Project number: 2011-1-DE3-COM06-19211 6. Type of home : bungalow Usable floor area : 24,20 m² Rate of energy demand for heating : 14 kWh/m².

Similar presentations


Presentation on theme: "Project number: 2011-1-DE3-COM06-19211 6. Type of home : bungalow Usable floor area : 24,20 m² Rate of energy demand for heating : 14 kWh/m²."— Presentation transcript:

1 project number: 2011-1-DE3-COM06-19211 6

2 Type of home : bungalow Usable floor area : 24,20 m² Rate of energy demand for heating : 14 kWh/m²

3

4  Living room - 10,00 m²  Kitchen and hall - 11,78 m²  Toilet - 2,42 m²

5 In Poland, the cheapest method of obtaining a relatively large amount of energy for the house Requirements for small wind turbine: 12 m mast or tower within the existing building no obstacles to the west (the most frequent winds in Poland)

6 diameter rotor4 m 3 blades the wind that runs< 1m/s loading1.5/3 m/s m/s 3kW9m/s maximum power12-16 m/s nominal power3 kW maximum power9 kW temperature range - 40 to +60C generator: Self excitation generator 3xAC the output curent48VDC Nominal EnerWin 3002

7 EnerWin3002 full set:  inverter 3 kW (full sine)  600A charge controller with solar controller for 500 W  cascade controller heaters up to 15kW  fast, aerodynamic blades with a span of 4 m  10 pieces of identical maintenance - free battery  survival mechanism of strong winds (up to 200km/h)  maintenance – free rotator (the cable does not turn inside the mast !)

8 location of the home Realistically, you can get 400 – 700 KWh/m 2 It gives you coverage of needs for:  hot water – 60 – 80%  central heating – 10 – 20 % Daily sunlight of 1 m 2 surfice with a slope of 45° Month Solar radiation kWh/m 2 I0,6 II1,0 III3,0 IV3,8 V4,8 VI5,4 VII5,3 VIII4,9 IX3,3 X1,7 XI0,7 XII0,5

9 length: 2020 mm width: 1035 mm height: 90 mm the gross of the collector surface area: 2,091 m 2 active surface: 1,827 m 2 liquid capacity: 1,1 l weight: 36 kg optical efficiency: 81,7 % loss factor A1: 4,17 W/(m 2 K) loss factor A2: 0,0077 W/(m 2 K 2 ) HEWALEX 2SLP-200W

10  solar collector KS2000 SLP: 2 pc  connection set for the collector ZPKS 2  flexible connection KS ¾”  cover profile KSL  heater VF200-2  pump control unit ZPS 6-01  a set of expansion vessel ZNP 18DS  heater connection kit PW  fluid Termsol EKO -25 o C: 20 kg  liquid hand pump for fill the installation HEWALEX 2SLP-200W – full set

11 Vikersønn Bjørn 5  height : 1372 mm  width : 602 mm  depth : 607 mm  power : 380/420V - 3~ - 50 Hz  refrigerant : R407C  power consumption : 1,15 kW  heat output : 5,03 kW  coefficient of performance COP: 4,38

12 Vikersønn Bjørn 5 in our climate piping with the liquid in a closed circuit is placed on the 2m depth where temperatures never drops below 5 0 C obtaining 1kW of energy requires receiving of heat from the surface 25 – 50 m 2

13

14 EkoZefir Rk-150-SP  capacity: 150 m³/h  heat recovery rate: 68-84%  external static pressure: 66 Pa  pover consumption (max): 48W  width: 500 mm  height: 260 mm  depth: 500 mm  stub pipes dimensions: Ø 125 mm  insulation thickness: 30 mm  weight without package: 16 kg  pover supply: 230 V/50 Hz  job position: horizontal

15 Ventilation must be designed so that it draws a minimum of: from the kitchen from 30 do 70 m 3 /h (depending on whether the kitchen with a window, the number of people, kind of stove), from the bathroom 50 m 3 /h, from a separate toilet 30 m 3 /h, from a room without windows (eg. dressing room) 15 m 3 /h, from living rooms (in some specific situationns) 30 m 3 /h.

16


Download ppt "Project number: 2011-1-DE3-COM06-19211 6. Type of home : bungalow Usable floor area : 24,20 m² Rate of energy demand for heating : 14 kWh/m²."