Investigations on Dodecagonal Space Vector Generation for Induction Motor Drives Presented by Anandarup Das CEDT, IISc, Bangalore.

Similar presentations


Presentation on theme: "Investigations on Dodecagonal Space Vector Generation for Induction Motor Drives Presented by Anandarup Das CEDT, IISc, Bangalore."— Presentation transcript:

1 Investigations on Dodecagonal Space Vector Generation for Induction Motor Drives
Presented by Anandarup Das CEDT, IISc, Bangalore

2 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Flow of presentation Motivation for the present research. Schemes to be presented Hybrid space vector PWM strategy in linear and over-modulation region involving hexagonal and dodecagonal space vector diagrams. Development of two concentric dodecagons using conventional 3-level inverters with capacitor balancing. Further refinement of the above space vector structure into multiple 12-sided polygons with conventional 3-level inverters. Modulation strategies and PWM timing calculation of the above schemes. Discussion on experimental verification Steady state operation. Transient results with motor accelerated upto rated speed with open-loop V/f control Harmonic performance of phase voltage and phase current under these conditions Conclusion CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

3 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Motivation for the present research Multilevel inverters are popular for high power drives because of low switching losses and low harmonic distortion in the output voltage. In many multilevel inverter fed high power drives, the switching frequency of the inverter is limited because of large dv/dt stress on the devices and the motor and higher switching losses. However, with low switching frequency, lower order harmonics e.g. 5th and 7th order can be a considerable percentage of the total current, in particular during over-modulation and 6-step operation. So a trade-off is required to maintain the quality of the inverter output voltage without resorting to higher switching frequency. In this regard, a dodecagonal space vector diagram is very desirable that eliminates all the 5th and 7th order harmonics from the phase voltage, leaving the next set of harmonics at (12n±1), n=integer. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

4 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Evolution of space vector structures (Hexagonal and 12-sided) Hexagonal space vectors. 2-level 3-level 5-level 12-sided polygonal space vectors. O 1 2 5 6 7 8 9 10 11 12 4 3 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

5 Proposed research schemes
In the proposed work, a multilevel inverter topology is described which produces hexagonal space vector diagrams in lower-modulation region and a dodecagonal space vector structure in the higher modulation region. In another scheme, a multilevel voltage space vector structure with vectors on the dodecagon is generated by feeding an open-end winding IM drive by two three level inverters. In a third scheme, a high resolution PWM technique is proposed involving multiple dodecagonal space vector structures, that can generate highly sinusoidal voltages at a reduced switching frequency. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

6 Part-1 A Combination of Hexagonal and Dodecagonal Voltage Space Vector Diagram for Induction Motor Drives

7 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Evolution of space vector structures (Hexagonal and 12-sided) Hexagonal space vectors. 2-level 3-level 5-level 12-sided polygonal space vectors. 4 5 3 6 2 7 1 O 8 12 9 11 10 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

8 Voltage space vector diagram of the proposed scheme
End of linear modulation Consists of four concentric hexagonal diagrams with different radii (0.366kVdc , 0.634kVdc , 1kVdc and 1.366kVdc). Operates in the inner hexagons at lower voltage to retain the advantages of multilevel inverter like low switching frequency. At higher voltage, the outermost hexagon and the 12-sided polygonal space vector structure is used resulting in highly suppressed 5th and 7th order harmonics. The leads to 12-step operation at rated voltage operation, leading to the complete elimination of 6n±1 harmonics. (n=odd) from the phase voltage. OE: 1.225kVdc CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

9 Consists of three cascaded 2-level inverters
Inverter Topology Consists of three cascaded 2-level inverters Two inverters are supplied with a dc bus of kVdc while the third one is supplied with a dc bus of kVdc. C D A Switch status for different levels of pole voltage R-phase Pole voltage Level S11 S21 S31 1.366kVdc 3 1 1.0kVdc 2 0.366kVdc 0Vdc B O Pole voltage of overall inverter-vAO Pole voltage of INV3- vBO Pole voltage of INV2-vAB Pole voltage of INV1-vCD CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

10 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Transformer connection for generation of 12-sided polygonal voltage space vector Asymmetric DC-links are easily realized by a combination of star-delta transformers, since 0.634kVdc=√3 x 0.366kVdc. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

