Index Sr No. Description Slide no. 1
PCB of D/Z panel & KENSTAR/ELECTROLUX panel 2 PCB of Hot & Cold type & Left-Right swing 3 PCB of Air series panel & WiFi 4 PCB component identification sheet 5 Error Codes 6-9 6 PCB diagnosis in the field 10 7 PCB check process while removing for replacement 11-12 8 How to run AC in worst condition 13 9 Care in field for sending defective PCB 14
2
India dance series Cooling/D panel/Z panel
PCB Identification Code-0x1E3746 Software Version code-24 Cooling/KENSTAR panel/ELECTROLUX panel PCB Identification Code-0x1CEED1 Software Version code-10 18k ControlPCB Part Code- Model Code-07 12k Control PCB Model Code-05 Display PCB Part Code
3
India dance series Cooling & Heating/D panel/Z panel
PCB Identification Code-0x1E6C3A Software Version code-23 Cooling/Left –Right swing/D panel/Z panel PCB Identification Code-0x1DF999 Software Version code-21 18k ControlPCB Part Code- Model Code-08 Model Code-07 12k Control PCB Model Code-06 Model Code-05 Display PCB Part Code
4
AIR series Cooling PCB PCB Identification Code-0x1E3746
Software Version code-24 Cooling/WiFi PCB Identification Code-0x277013 Software Version code-10 18k ControlPCB Part Code Model Code-03 Part Code 12k Control PCB Part Code Model Code-01 Part Code Display PCB Part Code WiFi CHIP
5
PCB Component Identification Sheet
6
ERROR CODE-E1,E2 ERROR CODE-E1 CAUSES COUNTERMEASURES PICTURE
ROOM SENSOR NOT PROPERLY INSERTED AT CN5 CONNECTOR LOCATION INSERT ROOM SENSOR PROPERLY AT CN5 CONNECTOR LOCATION ROOM SENSOR FAULTY REPLACE ROOM SENSOR WITH NEW ONE ROOM SENSOR CN5 ERROR CODE-E2 CAUSES COUNTERMEASURES PICTURE COIL SENSOR NOT PROPERLY INSERTED AT CN6 CONNECTOR LOCATION INSERT COIL SENSOR PROPERLY AT CN6 CONNECTOR LOCATION COIL SENSOR FAULTY REPLACE COIL SENSOR WITH NEW ONE COIL SENSOR CN6
7
1.LOW GAS CAUSING FROSTING
ERROR CODE-E4 CAUSES COUNTERMEASURES 1.LOW GAS CAUSING FROSTING INSERT GAS 2.EVAPORATOR COIL DIRTY REMOVE FROSTING 3.TEMPERATURE CONTROL Under cooling and dry modes if Te≤-2⁰C for consecutive 3min and the compressor continuously runs for 5 min or longer, the compressor will stop running while the indoor fan continues to blow in the set fan speed ;if Te≥7⁰C, the protection will be suspended IT MAY BE BECAUSE OF EVAPORATING COIL SUCTION IS BLOCKED SO REMOVE BLOCKAGE OVER OF IT. 4.COMPRESSOR PROTECTION If the following 3 conditions have been met for 1 hour and 45 min, the compressor will stop running for 7 min while the fan keeps running at set fan speed. A)Compressor runs continuously b)Indoor fan runs at low medium or ultra low fan speed c)In case of room Tr<26⁰C,If compressor stops , the timing process starts again. Note: If the fan runs at other speeds or room temp≥26⁰C,the timing will be suspended; the timing process will continue if those conditions are met again; and the cumulative time will be cleared in case of shutdown or mode conversion. NO NEED TO WORRY
8
ERROR CODE-E5 CAUSES COUNTERMEASURES PICTURE
1.MOTOR CONNECTORS ARE NOT PROPERLY INSERTED AT LOCATION CN8 & CN4 INSERT CONNETORS PROPERLY AT CN8 & CN4 LOCATION 2.INDOOR FAN MOTOR FAULTY REPLACE INDOOR FAN MOTOR WITH NEW ONE 3.INDOOR FAN MOTOR JAM 4.BLOWER JAM UNBLOCK THE BLOWER 5.SHAFT OUT OF BEARING INSERT SHAFT PROPERLY IN BEARING CN8 & CN4 LOCATION IDU FAN MOTOR PROPER MOTOR-BLOWER ASSY.
