Presentation is loading. Please wait.

Presentation is loading. Please wait.

GS2060/TL260GS Product Technical Training

Similar presentations


Presentation on theme: "GS2060/TL260GS Product Technical Training"— Presentation transcript:

1 GS2060/TL260GS Product Technical Training
2-Way Wireless Security Suite

2 GS2060/TL260GS – Product Overview
2-Way Wireless Security Suite

3 2-Way Wireless Security Suite
GS2060 GS2060 GSM/GPRS Wireless Alarm Communicator Overview: The GS2065 provides primary or backup GSM/GPRS communication for Power Series PC1864/1832/1616 control panels Specifications: Dimensions : 3.937"x5.875"x0.625" (100mmx150mmx15mm) Weight : 310 g Antenna Gain : 2db Input Voltage : 11.1 to 12.6 V (from the Panel Bell output) Current Draw : 65 mA at 12V (400 mA during the GSM transmission) Operating Environment : 5 º C to 40º C (40º F to 104º F) READ SCREEN PASS MODULE AROUND 2-Way Wireless Security Suite

4 2-Way Wireless Security Suite
GS2060 GS2060 GSM/GPRS Wireless Alarm Communicator Features: Back up and primary GSM/GPRS alarm communication Panel remote uploading/downloading support via GSM/GPRS Individual Periodic Test Transmission via GSM/GPRS Supervision heartbeats via GSM/GPRS 128-bit AES encryption over GSM/GPRS Full event reporting SIA format PC-Link connection SIM card included Signal strength and trouble display Activating and initializing through Connect 24 Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz READ SCREEN 2-Way Wireless Security Suite

5 2-Way Wireless Security Suite
GS2060 GS2060 GSM/GPRS Wireless Alarm Communicator Compatible Control Panel & Cabinet Control panel: Power Series PC1864/1832/1616 version 4.1 and higher Cabinet: PC5003C and PC4050C Compatible Receivers: Sur-Gard System I Receiver: version 1.10 and higher Sur-Gard System II Receiver: version 2.00 and higher Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver) Product Model and Accessories: GS2060GS-USA: For US market with AT&T SIM card GS2060GS-CDN: For Canada market with Roger SIM card GS-15ANTQ: Antenna Extension Kits with 15 feet cable GS-25ANTQ: Antenna Extension Kits with 25 feet cable GS-50ANTQ: Antenna Extension Kits with 50 feet cable READ SCREEN 2-Way Wireless Security Suite

6 2-Way Wireless Security Suite
TL260GS TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator Overview: The TL260GS is an Internet and GSM/GPRS Dual-Path alarm communication for Power Series PC1864/1832/1616 control panels Specifications: Dimensions : 3.937"x5.875"x0.625" (100mmx150mmx18mm) Weight : 320 g Antenna Gain : 2db Input Voltage : 11.1 to 12.6 V (from the Panel Bell output) Current Draw : 100 mA at 12V (400 mA during the GSM transmission) Operating Environment : 5 º C to 40º C (40º F to 104º F) READ SCREEN PASS MODULE AROUND 2-Way Wireless Security Suite

7 2-Way Wireless Security Suite
TL260GS TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator Features: Fully redundant Internet and GSM/GPRS dual-path alarm communication Integrated call routing Panel remote uploading/downloading support via GSM/GPRS and Internet Individual Periodic Test Transmission via GSM/GPRS and Internet Supervision heartbeats via GSM/GPRS and Internet 128-bit AES encryption via GSM/GPRS and Internet Full event reporting SIA format PC-Link connection SIM card included Signal strength and trouble display Activating and initializing through Connect 24 Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz READ SCREEN PASS MODULE AROUND 2-Way Wireless Security Suite

