1

2 Electro Electric Systems Hyundai Inverter 1 Electro Electric Systems >> N50 Inverter (200V class, single phase)

3 Electro Electric Systems Hyundai Inverter 2 Contents 1.N50 Dimension 2.N50 Input/Output Terminal 3.N50 Specifications 4.N50 Characteristics 5.N50 Control Terminal Functions 6.Performance Comparison 7.N50 Block Diagram

4 Electro Electric Systems Hyundai Inverter 3 1. N50 Dimension TypeN50N100plus Rating 0.75kW 80 × 142 ×135 (100%)105 × 130 ×135 (120%) 1.5kW & 2.2kW 95 × 142 ×135 (100%)105 × 130 ×155 (116%) 15% downsize against N100 [ Minimize the Width for Easy Installation]

5 Electro Electric Systems Hyundai Inverter 4 Motor Connection Power Connection (Single Phase 200V class) Regenerative Brake V I Analog Voltage/Current Choice RS485 RS485 Communication Port 2. N50 Input/Output Terminal

6 Electro Electric Systems Hyundai Inverter 5 ModelN50-007SFN50-015SFN50-022SF Applicable Motor (kW) 0.75kW1.5kW2.2kW Rated Output Current (A) 5711 Rated Capacity(kVA) 1.6kVA2.7kVA3.5kVA Rated Input Voltage(V) 1-Phase, 200 ~ 230V±10%, 50/60Hz±5% Rated Output Voltage(V) 3-Phase 200~230V (Corresponding to input voltage) Control Method Space Vector PWM Control Starting Torque About 200% (Sensorless Vector Control Only) Output Freq. Range 0.5Hz ~ 400Hz Sales Points Adoption of sensorless vector control : Powerful torque for micro inverter [Mitsubish and Delta V/F Control] Solve the Vibration and noise problems at low speed : By applying CT at the output, the control performance at low speed is improved. Solve the Torque Drop at high speed operation by complementing the current stall function. Reinforcement of External Noise Immunity during the communication : Common Grounding Design of Controller, Power Division and Case) Repression of FAN noise at rest by operating the fan after operation instruction 3. N50 Specifications

7 Electro Electric Systems Hyundai Inverter 6 (1)Supply Power for Treadmill Controller Washing Machine - Standard : 5V, 300mA max - Option : 5V, 1000mA max 4. N50 Characteristics (2) Choice between Communication and Analog: RS485 Communication(Option Board) Option(5V,1A) Option Board

8 Electro Electric Systems Hyundai Inverter 7 4. N50 Characteristics (3) Cooling FAN starts only after operation instruction. (4) DISPLAY and Operating Part Built-in (5) Expansion of Input/Output Terminals (General Purpose) Energy Saving Reduction of FAN Noise Easy operation and monitoring Applicable to Treadmill, Washing Machine, Fan BLOWER

9 Electro Electric Systems Hyundai Inverter 8 Signal Term Symbol Terminal NameTerminal Functions Input Signal 5 Intelligent Input Terminal FW, RV, CF1~4, JG, 2CH FRS, EXT, SFT, USP, RS Contact Input: Close :ON(Operating) Open : OFF(Stop) Minimum On Time:12ms or more 4 3 2 1 CM1 Common Terminal for Input and Frequency Command Freq. Command HFrequency Command PowerDC 10V or 5V O/OI Frequency Voltage/Current Frequency Command Terminal 0~10VDC / 4~20mA CM1 Common Terminal for Input and Frequency Command Monitor SignalFMFrequency Monitor Terminal Output Signal 11 Intelligent Output Terminal RUN, FA1, FA2, OL, OD, AL 27VDC, 50mA max CM2Common Terminal for Output Signal 5. N50 Control Terminal Functions

10 Electro Electric Systems Hyundai Inverter 9 6. Performance Comparison

11 Electro Electric Systems Hyundai Inverter 10 7. N50 Block Diagram Improved reliability due to current sensing using CT and High Speed Precision Control using DSP Device Input/Output Signal External Contact Signal (Analog) Communication Signal RS 485


Download ppt "Electro Electric Systems Hyundai Inverter 1 Electro Electric Systems >> N50 Inverter (200V class, single phase)"