11 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Comparison with hexagonal space vector structure The modulation index (m), is defined as the ratio of the length of the reference vector to the length of the radius of the dodecagon. m = in linear modulation and m =1 at 12-step operation. Here, the radius of the dodecagon is 1.225kVdc.Thus the maximum fundamental phase voltage available from this space vector diagram is 0.806kVdc (in 12-step). It is known that, the maximum fundamental voltage available from a conventional hexagonal space vector diagram in 6-step mode is 0.637Vdc and equal to 0.577Vdc at the end of linear modulation. For comparison purpose, if the maximum fundamental voltage available in 6-step mode and 12-step mode are made equal to 0.637Vdc, then ‘k’ = 0.637/0.806=0.789. For k = 0.789, the maximum phase voltage available here in linear modulation is 0.615Vdc and equal to 0.637Vdc in 12-step mode of operation. There is hence an increase in linear modulation range. Radius of dodecagon radius= 1.225kVdc CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

12 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Modulating waveform The modulating waveform for phase-A for 35Hz operation (linear modulation range) is shown. The modulating waveform is synchronized with the start of the sector (sampling interval is always a multiple of twelve). Because of asymmetric voltage levels, three asymmetric synchronized triangles are used; their amplitudes are in the ratio 1:√3:1. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

13 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Switching sequence analysis Three pole voltages are shown for a 60 degree interval at 35Hz operation. Level shifted SVPWM is used here. In ‘A’ phase the voltage level fluctuate between levels ‘3 ’ and ‘2 ’, and in ‘C’ phase the voltage level fluctuates between levels ‘1 ’ and ‘0 ’. The sequence in which the switches are operated are as follows: (200), (210), (211), (311), (321), (311), (211), (210), (211), (311), (321), (211), (221), (321), (221), (210), (220), (221), (321), (331), (221), (220), where the numbers in brackets indicate the level of voltage. This sequence corresponds to 2 samples per sector. There are altogether 12 sectors spanning from 00 to 300, 300 to 600 and so on. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

14 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental Setup A digital signal processor (DSP), TMS320LF2812 is used for experimental verification. For different levels of output in the pole voltage, three carriers are required. However, it is difficult to synthesize three carrier waves in the DSP, as such only one carrier is used and the modulating wave is appropriately scaled and level shifted. A 3.7kW induction motor was fed by the proposed inverter operating under open loop constant V/f control at no load. The motor was made to run under no load in order to show the effect of changing PWM patterns of the generated voltage on the motor current, particularly during transient conditions. In order to keep the overall switching frequency within 1 KHz, number of samples is decided as follow: Upto 20 Hz operation: 4 samples per sector. 20 Hz-40 Hz: 2 samples per sector. Beyond 40 Hz: 1 sample per sector-extending up to final 12-step mode. Individual inverters are switched less than half of the total cycle. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

15 Experimental results-Operation at 10 Hz
Normalized harmonic spectrum of Phase voltage Phase current Phase voltage Phase current Phase voltage and current waveforms Switching happens within the innermost hexagon space vectors. As seen from the pole voltage waveforms, only the lower inverter is switched while the other two inverters are off, hence the switching loss is low. Four samples are taken in each sector, so INV3 switching frequency is (12x4X10=480Hz). The first carrier band harmonics also reside around 48 times fundamental. [Space Vector] Overall inverter INV3 [Inverter Topology] INV2 INV1 Pole voltage waveforms CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

16 Experimental results-Operation at 30 Hz
Normalized harmonic spectrum of Phase voltage Phase current Phase voltage Phase current Phase voltage and current waveforms The space vectors that are switched lie on the boundaries of the second and third hexagon from the center. Number of samples are reduced from four to two, thus switching frequency is (fs=12X2x30=720Hz). INV3 and INV1 are switched about 1/3rd of the total cycle, while INV2 is switched about 20% of the cycle. Overall inverter [Space Vector] INV2 INV2 switches INV3 INV1 Pole voltage waveforms [Inverter Topology] CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

17 Operation at 47 Hz ( end of linear modulation range)
Normalized harmonic spectrum of Phase voltage Phase current Phase voltage Phase current Phase voltage and current waveforms Overall inverter One sample is taken at the start of a sector, so switching frequency is only around (12X47=564Hz). The space vectors that are switched lie between the outer hexagon and the 12-sided polygon. INV2 INV3 INV1 [Space Vector] Pole voltage waveforms CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

