5/10/20101GlueX Col meeting, A. Gasparian1 The PrimEx HyCal Calorimeter A. Gasparian NC A&T State University, Greensboro, NC Outline HyCal calorimeter PbW0 4 detectors Resolutions Transition region
2
5/10/20102 The PrimEx HyCal Calorimeter 1152 PbWO4 individual crystal detectors (70 x 70 cm 2 insertion) GlueX Col meeting, A. Gasparian 576 Lead Glass detectors
3
5/10/20103 The HYCAL Calorimeter (Crystal part) GlueX Col meeting, A. Gasparian
4
Calor-2004, March 30A. Gasparian4 PbWO 4 Crystal Dimensions Geometrical size: 20.5 x 20.5 x 180.0 mm 3 Tolerances (mm): 20.5 + 0.0 - 0.1 180.0 + 0.3 -0.0 Specified Measured
5
Calor-2004, March 30A. Gasparian5 PbWO 4 : Optical Properties
6
8/29/20156 PbWO 4 : Position Resolution vs. Energy Detector characteristics and resolution have been done in different ways: with secondary electron beam (PS in Hall B); with low intensity tagged photon beam (Hall B tagger) σ =2.7 mm @ 1. GeV
7
8/29/20157 PbWO 4 : Position Resolution vs. impact coordinate
8
8/29/20158 Lead-Glass: Position Resolution vs. Energy σ =5.6 mm @ 1. GeV
9
8/29/20159 PbWO 4 : Energy Resolution vs. Energy σ =2.45% @ 1. GeV
10
8/29/201510 Lead-Glass: Energy Resolution vs. Energy σ =5.7% @ 1. GeV
11
8/29/201511 Transition Region: PbWO 4 - Lead-Glass
12
8/29/201512 Transition Region: PbWO 4 - Lead-Glass Reconstructed Coordinate
13
8/29/201513 Transition Region: PbWO 4 - Lead-Glass Reconstructed Coordinate (E γ = 5.2 GeV)
14
8/29/201514 Transition Region: PbWO 4 - Lead-Glass Position Resolution (E γ = 5.2 GeV)
15
8/29/201515 Transition Region: PbWO 4 - Lead-Glass Reconstructed Energy (E γ = 5.2 GeV)
16
8/29/201516 Transition Region: PbWO 4 - Lead-Glass Energy Resolution (E γ = 5.2 GeV)
17
5/10/201017 Sensitivity to Magnetic Field GlueX Col meeting, A. Gasparian Possible modifications: change the G10 housing to sift ion housing and extend it to ~1” insert optical extension extend the brass strips (look at different options first) No need to change the optical wrapping The current design do not have extended µ-metal on photocathode Try to shield the FCAL frame with some µ-metal, if it is all possible
18
5/10/201018 Summary The Hybrid Calorimeter concept have been successfully reapproved with the HyCal calorimeter in the PrimEx experiment. Technical and methodical aspects of the Hybrid calorimeter are well understood and tested. On-site expertise is available. HyCal is equipped with ~2000 channel power supply (CAEN) unit; Trigger and analog electronics are old. 1152 PbWO 4 high resolution, radiation hard crystal detectors are available for future experiments. HyCal will stay in Hall B up to the end of PrimEx-II experiment. GlueX Col meeting, A. Gasparian
19
5/10/201019A. GasparianGlueX Col meeting, A. Gasparian19 The End
20
8/29/201520 Invariant Mass Resolution PbWO 4 only Pb-Glass only