1 Development and Preliminary Application of Image Filters for Quantitative XCT Damage Analyses Orlando, Florida, USA March 10 - 14, 2003 12 th Annual Research Symposium of the American Society for Nondestructive Testing

2 Outline Abstract TIFF Binaries 3D Reconstructions Creating Image Filters Using AutoCAD layers as image filters Interpreting Data Summary

3 Abstract Segmented binarized XCT images were analyzed using a method developed using a number of software applications to graphically interrogate the physical amount of ballistic meso-damage (>250  m) in impacted titanium alloy (Ti-6Al-4V) disk samples.

4 TIFF image Binaries A threshold is used to create the binary TIFF images –These images are exported as a stack of binary 16 bit TIFF images!

5 3D Reconstructions 16 Bit Tiff Images –ACTIS software puts these together and makes a 3D solid –Analysis of images using the ACTIS software produces qualitative results

6 Using AutoCAD, a filter was developed –First: A cylinder is created within another cylinder with radius plus ¼ millimeter

7 –Second The smaller cylinder is subtracted from the larger one, creating a ring

8 –Third The ¼ millimeter ring is subtracted from a rectangular solid, creating a hollow rectangular solid

9 –Finally Hollow rectangular solids are created from subtracting rings with three to twenty millimeter radii and each one becomes an individual layer within AutoCAD Combined Layers

10 TIFF Image is 70 X 70; it is aligned within the Tiff Image Bounding Box Layer Bounding Box – 100mm X 100mm X 1mmTIFF Image Bounding Box – 70mm X 70mm Using AutoCAD Layers as Image Filters

11 TIFF Image Stays in Original Position (0.334, 1.476) Layers move to a calculated offset.

12 TIFF image is placed on alignment lines which lie beneath the hollow rectangular solid

13 The current ring is zoomed in on

14 The Scene is Rendered, creating a ring with a ¼ millimeter radius. –This shows damaged and undamaged pixels –The rendered scene is then exported as a Bitmap image

15 For all ¼ millimeter layers, this process is executed

16 Using The Exported Images The exported bitmap images created in AutoCAD are multiple colors; the solids color is magenta, the damaged pixels are black, and the undamaged pixels are white AutoCAD averages the color of the pixels from the inner and outer radial ring causing more than three colors to be present in the export Exported images from AutoCAD are imported to Paint Shop Pro and reduced to three colors

17 ImageJ and the Excel Standard Table Using Image J, the three color images made with Paint Shop Pro are analyzed and the number of pixels for each color are reported. An excel table calculates values for Axi- Symmetric Damage Fraction, Cumulative Damage, and Cumulative Unit Damage.

18 Axi-Symmetric Damage Fraction A measure of the percent damage in each quarter millimeter ring out to the edge of the object. %d

19 Axi-Symmetric Unit Damage Fraction 2030405060

20 Summary The data from this work and work to come will allow more accurate damage modeling to take place Predicting failure in materials is essential in improving the survivability and lethality of military units

21 Current Goals Submit 2 Abstracts to NDIA conference ’24 th International Symposium on Ballistics’ –Abstracts Due - December 1, 2007 –Paper Selection - January 15, 2008 –Authors Notified - February 15, 2008 –Papers Due - April 1, 2008 –Final Program - June 1, 2008 –Symposium - September 22-26, 2008

22 Abstract 1 Perspectives on the Requirements, Development, and Outputs of an X-Ray Computed Tomography Image Processing Application for Ballistic Impact Analysis In Armor Samples