18 Operation at 50 Hz ( 12-step operation)
Normalized harmonic spectrum of Phase voltage Phase current Phase voltage Phase current Phase voltage and current waveforms Complete elimination of 6n±1 harmonics (n=odd) from the phase voltage. One sample is taken at the start of a sector (fs=12X1x50=600Hz). Each inverter is switched only once in a cycle. Overall inverter INV2 INV3 INV1 Pole voltage waveforms Inverter Topology CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

19 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Input current at 50 Hz ( 12-step operation) Phase voltage Phase current Input phase voltage Input line current The input current to the inverter is not peaky in nature, because of the presence of the star-delta transformers. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

20 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Motor acceleration with open loop V/f Control Phase voltage Phase current Transition of motor phase voltage and current from 24 samples to 12 samples per cycle at 40Hz Transition of motor phase voltage and current from outermost hexagon to 12-step operation. Because of the suppression of the 5th and 7th order harmonics, the motor current changes smoothly during the transition when the number of samples per sector is reduced from two to one at 40Hz operation. As the speed of the motor is further increased, the inverter switching states pass through the inner hexagons and ultimately the phase voltage becomes a 12-step waveform. Under all operating conditions, the carrier is synchronized with the start of the sector. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

21 Harmonic performance of phase voltage and current
Total Harmonic Distortion upto 100th harmonic Harmonic performance of phase voltage and current 10Hz 30 Hz Hz 50Hz Voltage THD 57.59% 27.51% 14.67% 17.54% Voltage WTHD 0.81% 0.7% 0.97% 1.04% Current THD 12.31% 10.59% 15.6% 19.54% Current WTHD 0.28% 0.45% 1.2% 1.5% It is seen that voltage WTHD is quite low for all the operating conditions, as such the torque pulsation and harmonic heating in the machine is minimized. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

22 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Comparison with conventional structures A simplified comparative study is made between the proposed topology and the existing multilevel inverter configurations viz. 3-level NPC and 4-level NPC inverters used for induction motor drives. The conduction and switching losses incurred in the inverter, and motor phase voltage harmonic distortions are numerically calculated by computer simulation for comparison. A linear turn-on and turn-off switching profile is used for loss calculation. Losses incurred in snubber circuits, protection circuits, gate drives and due to leakage currents are neglected. A 2.3kV, 373kW induction motor is driven by a 3-level NPC, 4-level NPC and the proposed inverter. The inverter drives the induction motor under full load condition at around 0.85 p.f. lagging. Numbers of samples in a cycle are taken as 24. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

23 Square wave mode of operation
Loss comparison with conventional structures Phase voltage WTHD IGBT Switching loss IGBT Conduction loss Conduction loss in anti-parallel diodes Clamping diode conduction loss Total Loss unit % W 40 Hz Linear modulation 3-level NPC 0.68 95 2180 272 240 2787 4-level NPC 0.46 61 2400 414 350 3225 Proposed Inv 96 1884 306 2286 48 Hz Over modulation 1.22 27 2370 165 130 2692 0.89 20 2616 243 169 3049 0.55 25 1995 207 2227 50 Hz Square wave mode of operation 4.64 6 2511 184 2701 12 2730 258 3000 1.04 10 2034 180 2224 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

24 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Observations The phase voltage WTHD for the proposed inverter shows considerable improvement, particularly at higher modulation indices and the 12-step mode of operation, because of the suppression or elimination of the 6n±1 (n=odd) harmonics. Conduction losses are more dominant than switching losses for IGBT made inverters. As such, presence of the clamping diodes in NPC inverters increases the total losses of the inverter. The proposed inverter does not have any clamping diode and is devoid of any such losses. The switching losses also remain low for the proposed inverter. It is seen that the conduction losses in the proposed inverter are always less than the conventional inverters. This is because in the proposed inverter, for any ‘level’ of pole voltage output, two current carrying switches remain in conduction. This is not always the case in NPC inverters; e.g. for a four level inverter, at higher modulation indices, three switches per phase carry the phase load current when the total dc bus voltage is obtained at the pole. Conduction losses in the proposed inverter are further less in over-modulation region because of the fact that the r.m.s. current in the inverter is less compared to conventional NPC inverters, due to the suppression or elimination of the 6n±1 (n=odd) harmonics. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