8 2-Way Wireless Security Suite
TL260GS TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator Compatible Control Panel: Control panel: Power Series PC1864/1832/1616 version 4.1 and higher Cabinet: PC5003C and PC4050C Compatible Receivers: Sur-Gard System I Receiver: version 1.10 and higher Sur-Gard System II Receiver: version 2.00 and higher Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver) Product Model and Accessories: TL260GS-USA: For US market with AT&T SIM card TL260GS-CDN: For Canada market with Roger SIM card GS-15ANTQ: Antenna Extension Kits with 15 feet cable GS-25ANTQ: Antenna Extension Kits with 25 feet cable GS-50ANTQ: Antenna Extension Kits with 50 feet cable READ SCREEN PASS MODULE AROUND 2-Way Wireless Security Suite

9 2-Way Wireless Security Suite
UL Approval List GS2060 GSM/GPRS Wireless Alarm Communicator TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator UL Commercial Burglary Listed as a primary communication channel (heartbeats must be enabled) Listed as a back-up in conjunction with the POTS (daily test transmission) Used as Dual Signaling Line Communication System (redundancy must be enabled) Used as Standard Line Security and Encrypted Line Security System (heartbeats and encryption must be enabled) UL Residential Burglary and Fire Listed as a primary communication channel (monthly test transmission) Listed as a back-up in conjunction with the DACT (monthly test transmission) 2-Way Wireless Security Suite

10 2-Way Wireless Security Suite
ULC Approval List GS2060 GSM/GPRS Wireless Alarm Communicator TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator ULC Commercial Burglary and Fire Listed as a passive communication module with Security Level P1, P2 and P3 (redundancy must be enabled) Listed as a active communication module with Security Level A1-A4 (heartbeats and encryption must be enabled) ULC Residential Burglary and Fire Listed as a primary communication channel (daily test transmission) Listed as a back-up in conjunction with the DACT (daily test transmission) 2-Way Wireless Security Suite

11 2-Way Wireless Security Suite
UL/ULC Listed Installation – Commercial Supervisory/Test Transmission Requirements Applications Communicator Setup Mode GS2060 TL260GS Primary Channel Backup Channel UL Commercial Burglary Primary 200 ms Daily Backup Optional ULC Commercial Fire Active 180 ms Passive ULC Commercial Burglary READ SCREEN NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations. 2-Way Wireless Security Suite

12 2-Way Wireless Security Suite
UL/ULC Listed Installation – Residential Supervisory/Test Transmission – Requirements Applications Communicator Setup Mode GS2060 TL260GS Primary Channel Backup Channel UL Residential Fire Primary Monthly Backup Optional UL Residential Burglary ULC Residential Fire Active Daily Passive ULC Residential Burglary READ SCREEN NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations. 2-Way Wireless Security Suite

13 GS2060/TL260GS – Installation and programming
2-Way Wireless Security Suite

14 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation BEFORE YOU BEGIN Have the following ready before installation: PC1864/1832/1616 Control panel with backup battery Battery connection harness PK5500 keypad with battery Screwdriver Prior to installing a GS2060 and TL260GS, contact your monitoring station to determine if it is a master reseller or visit and become an authorized dealer. In both instances, you will acquire a Profile Number, Installer ID Number and an Installer Password. Please NOTE: You need to activate the SIM card and initialize the communicator (step 1) 24 HOURS BEFORE INSTALLATION. All options of the communicator only could be programmed through Connect 24 READ SCREEN 2-Way Wireless Security Suite

15 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Summary of Installation Steps Step 1 – Initialize an account via Connect 24 Website ( Step 2 – Install and wire the communicator to the control panel (on-site) Step 3 – Load the programming and test for best signal strength location Step 4 – Program communication options on the control panel via keypad Step 5 – Test communication READ SCREEN 2-Way Wireless Security Suite

16 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 1 – Initialize an account via Connect 24 Website ( Login to Connect 24 website by using Installer ID and Password to initialize an account Select Profile Number Select Product Model Enter SIM card number Enter DNIS number (if necessary) Enter Account Code Select GPRS Periodic Test Transmission Interval (if necessary) Select Supervisory Type (if necessary) Enable DHCP (if necessary) Enter IP Address (TL260GS only when the installation is static IP) Enter Subnet Mask Address (TL260GS only when the installation is static IP) Enter Gateway Address (TL260GS only when the installation is static IP) Select Ethernet Periodic Test Transmission Interval (if necessary) Select Rate Plan Confirm information and submit activation application NOTE: You still can remotely change these options later via Connect 24 website. READ SCREEN 2-Way Wireless Security Suite

