LANGUAGE SELECTION ThruScan s9-sX can be operated in 4 languages- EN-DE-SPA-TR * 5 * 7 LANGUAGE ENGLISH IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE LANGUAGE ENGLISH <===================> ENGLISH DEUTSCH TURKCE ESPANOL MENU

32 ELEKTRAL A.S. COUNTER VISIBILITY * 5 * 8 IN OUT IN OUT MENU
ThruScan s9-sx’ Normal Operating Mode-Menu Displaycan be inhibited. * 5 * 8 COUNTER VISIBILITY Y<==>N IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE COUNTER VISIBILITY Y<==>N ACTIVE =Y N – DISPLAY OFF Y – DISPLAY ON MENU IN OUT ***** ***** SECURITY LEVEL 03

33 ELEKTRAL A.S. ENVIRONMENT NOISE LEVEL * 5 * 9 IN OUT MENU
This menu is prepared to measure the electromagnetic noise level in the environment in which the ThruScan was placed and help the user with the sensitivity level assignment. * 5 * 9 ENVIRONMENTAL NOISE LEVEL IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NORMAL OPERATING MODE ENVIRONMENTAL NOISE LEVEL NOISE = 003 MENU

34 ELEKTRAL A.S. NEW PASSWORD * 5 * 10 IN OUT MENU
You can change your 4 digit pin-code as follows: Let’s make password 1978 * 5 * 10 NEW PASSWORD [ ] IN OUT SECURITY LEVEL 03 SECURITY LEVEL LEVEL [02]=20 NEW PASSWORD [ ] NEW PASSWORD [ 1 * * * ] NEW PASSWORD [ 0 * * * ] 1 2 3………. 8 9 1 2 3………. 8 9 NORMAL OPERATING MODE MENU


Download ppt "ELEKTRAL A.S. ASSEMBLING & MOUNTING ThruScan 1"

Similar presentations


Ads by Google