25 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Synopsis A multilevel inverter topology is described which produces hexagonal space vector structures in lower-modulation region and a dodecagonal space vector structure in the higher modulation region. In the extreme modulation range, voltage vectors at the vertices of the outer dodecagon and the vertices from the outer most hexagon is used for PWM control, resulting in highly suppressed 5th and 7th order harmonics thereby improving the harmonic profile of the motor current. This leads to the 12-step operation at 50Hz where all the 5th and 7th order harmonics are completely eliminated. At the same time, the linear range of modulation extends upto 96.6% of base speed. Because of this, and the high degree of suppression of lower order harmonics, smooth acceleration of the motor upto rated speed is possible. Apart from this, the switching frequency of the multilevel inverter output is always limited within 1 kHz. The middle inverter ( high voltage inverter) devices are switched less than 25% of the output fundamental switching period. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

26 Part-II Generation of Multilevel Dodecagonal Space Vector Diagram

27 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Evolution of space vector structures (Hexagonal and 12-sided) Hexagonal space vectors. 2-level 3-level 5-level 12-sided polygonal space vectors. 4 5 3 6 2 7 1 O 8 12 9 11 10 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

28 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Multilevel dodecagonal space vector diagram This is an extension of the single dodecagonal space vector structure into a multilevel dodecagonal structure. Compared to conventional dodecagonal space vector structure, the device ratings and dv/dt stress on them are reduced to half. The switching frequency is also reduced to maintain the same output voltage quality. Here the added advantage is the complete elimination of 6n±1 harmonics, n=odd, from the phase voltage throughout the modulation index. The linear modulation range is also extended compared to the hexagonal structure. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

29 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Multilevel 12-sided polygonal space vector structure Consists of two concentric dodecagonal space vector structures. Unlike conventional hexagonal multilevel structure, here the sub-sectors are isosceles triangles rather than equilateral triangles. Each sector is thus divided into four sub-sectors as shown. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

30 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Inverter Structure In order to realize the proposed space vector structure, two conventional three level NPC inverters are used to feed an open ended induction motor. The two inverters are fed from asymmetrical dc voltage sources which can be obtained from the mains with the help of star-delta transformers and uncontrolled rectifiers. Because of capacitor voltage balancing of the NPC inverters, only two dc sources are used. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

31 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Switching state combination for realizing space vector 16 INV1 produces vector X(220) while INV2 produces vector Y(0’2’2’). When they are combined, the resultant vector Z(220, 0’2’2’) is produced. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

32 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Timing calculation for dodecagonal space vector locations Here, the timings for which adjacent vectors are switched are obtained as, This is similar to conventional space vector PWM. However, this requires calculation of sine values through a look-up table, which takes unnecessary memory and time in a DSP. A better algorithm has been generated which can calculate the timings by sampling six reference rotating phasor. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

33 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Timing relation among different space vectors V2, T2 Instead of vectors on the vertices of the sector, three nearest enclosing vectors are now switched. This is done to achieve multilevel switching. The time durations for which the original vectors need to be switched is modified. The new timing durations are achieved by volt-second balance. The timing relation can be extended to other sub-sectors. V4, T’2 V’1, T’0 V1, T’1 V1, T1 Point Switched for V1 T1 V2 T2 O T0 Point Switched for V1 T’1= 2T1-TS V4 T’2 = 2T2 V’1 T’0 = 2T0 Note: T’0 >= 0. T1+T2+T0= T’1+T’2+ T’0=TS. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

34 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Capacitor balancing scheme The inner dodecagonal space vectors (points 1-12) have four multiplicities which are complementary in nature in terms of capacitor balancing. The outer dodecagonal space vectors ( points 13-36) either do not cause any capacitor unbalancing, or have complementary states to maintain capacitor balancing. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

35 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Inner 12-sided polygon-switching multiplicities for point-1 C2 is discharged, C4 is charged. C1 is discharged, C4 is charged. C1 is discharged, C3 is charged. C2 is discharged, C3 is charged. The four switching multiplicities are complementary in nature in terms of capacitor balancing. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

36 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Outer 12-sided polygon-switching multiplicities Point-13, two multiplicities C3 is discharged, C1 & C2 are undisturbed. C4 is discharged, C1 & C2 are undisturbed. Point-14: no multiplicity, no capacitor disturbance Point-36: no multiplicity, no capacitor disturbance CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

37 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-15 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current Four samples are taken in each sector and switching takes place entirely in the inner 12-sided polygon. The phase voltage harmonics reside at 15x12x4=720 Hz, which is 48 times the fundamental. However, the switching frequency of the pole voltage of INV1 is (24x15=) 360Hz, while that of INV2 is (32x15=) 480Hz. The higher voltage inverter switches about 50% of the cycle. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

