Global Security
2
No Dead detecting Space Radiation Source Boom Drive Container Detectors
3
SCAN-II /1Dual-view Fixed-Large Industrial Inspection Equipment
4
SCAN-II-2/3 Dual-view Large Industrial Inspection Equipment
5
AB SCAN-II/1 Dual-view Large Industrial Inspection Equipment A. Detectors A B. Detectors B
6
SCAN-VI /1 Single-view Mobile Inspection Equipment
7
TV Monitoring System Control Lights Panel Drive Control PC Image Acquisition Control PC Control Console 1234 12 3 4
8
1.2¬1.5m (4.92ft) Shielding Wall Office 0.08μGy/hr Test Point Radiation test
9
16m (52t) 28m (92ft) +0.00 4.2m (13.78ft) 4.8m (15.75ft) EntranceExit Dimensions: L 28 x W 16 x H 4.8 mt. Office floor Scanning tunnel
10
24m (78.72ft) 5.6m (18.36ft) Possible Layout of Office Building Ground Level for Scan I Clearance Manual Inspection Check-in Entrance Exit Guard Stairs
11
24m (78.72ft) 5.6m (18.36ft) Office Control Room Inspection Stations Office Stairs Possible Layout of Office Building Upper Floor for -SCAN-I
12
Detector Module (DM) (32 Channels Each) 32 DM in Detector Arc Detector Arc
13
TypeScan-IScan-II-1/2/3Scan-V-1/2/3Scan-VI-1/2Scan--IV-2/4/6 Scanning ways FixedFixedRe-locatableMobile Air Cargo Scan area ( wide×long) 10m×28m 10m×32m/36m/ 36m 18m×28m/30m IV-2: 8m×12m IV-2: 8m×12m IV-4/6: 8m×15m Source Activity Co-60 500Ci Co-60 100Ci Co-60 300Ci Number of Detecting Units 10241088(A)1024(B) V-1: 1024 V-1: 1024 V-2/3: 1088(A) V-2/3: 1088(A) 1024(B) 1024(B) VI-1: 896 VI-1: 896 VI-2: 896 (A) VI-2: 896 (A) 832(B) 832(B) IV-2: 928 IV-4: 992(A) 928(B) IV-6: 1024(A) 928(B) Image Size 1024×4096 1088×4096 1088×4096 1024×4096 1024×4096 V-1: 1024×4096 V-1: 1024×4096 V- 2/3:1088×4096(A) V- 2/3:1088×4096(A) 1024×4096(B) 1024×4096(B) VI-1: 896×4096 VI-2: 896×4096(A) VI-2: 896×4096(A) 832×4096(B) 832×4096(B) IV-2: 928×4096 IV-4: 992×4096(A) 928×4096(B) 928×4096(B) IV-6: 1024×4096(A) 928×4096(B) 928×4096(B) Steel Penetration ≥180~220mm≥180~220mm≥180~220mm≥160~180mm≥180~200mm Resolution (without blocking) ≤0.6 ¬ 0.8mm ≤0.6~0.8mm≤0.6~0.8mm≤1.0~1.2mm≤0.8~1.0mm Resolution (behind 100mm steel block) ≤2.0~2.5mm≤2.0~2.5mm≤2.0~2.5mm≤3.0~3.5mm≤2.5~3.0mm Spatial Resolution < 6mm Throughput ≥ 30sets/hr 10~20sets/hr ≤ 60ULD/hr Scanning Size 4m×4.6m×18m wide×high×long wide×high×long wide×high×long 3m×4.6m ×18m wide×high×long3.18m×3.18mwide×high Power Consumption ≤ 20kw ≤ 30kw ≤20kw≤20kw CharactersSingle-view Dual-view ( 30°/90° ) Single/Dual-view ( 30°/90° ) Continuous Scanning Single/Dual-view ( 30° ) Continuous Scanning Single/Dual-view ( 30°/90° ) Continuous Scanning Technical Specifications of Gamma Ray scanners
14
Unsharpened Image Sharpened Image
15
T.V. Displays Concealed in Mobile Phone Parts
16
Picture Kerosene Inflammable Explosives WaterBeer Beer4 180 Beer4 180 Beer3 Water1 177 Beer3 Inflammable1 170 Beer3 Exp.1 166 Beer3 Kerosene1 192 Flammables Concealed in Bottles Density Image
17
Multi-Angle Images : Flank ( 90 Angle )