17 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 1 – 1 Select Profile Number READ SCREEN 2-Way Wireless Security Suite

18 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 1 – 2 Select Module Number READ SCREEN 2-Way Wireless Security Suite

19 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 1 – 3 Enter SIM Number READ SCREEN 2-Way Wireless Security Suite

20 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 1 – 4 Enter DNIS number Enter Account Code Select Supervisory Type Enable DHCP (if necessary) READ SCREEN 2-Way Wireless Security Suite

21 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 1 – 5 Enter IP Address (TL260GS only) Enter Subnet Mask Address (TL260GS only) Enter Gateway Address (TL260GS only) READ SCREEN 2-Way Wireless Security Suite

22 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 1 – 6 Select Plan Rate READ SCREEN 2-Way Wireless Security Suite

23 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 2 – 1 Install and wire the communicator to the control panel (on-site) Assemble the communicator with mounting bracket READ SCREEN 2-Way Wireless Security Suite

24 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 2 – 2 Install and wire the communicator to the control panel (on-site) Insert the communicator into the cabinet and assemble the antenna READ SCREEN 2-Way Wireless Security Suite

25 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 2 – 3 Install and wire the communicator to the control panel (on-site) Wire the communicator to control panel NOTE: See details in product manual for PC1864/1832/1616 control panel PCLINK Cable Connector Control panel: Red wire is on the right and black is on the left Communicator: Must be reversed (Black wire is on the right and red wire is on the left) READ SCREEN 2-Way Wireless Security Suite

26 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 3 – Load the programming and test for best signal strength location Ensure the SIM card is inserted Power up the control panel The communicator will be programmed by loading the pre-programmed configuration from Connect 24 automatically Check Green LEDs. You must achieve full or medium signal strength. See details in product manual. If signal strength is poor, must relocate the control panel or use an external extension antenna kits READ SCREEN 2-Way Wireless Security Suite

27 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 4 – Program communication options on the control panel via keypad GS2060/TL260GS with PC1864/1832/1616 control panel o Sections [301], [302], [303]: Program Communication Path • DCAA - Internal (Ethernet 1, Ethernet 2, GPRS 1, GPRS 2) o Section [350] : Program Communication Format (Communicator) • (If Option [301] (above) is set to DCAA, Option [350] must be set to SIA, sub-option 5) o Sections [351] to [376] : Program Call Direction o Section [382] : Enable T-LINK Interface (Option [5]) o Section [167] : Enable Communication Wait For ACK (Set to 60 seconds) o Section [401] : Enable DLS Session Through GPRS or Ethernet (Option [1]) READ SCREEN 2-Way Wireless Security Suite

28 2-Way Wireless Security Suite
Installation GS2060/TL260GS Installation Step 5 – Test communication 1. Disconnect incoming phone line from TIP and RING on the control panel 2. Verify that LED 2 is on, this indicate that the unit is active 3. Create an alarm transmission 4. Verify alarm transmission by calling monitoring station 5. Re-connect the phone line, if necessary For back-up communication applications, perform steps 1 to 5 For primary communication applications, perform steps 3 and 4 only READ SCREEN 2-Way Wireless Security Suite

29 2-Way Wireless Security Suite
Installation LED Display Trouble Status LED (Yellow – first one from the left) Please see details about the trouble shooting on page 17 in product manual 2-Way Wireless Security Suite

30 2-Way Wireless Security Suite
Installation LED Display Network Connection Status LED (Red – second one from the left) LED OFF No network connection issue present LED ON Physical Ethernet cable is not connected DHCP configuration fails Fails to get an IP address from the GPRS network GPRS connections has been reset LED blinks quickly once Ethernet transmitting LDE blinks quickly twice Ethernet receiving 2-Way Wireless Security Suite

31 2-Way Wireless Security Suite
Installation LED Display Signal Strength LED 2 (Green – third one from the left) Signal Strength LED 1 (Green – fourth one from the left) Green LED 2 blinks quickly once GPRS transmitting Green LED 2 blinks quickly twice GPRS receiving 2-Way Wireless Security Suite

