Presentation is loading. Please wait.

Presentation is loading. Please wait.

Serial Attached SCSI Small Computer Serial Interconnect (SCSI) just got a whole lot smaller, faster & more versatile. Performance – Gen 1 at 300MBytes/sec.

Similar presentations


Presentation on theme: "Serial Attached SCSI Small Computer Serial Interconnect (SCSI) just got a whole lot smaller, faster & more versatile. Performance – Gen 1 at 300MBytes/sec."— Presentation transcript:

1 N5412A SAS Electrical Performance Validation and Compliance Test Software

2 Serial Attached SCSI Small Computer Serial Interconnect (SCSI) just got a whole lot smaller, faster & more versatile. Performance – Gen 1 at 300MBytes/sec per lane Scalability – Multi-port, long cables, up to 1.2GBytes/sec Reliability and Availability – Secondary failover, P2P Flexibility – Supports SAS & SATA drives and SCSI SW SAS Compliance Test Presentation

3 SATA Storage Market Segments
HDD/ODD Subsystems Components Storage Interconnect Heterogeneous Data Solutions HP Server/Brocade/EMC Storage Host Bus Adapters Semiconductors System Integrators Motherboards Allion Computer Faraday Technology Corp. Genesys Logic America Jmicron Technology Corp. LSI Logic LyCOM Technology NetCell Corporation Panasonic SILICONSTOR SUNEXT Design STMicroelectronics Marvell Silicon Image ACARD Technology Corp. Agere Systems Fujitsu Computer Products Hitachi GST Samsung Seagate STMicroelectronics Toshiba Western Digital Lite On Technologies Iomega Corp. Media Tek Inc. Philips Adaptec Addonics Technology AMCC Jmicron Technology LSI Logic Netcell Technology Pacific Digital Corp. 3Ware Intel Dell HP Scientific Atlanta ATI Technologies There are four main groups in the storage ecosystem – component manufacturers, subsystem manufacturers, storage interconnect manufacturers and system integrators. The component manufacturers are the people that develop the SATA/SAS controllers – these are companies like Marvell, Vitesse, etc. The subsystem manufacturers are the people that make disk drives – companies like Maxtor, Seagate, etc. The storage interconnect companies can be very broad – they develop HBAs, or Host Bus Adapters. Some of the larger companies in this area are Promise, and even Intel. The final piece of the ecosystem involves the system integrators – the people that are developing chipsets or integrating entire systems. These are companies like Intel, IBM, HP, etc. SAS Compliance Test Presentation

4 SAS Storage Market Segments
HDD Subsystems Components Storage Interconnect Heterogeneous Data Solutions HP Server/Brocade/EMC Storage HBA/RAID/Expander Semiconductors System Integrators Server / PC MB There are four main groups in the storage ecosystem – component manufacturers, subsystem manufacturers, storage interconnect manufacturers and system integrators. The component manufacturers are the people that develop the SATA/SAS controllers – these are companies like Marvell, Vitesse, etc. The subsystem manufacturers are the people that make disk drives – companies like Maxtor, Seagate, etc. The storage interconnect companies can be very broad – they develop HBAs, or Host Bus Adapters. Some of the larger companies in this area are Promise, and even Intel. The final piece of the ecosystem involves the system integrators – the people that are developing chipsets or integrating entire systems. These are companies like Intel, IBM, HP, etc. SAS Compliance Test Presentation

5 HDD Interfaces for Multi-user Market
(Gartner Ref. 3) SAS Compliance Test Presentation

6 Source: http://www.scsita.org
Market Trends Source: We’re primed to meet this major transition from existing parallel to serial! SAS Compliance Test Presentation

7 Market Trends Tek Compliance Test Tek’s solution is based on a 2003 version of the standard and offers no method of connectivity to the DUT! SAS Compliance Test Presentation

8 Market Trends Agilent Compliance Test
Tek Compliance Test Agilent’s solution is based on the 2005 version of the standard and directly leverages the UNH-IOL SAS test suite!!! SAS Compliance Test Presentation

9 N5412A is modeled after the industry standard
UNH-IOL SAS Test Suite is the industry standard. Interoperability testing starts at the PHY layer. Our solution is complete: Minimum of a 10GHz real-time scope Reference test loads and connectivity as per the specification Provide common tests and algorithms to the UNH-IOL solution SAS Compliance Test Presentation

10 Product Definition The N5412A SAS Electrical Compliance Test application: Supports Gen 1(1.5Gbps) and Gen 2(3Gbps) data rates Supports the IT, CT Transmit (TX) interfaces and the IR, CR Far-end Transmit (TX) interfaces Provides automated 81134A stimulus for OOB signal tests REQUIRES that the PHY (DUT) be able to generate CJTPAT, the Compliance Jitter Test Pattern, for testing Additionally, Agilent will provide the most common x2 internal drive/host test fixture (Zero-Length Test Load), Transient Test Fixture and Transmitter Compliance Transfer Function (TCTF) for the IT compliance point testing. SAS Compliance Test Presentation