9
ERROR CODE-E6 CFC-free protection(E6)
This function is applicable for cool mode. After the compressor runs for consecutive 15min, if the difference between evaporator temperature(Te) and room temperature (Tr) exceeds range C(means Te>Tr-3℃) and lasts for 1min, the indoor fan will run at low speed (the display is keeping unchanged). 1min later, if the difference is still beyond range C(means Te>Tr-3℃), it will be judged that the refrigeration capacity of AC is lack, so the entire machine will be stopped and the indoor panel of AC will display fault code(E6). (Range C: Te ≤ Tr - 3℃) CFC-free protection will be tested only once after startup, the machine cannot be restored in case of CFC-free protection and must be repowered." Following may be reasons for lacking refrigeration capacity CAUSES COUNTERMEASURES PICTURE 1.VERY LOW GAS FILL THE GAS IN THE UNIT 2.GAS LEAKAGE FIND LEAKAGE POINT AND THEN MAKE ARRANGEMENT FOR NO LEAKAGE AND THEN FILL THE GAS IN THE UNIT 3.COIL SENSOR NOT PROPERLY INSERTED AT EVAPORATING COIL HOLDER LOCATION INSERT COIL SENSOR PROPERLY IN COIL SENSOR HOLDER 4. COMPRESSOR NOT GETTING ON CHECK COMPRESSOR RELAY TO CONNECTOR WIRE PROPERLY LOCKED IF NOT THEN PROPERLY LOCK IT. 5.COMPRESSOR GETTING HIGH CURRENT CHECK WIRING OF COMPRESSOR TO CAPACITOR IF WRONG THEN CORRET IT. 6.COMPRESSOR FAULTY REPLACE COMPRESSOR WITH NEW ONE 7.CAPILLARY BLOCK REPLACE CAPILLARY WITH NEW ONE 8.CONDENSER COIL BLOCK REPLACE CONDENSER COIL WITH NEW ONE 9.OUTDOOR FAN MOTOR FAULTY REPLACE OUTDOOR FAN MOTOR WITH NEW ONE PROPER FITMENT OF COIL SENSOR PROPER CONNECTION OF COMP.RELAY TO CONNECTOR COIL CAPILLARY COMPRESSOR ODU MOTOR
10
PCB diagnosis in the field
Self-inspection function 1. This function is used to test whether all input and output items on the main control PCB and the display PCB are normal. 2.Press the emergency button to supply power, a buzzer sounds once after 0.5 seconds and then it enters into the self-inspection mode: The self-inspection mode operates as follows: →Each phase of the stepper motor acts for 0.5S → air door swinging opens → PG motor (high speed air) runs for 1S → the outdoor fan runs for 1S → the compressor runs for 1S → the four-way valve runs for 1S → air door swinging closes → the buzzer sounds short beep; →7 segment and 6 indicator led’s glows for 1S → the room temperature shows for 1s(On 0.5 s, Off 0.5 s) → the coil temperature displays for 1s → software version number shows for 1s → model code shows 0.5s → the 7 segment displays in order “00”“11”“22”“33”“44”“55”“66”“77”“88”“99” for 0.5s respectively → the following led’s are glows for 0.5 respectively: °C led / Cool mode led / Heat mode led/Dry mode led / Fan mode led / Timer led / Turbo led . 3. In the process of self-inspection, if a fault occurs, it will report the fault and stop the self-inspection; in case of no fault, the driving signals in two columns will be output in cycle and it will stop after 5 cycles.
11
PCB check process before removing for replacement
a)Control PCB checking 1.Check all components are intact on control PCB as shown in picture ,if not then connect it 2.Check tracks of the PCB is broken or burnt 3.Check if any component is burnt or blown 4.Check power supply in coming in fuse /transformer area 5.Check relay for compressor & fan motor getting hot or chattering 6.Check for transformer T1-getting hot or any winding broken 7.Check capacitor, transformer, elico, mov, is burnt or dislocated 8.Check programming pins of CN2 connector should not touch each other, If touching then separate them apart 9.Check F1 fuse is properly fitted ,if not then properly fit it, it should touch fuse holder properly Programming pins Properly fitment of fuse
12
PCB check process before removing for replacement
b)Display PCB checking 1.If any of the led of display not glowing then check any wire cut of connector, if cut then connect it 2. If 7 segment or other led’s not glowing properly, then check i)whether there is soldering short on display connector CN9 ,if present then remove that shorting ii)Check whether any soldering short in IC1 IC is there, if present then remove it CN9 display connector IC1
13
How to run AC in worst condition
If compressor works in good condition you can run AC for half an hour by commissioning mode Commissioning: press the emergency button and hold it for 5s until the buzzer beeps twice, then the controller will enter commissioning mode. Press down and hold the button for another 5s, commissioning will be stopped. The commissioning lasts 30min, and the cooling mode icon will start blinking a. During commissioning, the determination conditions for room temperature sensor will become ineffective, the compressor will start normally after 3 minutes of protection (no 3min protection if initially powered), the indoor fan will blow at high speed, the machine will work in cooling mode, and vertical swing angle will set to angle 3. b. No anti-freeze or over temperature protection during commissioning. c. Press and hold emergency button for 5s, then the commissioning will be stopped. d. The 7 segment displays (Tr) room temperature during commissioning, If the emergency button is pressed once while it is showing room Temp, the 7 segment will display (Te)coil temp. ,and press again to show room temp(Tr) e. Auto Clean Function do not run under commissioning condition
14
Care in field for sending defective PCB
1.Make inspection sheet ,mention model no., serial no. of PCB in addition to other component data like Customer name, complaint no. etc. 2Defective component area to be marked in PCB 3.Proper packing with foam poly bag/ bubble bag & carton to be used for sending factory analysis 4. If PCB not marked or not properly packed then factory cannot inspect that PCB properly. Proper packing of PCB