32 2-Way Wireless Security Suite
Installation Keypad Trouble Display Trouble Condition General System Trouble Panel Event Buffer Description T-Link Network Fault/Restore includes SIM Lock Trouble GSM Trouble Ethernet Trouble Connect 24 Configuration Trouble T-Link Receiver Trouble/Restore includes Receiver Not Available Trouble Receiver Supervison Trouble FTC Trouble T-Link Comm. Fault/Restore includes Panel Absent Trouble 2-Way Wireless Security Suite

33 GS2060/TL260GS – Applications
2-Way Wireless Security Suite

34 2-Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Communicator Controlled Call Routing – Backup (dual-path) – Redundant (dual-path) Required Programming Panel Sections [301], [302] and [305] • Any of them could be programmed as DCAA DCAA (default): Ethernet 1 → Ethernet 2 → GRPS 1 → GPRS 2 Communicator Sections [005] Option [4] - Primary and backup path [ON]: GPRS path primary, Ethernet path backup [OFF]: Ethernet path primary, GPRS path backup Option [5] - Redundant between GPRS path and Ethernet path [OFF]: Disable redundancy [ON]: Enable redundancy NOTE: “Primary and Backup Path” and “Redundant Communication” options need to be configured during the initialization of the account via Connect 24. READ SCREEN 2-Way Wireless Security Suite

35 2-Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 1: Ethernet Primary, 4 Receivers READ SCREEN 2-Way Wireless Security Suite

36 2-Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 2: Ethernet Primary, 2 Receivers READ SCREEN 2-Way Wireless Security Suite

37 2-Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 3: GPRS Primary, 4 Receivers READ SCREEN 2-Way Wireless Security Suite

38 2-Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Backup Mode 4: GPRS Primary, 2 Receivers READ SCREEN 2-Way Wireless Security Suite

39 2-Way Wireless Security Suite
Applications GS/IP Call Routing (Internal) Redundant Mode: 4 Receivers – (Redundancy between GSM/GPRS path and Ethernet/Internet path) READ SCREEN NOTE: The application requires 4 different SG receivers or SG-DLR3 IP line cards 2-Way Wireless Security Suite

40 2-Way Wireless Security Suite
Applications Other Applications Periodic Test transmission Individual periodic test via GPRS and Ethernet Daily, Weekly and Monthly Interval Configured during the initialization of the account via Connect 24 Encryption 128 Bit AES Encryption Turned on by central monitoring station Sur-Gard receiver Encrypted communications enabled after next event sent to the receiver NOTE: Enabling this feature will require more data usage. Read-only Options from Keypad Read all the options of the communicator from LCD keypad Control panel option [851] READ SCREEN 2-Way Wireless Security Suite

41 2-Way Wireless Security Suite
Applications Other Applications Power Save Mode Extend the battery duration when an AC power loss on control panel Ethernet functionality turned off until a new event need to be transmitted Network Connections LED: OFF Incoming DLS connection will not be possible Hardware Default Reset the programming options to the factory setting (default values) NOTE: Please see details in product manual Software Update Update the firmware through DLS IV locally via PCLINK Update the firmware through DLS IV remotely via Ethernet/Internet (TL260GS only) READ SCREEN 2-Way Wireless Security Suite

42 2-Way Wireless Security Suite
Applications SIA Report Code Event SIA Data Code SIA Address Field Panel Absent Trouble ET Panel Absent Trouble Restore ER Radio Activation Restore RS Ethernet 1 Test Transmission RP GPRS 1 Test Transmission RP GPRS 2 Test Transmission RP FTC Restore YK Example: Nri0 ET001 N= New Event ri0=Partition/Area identifier ET= Panel Absent Restore 001=Zone 001 NOTE: GPRS 2 Test Transmission will only be sent when two different APNs are programmed. READ SCREEN 2-Way Wireless Security Suite


Download ppt "GS2060/TL260GS Product Technical Training"

Similar presentations


Ads by Google