38 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-23 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current Three samples are taken in each sector and switching takes place at the boundary the inner 12-sided polygon. All the 6n±1 harmonics, n=odd, are absent from the phase voltage, while the rest are highly suppressed. The switching frequencies of the pole voltage of INV1 and INV2 are respectively (18x23=) 414Hz and (24x23=) 552Hz, with output phase voltage switching frequency at 828Hz (=23x12x3). CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

39 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-40 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current Two samples are taken in each sector and switching takes place between the inner and outer dodecagons. This is also seen in the phase voltage waveform, since the outer envelope of the waveform at lower frequency becomes the inner envelope at higher frequency. The harmonic spectrum of the phase voltage and current shows the absence of peaky harmonics throughout the range. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

40 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-48 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current This is the end of the linear modulation of operation. Here the number of samples per sector is two, as such the switching frequency sidebands reside around 24 times the fundamental. The switching frequency of the pole voltages of INV1 and INV2 is respectively (48x12=) 576Hz and (48x16=) 768Hz, with an output phase voltage switching frequency of 1152Hz (48x12x2). CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

41 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-49.9 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current At the end of end over-modulation region, 24 samples are taken in a sector, corresponding to the vertices of the polygon. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

42 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-50 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current This is the 12-step operation, where one sample is taken at the start of a sector. The phase voltage and current is completely devoid of any 5th and 7th order harmonics. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

43 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Total Harmonic Distortion upto 100th harmonic Harmonic performance of phase voltage and current Voltage THD Voltage WTHD Current THD Current WTHD 15Hz 75.4% 1.48% 24.49% 0.56% 23Hz 21.2% 0.54% 9.19% 0.48% 40Hz 24.85% 0.71% 12.08% 0.65% 48Hz 9.67% 0.33% 5.52% 0.26% 49.9Hz 7.26% 0.28% 4.68% 0.24% 50Hz 17.54% 1.04% 19.54% 1.5% It is seen that voltage WTHD is quite low for all the operating conditions, as such the torque pulsation and harmonic heating in the machine is minimized. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

44 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Acceleration of the motor Phase voltage Phase current Transition of motor phase voltage and current from inner to outer 12-sided polygon Transition of motor phase voltage and current from over-modulation to 12-step operation. In both the cases, the motor current changes smoothly as the motor accelerates. This happens because of the use synchronized PWM and total elimination of 6n±1 harmonics, n=odd, from the phase voltage throughout the modulation index. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

45 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental Results-capacitor unbalancing at 20 Hz Capacitor unbalance is done at steady state with the motor running at 20 Hz speed. Both side capacitors are deliberately unbalanced and after some time controller action is taken. Vc1, Vc2 Vc3, Vc4 Deliberate unbalancing Controller action taken C1,C2 : higher voltage side capacitors C3,C4 : lower voltage side capacitors CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

46 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental Results-capacitor unbalancing at 40Hz Both the sides are made unbalanced at the same time and are seen to come back to the balanced state. Compared to the 20 Hz case, it requires more time to restore voltage balance, since the number of multiplicities in the outer polygon is less. Vc1, Vc2 Vc3, Vc4 Controller action taken Deliberate unbalancing C1,C2 : higher voltage side capacitors C3,C4 : lower voltage side capacitors CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

47 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Synopsis An improved space vector diagram is proposed here that is composed of of two concentric dodecagons. It reduces the device rating and the dv/dt stress on the devices to half compared to existing 12-sided schemes. The entire space vector diagram is divided into smaller sized isosceles triangles. PWM switching on these smaller triangles reduces the inverter switching frequency without compromising on the output voltage quality. The proposed topology is realized by feeding an open-end induction motor with two conventional 3-level NPC inverters, where, the high voltage inverter always switches at nearly half the output phase voltage switching frequency. Additionally, the mechanism for capacitor balancing, using switching state redundancies is also proposed for the full modulation range CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

48 Part-III A Voltage Space Vector Diagram Formed By Six Concentric Dodecagons

49 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Evolution of space vector structures (Hexagonal and 12-sided) Hexagonal space vectors. 2-level 3-level 5-level 12-sided polygonal space vectors. 4 5 3 6 2 7 1 O 8 12 9 11 10 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