11 N5412A SAS Electrical Compliance Test Coverage
The N5412A SAS Electrical Compliance Tests: Maximum/Minimum Rising Time. Maximum/Minimum Falling Time. Eye Inner amplitude(or minimum eye opening). Max peak to peak output amplitude. Maximum Noise during OOB idle time. Maximum transmitter device off voltage. Maximum transmitter output imbalance. OOB offset delta. OOB common-mode delta. Maximum jitter. Maximum skew. Maximum voltage at non-operational. Minimum OOB burst amplitude. Maximum Transients. Bit Rate. SAS Compliance Test Presentation

12 SAS Compliance Points SAS Compliance Test Presentation

13 SAS Interface Connector Descriptions
Type        Section     Ref. pg.    Connector ref.    Interface Name Internal       pg. 98      SFF-8482          SAS x2 Internal Plug Connector    SAS x2 Internal Cable Receptacle    pg. 99      SAS x2 Internal Backplane Receptacle Int. Wide      pg. 108     SFF-8484          SAS x4 Internal Wide Cable Receptacle Connector    pg. 109     SAS x4 Internal Wide Plug Connector    pg. 111     SFF-8087/86       SAS x4 Internal Compact Wide Plug Connector    pg. 112     SAS x4 Internal Compact Wide Receptacle Connector External       pg. 101     SFF-8470          SAS x4 External Cable Plug Connector    SAS x4 External Receptacle Connector    pg. 103     SFF-8088/86       SAS x4 External Compact Cable Plug Connector    pg. 104     SAS x4 External Compact Receptacle Connector SAS Compliance Test Presentation

14 SFF-8482 SAS x2 Internal Connectors
SFF-8482 Plug (Drive/Backplane / IT Interface) SFF-8482 Cable Receptacle / IR Interface SAS Compliance Test Presentation

15 SFF-8484 SAS x4 Internal Connectors
SFF-8484 Plug (HBA / IT Interface) SFF-8484 Cable Receptacle / IR Interface SAS Compliance Test Presentation

16 SFF-8470 SAS x4 External Connectors (
SFF-8470 Plug (Inter-Enclosure / CR Interface) SFF-8470 External Receptacle / CT Interface SAS Compliance Test Presentation

17 Simplistic Single-Port Server Configuration
A SATA host is analogous to a SAS initiator device; a SATA device is analogous to a SAS target device. Compliance is defined at the connectors for both buses. Connector Topology SATA x1 connector receptacle SAS Host: SFF-8482 receptacle SAS Device: SFF-8482 receptacle SAS Compliance Test Presentation

18 Simplistic 4-Port Server Configuration
A 4-port SAS controller (host bus adapter, usually PCI-X or PCIe to SAS) will have an internal x4 connector, and will fan out to four individual x1 connectors on SATA or SAS drives. In this case, only the primary port will be used and the secondary port remains unused. Connector Topology SAS Host: SFF-8484 receptacle SAS Device: SFF-8482 receptacle SAS Compliance Test Presentation

19 SAS Test Fixture Requirements
In general, SAS compliance testing will require: An adapter from the SAS connector to SMA A TCTF (omitted for ZLTL tests) A termination network (provided by scope 50-ohm terminations OR Transient Test Circuit) SAS Compliance Test Presentation

20 SAS x1 Internal (IT) Zero-Length Test Load
Far End Test Fixture (cable) H iSATA Text Fixture (Cable) Near End Test Fixture (Drive, HBA) H iSATA Test Fixture (Drive/Host) Used for physical layer electrical & impedance tests Used for cable impedance tests Available From CRUZ Systems (Worldwide Distribution) Internet: SAS Compliance Test Presentation

21 SAS x2 Internal (IT) Zero-Length Test Load & TCTF
Available now! N5421A SFF-8482 Test Fixture $3000 US DDP SAS Compliance Test Presentation

22 SAS x4 External (CT) Zero-Length Test Load
Available From Gore as IBNTST4X for $3800 SAS Compliance Test Presentation

23 SAS x4 External (CT) TCTF
Available From Molex upon request SAS Compliance Test Presentation

24 Complete SAS UNH-IOL TEST COVERAGE !
SAS Compliance Test Presentation


Download ppt "Serial Attached SCSI Small Computer Serial Interconnect (SCSI) just got a whole lot smaller, faster & more versatile. Performance – Gen 1 at 300MBytes/sec."

Similar presentations


Ads by Google