50 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Space Vector Structure The space vector diagram consists of six concentric dodecagonal structures - A, B, C, D, E and F. These are grouped as type-1 and type-2 dodecagons, where type-2 dodecagons (A, C and E) lead type-1 dodecagons (B, D and F) by 150. The radii of these polygons are in the ratio r1: r2: r3: r4: r5: r6 = 1: cos (π/12): cos (2π/12): cos (3π/12) :cos (4π/12) :cos (5π/12). The entire space vector diagram is divided into 12 sectors each of width 300. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

51 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Evolution of the present space vector diagram CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

52 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Power Circuit of the Inverter The power circuit of the inverter consists of 2 three level NPC inverters feeding an open end induction motor. These two inverters are fed from isolated dc voltage sources having voltage ratio of 1: This ratio of voltages is obtained from a combination of star delta transformers since 1:0.366= (√3+1):1. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

53 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Realization of space vector 27 Point 27 can have two switching combinations- (110,002) or (221,002). CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

54 Benefits of the proposed scheme
Here the space vector plane is divided into six dodecagonal structures. Switching on these closely adjacent space vector points highly suppresses the harmonic ripple content in the phase voltage. At the same time, because of the dodecagonal space vector structure, all the 6n±1 (n=odd) harmonics are eliminated from the phase voltage. A nearly sinusoidal phase voltage can be generated without resorting to high frequency switching of the inverters. Moreover, a regular dodecagon is closer to a circle than a regular hexagon, thus in the present scheme the linear modulation gets extended by 6.6% compared to hexagonal space vector structure. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

55 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Inverter and switch ratings Here, ‘m´ is defined as the modulation index, which under constant V/f ratio, is equal to 1 at 50Hz rated frequency operation. In conventional hexagonal space vector structure, if the dc link voltage magnitude is VD, then the maximum fundamental voltage available is 0.637VD at m=1; whereas in linear modulation range, the maximum fundamental voltage obtained is 0.577VD at m=0.906. For comparison purpose, in the present space vector structure, the maximum fundamental voltage obtained is made equal to 0.637VD at m=1, then the value of k is set to However, the advantage in this case is the extension of the linear modulation range, since the maximum fundamental voltage obtained in linear modulation is 0.615VD obtained at m=0.966 corresponding to 48.3 Hz operation. It is thus possible, at low switching frequency, for a smooth transition of the motor speed into over-modulation region and 12-step mode (m=1) without any special compensation schemes. Using k=0.789, the device ratings of INV1 and INV2 are found to be 0.395VD and 0.144VD respectively. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

56 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
PWM timing calculations PWM timing calculations are done separately for type-1 and type-2 dodecagons. Later they are used to find a uniform timing relation. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA [movie]

57 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
PWM timing calculations type-2 polygon V2, T2 Instead of switching points V1 and V2, the same reference vector VR can be realized by switching V3 and V4, but with different time durations. This will reduce the instantaneous error between the reference vector and the switching vectors, causing multilevel operation of the inverter. V4, T’2 V3, T’1 V1, T1 Note: k’ =V3/ V1=V2/ V4 is a fraction. T1+T2+T0= T’1+T’2+ T’0=TS. Point Switched for V1 T1 V2 T2 O T0 Point Switched for V3(=k’ V1) T’1=T1/k’ V4(=k’ V2) T’2=T2/k’ O T’0 provided T0’ ≥ 0 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

58 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
PWM timing calculations type-2 polygon V2, T2 V4, T’2 V1, T1 V3, T’1 The same relation can be extended to the type-2 polygon. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

59 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
PWM timing calculations for both types of polygons Points O,K and J are from type-1 polygon, while point F is on type-2 polygon. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

60 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
PWM timing calculations for both types of polygons T2 r4 r5 T0 T1 Point Switched for O T0 K T1 J T2 Point Switched for F T’0 = T0 / (1-k1) K T’1=T1- T’0 . k1/2 J T’2=T2- T’0 . k1/2 T1+T2+T0= T’1+T’2+ T’0=TS. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

61 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
PWM timing calculations for both types of polygons r4 r5 By switching F, K and J (blue) one gets, (Point K) (Point J) (Point F) Where, CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

62 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
PWM timing calculations for both types of polygons r4 r5 Equating the real and imaginary parts of previous two equations, (Point F) (Point K) (Point J) where, CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

63 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental verification A 3.7kW induction motor was fed by the proposed inverter under experimental condition, operating under open loop constant V/f control at no load. The motor was made to run under no load in order to show the effect of changing PWM patterns of the generated voltage on the motor current. In order to limit the switching frequency of the inverter, number of samples is decided as follow: Upto 10 Hz operation: 8 samples per sector. 10 Hz-30 Hz: 4 samples per sector. 30Hz-12step operation: 2 samples per sector leading to final 12-step mode. The samples are always taken synchronized with the start of the sector. A digital signal processor (DSP), TMS320LF2812 is used for experimental verification. The DSP is used for calculating the PWM timing durations. The actual gating signals to drive all the devices are generated using a SPARTAN XC3S200 FPGA. The FPGA stores the look-up table for the switching state combination of both the inverters for a particular space vector point. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

64 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-10 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current Switching happens within the innermost dodecagonal space vectors. Here, the number of samples per sector is taken as 8, as such the voltage and current harmonics reside around (12x8=) 96 times the fundamental. Individual devices of INV1 and INV2 are respectively switched at (10x16=) 160 Hz and (10x48=) 480 Hz. INV1 is switched only 1/3rd of a cycle, thereby the switching loss is less. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

65 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-20 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current Switching happens within the first and second dodecagonal space vectors. 4 samples are taken in a sector, so the first band of carrier harmonics reside around 48 times the fundamental. Because of the multilevel structure, all the harmonics are highly suppressed. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

66 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Operation at 24.5 Hz CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

67 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-24.5 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current Here the reference vector passes through the boundary of E dodecagon. As such, switching happens sometimes among points on the ‘D’ and ‘E’ dodecagons, while at other times among ‘E’ and ‘F’ dodecagons. The high voltage inverter switches about 20% of the cycle, thus the switching losses are minimized. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

68 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-46 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current Two samples per sector are taken here. The phase voltage waveform of phase A distinctly shows the presence of 20 steps in a cycle, although 24 vectors are switched altogether. The phase voltage harmonics reside at (24x45=) 1080 Hz, while individual devices of INV1 and INV2 switch at (5x45=) 225 Hz and (15x 45=) 675 Hz. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

69 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
20-steps in phase voltage at Operation at 46 Hz Vectors numbered 37, 48, 50 and 60 switched at the positive peak of the phase-A waveform have same projection on A-phase axis. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

70 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-49.9 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current The phase voltage waveform of phase A shows the 20 steps in a cycle. The switching vectors involved are located on the vertices of the A and B dodecagons, because of very small zero periods in a cycle. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

71 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
20-steps in phase voltage at 49.9 Hz Vectors numbered 49, 61 and 72 switched at the positive peak of the phase-A waveform have same projection on A-phase axis. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

72 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Experimental results-50 Hz operation Normalized harmonic spectrum of Phase voltage Phase voltage Pole voltage- high voltage inverter Phase current Pole voltage-low voltage inverter Phase current This is the 12-step operation of the inverter, when maximum fundamental voltage is available. Under this condition, INV1 and INV2 are switched 3 and 12 times respectively in a cycle. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

73 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Input current drawn from the grid Motor phase voltage Normalized harmonic spectrum of Motor phase current input current Grid side voltage input current Because of the presence of the star-delta transformer at the input that forms the dc bus ratio, the input current is more sinusoidal than what is observed in a single transformer supplying an uncontrolled rectifier CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

74 Motor acceleration with open loop V/f Control
Phase voltage Phase current Transition of motor phase voltage and current from 20 Hz to 30Hz Transition of motor phase voltage and current from over-modulation to 12-step operation. In the first case, the reference vector starts from inside dodecagon E, crosses through the boundary of it and finally settles below the D dodecagon. In the second case, the number of samples per sector is changed from 2 to 1 at 12-step operation. Correct calculation of the PWM timings and complete elimination of the 5th and 7th order harmonics ensure that the motor current changes smoothly during the transition. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

75 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Comparison with a 5-level space vector diagram Phase voltage THD Phase voltage WTHD Phase current THD Phase Current WTHD unit % 20 Hz 5-level Inv 28.76 0.68 10.73 0.54 Proposed Inv 22.26 0.51 8.53 0.42 24.5 Hz 19.78 9.85 0.52 16.24 7.14 0.43 46 Hz 19.91 0.77 16.05 0.89 15.69 0.57 12.62 0.62 49.9 Hz 15.3 1.31 18.8 3.07 7.26 0.28 4.68 0.24 50 Hz 30.54 4.64 52.47 9.55 17.54 1.04 19.54 1.5 The harmonic distortion is less in the proposed scheme. This is more prominent in the higher modulation indices where the number of samples per sector is less, thus the switching frequency harmonics containing 5th and 7th order harmonics in the 5-level scheme come closer to the fundamental. Because of the total elimination of the these harmonics from the phase voltage in the present case, the ripple content in the phase voltage will be less. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

76 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Harmonic performance in terms of flux ripple The rms value of the flux ripple is calculated and plotted above under constant V/f ratio and 24 samples in a fundamental period. It shows that for most of the operating conditions, the flux ripple is around 1% of the fundamental flux impressed on the machine, and thus restricts the torque ripple in the machine. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

77 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Synopsis A new space vector diagram for induction motor drive is proposed, which divides the space vector plane into six concentric dodecagons. Here the space vector diagram is characterized by alternately placed type-1 and type-2 dodecagons which become closer to each other at higher radii. As such the harmonics in the phase voltage are reduced. Apart from this, the known benefits of dodecagonal space vector diagram like the complete elimination of all 6n±1 harmonics, (n=odd) from phase voltage and the extension of linear modulation range, are also retained here. The high voltage inverter having a voltage of about 3 times the lower one, is switched almost 1/3rd compared to the low voltage inverter. A comparison with 5-level inverter topology is also given which shows that the present scheme produces less harmonic distortion in the phase voltage. Because of the use of star-delta transformers for having the dc bus in the ratio 1:0.366, the input current has lesser harmonics compared to the case when a single transformer supplies the inverter. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

78 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Conclusion Different dodecagonal space vector diagrams are proposed in this work. In one of the schemes, the space vector diagram consists of two concentric dodecagons, with the radius of the outer one twice the inner one. This has the benefit of reducing the device rating and dv/dt stress on the devices. This is then further refined to distribute six dodecagons in the space vector diagram. Switching on these closely spaced dodecagons will highly reduce the harmonic content in the phase voltage, apart from totally eliminating all the 5th and 7th order harmonics from the phase voltage. In another work, a 4-level inverter with asymmetric dc links is used to generate hexagonal space vector diagrams at lower modulation indices and a dodecagonal space vector structure at higher modulation index finally leading to 12-step operation of the inverter. This structure thus, incorporates the advantages of both hexagonal and dodecagonal space vector diagrams. With increased linear modulation range, less switching frequency and improved harmonic spectrum, the proposed concepts may be considered as an interesting addition to the field of multilevel inverters for high/medium voltage high power applications. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA

79 CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA
Papers out of this work Anandarup Das, K. Sivakumar, Rijil Ramchand, Chintan Patel and K. Gopakumar, "A Combination of Hexagonal and 12-sided Polygonal Voltage Space Vector PWM control for IM Drives Using Cascaded Two Level Inverters", IEEE Trans. On Industrial Electronics, vol. 56, no. 5, May 2009, pp Anandarup Das, K. Sivakumar, Rijil Ramchand, Chintan Patel and K. Gopakumar, "A Pulse Width Modulated Control of Induction Motor Drive Using Multilevel 12- sided Polygonal Voltage Space Vectors", IEEE Trans. on Industrial Electronics, vol. 56, no. 7, July 2009, pp Anandarup Das, K. Sivakumar, Rijil Ramchand, Chintan Patel and K. Gopakumar, "A High Resolution Pulse Width Modulation Technique Using Concentric Multilevel Dodecagonal Voltage Space Vector Structures", Proc. of ISIE 2009, Jul (Best paper award in the conference). Anandarup Das, K. Sivakumar, Rijil Ramchand, Chintan Patel and K. Gopakumar, "Multilevel Dodecagonal Space Vector Generation for Open-end Winding Induction Motor Drive Using Conventional Three Level Inverters", Proc. of EPE 2009, Sep 2009, pp 1-8. Anandarup Das, K. Sivakumar, Gopal Mondal and K. Gopakumar, "A Multilevel Inverter with Hexagonal and 12-sided Polygonal Space Vector Structure for Induction Motor Drive", Proc. of IECON 2008, Nov 2008, pp Anandarup Das and K. Gopakumar "A Voltage Space Vector Diagram Formed By Six Concentric Dodecagons for Induction Motor Drives", communicated to IEEE Trans. on Power Electronics. CEDT, INDIAN INSTITUTE OF SCIENCE, BANGALORE, INDIA