Download presentation
Presentation is loading. Please wait.
Published byLionel Wiggins Modified over 9 years ago
1
Mission: Stormwater Management Technology Pilot Projects, Monitoring, Modeling, Manuals, Training, Education The Low Impact Development Center, Inc. Balancing Growth and Environmental Integrity LID Modeling
2
Why are We Modeling? Determine Effectiveness Predict/Project (Pre-Post) Calibration “It’s Cheaper than Doing anything” NC State needs more PhD’s Regulatory Requirements Resource Protection
3
Hard Stuff Peak Flow Water Quality Energy (Light, Thermal, Stream Power) Habitat Optimization Maintenance Optimization Easy Stuff
4
How well do we maintain the ecological integrity (functions) of aquatic systems (small streams)? ChemicalVariables FlowRegime HabitatStructure EnergySources BioticFactors Nutrients Temperature D.O. pH Turbidity Organics Toxics Disease Reproduction Feeding Predation Competition Sunlight Nutrients Seasonal Cycles Organic Matter 1&2 Production Canopy Siltation Gradient Substrate Current Instream Cover Sinuosity Width/Depth Channel Morphology Soils Stability Riparian Vegetation Velocity Frequency Runoff Evaporation Ground Water Flow Duration Rain Intensity Scale / Spatial / Temporal / Species Ecosystem Integrity
5
Performance Measures Volume (Seattle Sea Streets) Prescriptive or Presumptive Load vs. Percentage Flow Rate (Discrete or Continuous)
6
Taxonomy and Classification Design Models Calibration Models Coordinating Needs Critical
7
Early Models
8
Simple WQ Stuff L = Load, P=Precipitation
9
Courtesy Geoanalysis
10
Today Moving towards Tributary Strategies Loadings and Limits (303d) Site Design Models don’t link to Watershed Models Rapid Assessments that may have significant data or science gaps Costs and Predictability unknown
11
Civil to Environmental Q = CIA
12
Bioretention
13
RECHARGE HYDROLOGIC CYCLE: P+R+E+T
14
Optimization A bioretention pond costs $2,000 to construct for a ½ site. So it costs $4,000 per acre. First, it’s a cell not a pond!! Region of Feasibility Gazillions of Acceptable Solutions
15
Conventional Pipe and Pond Centralized Control “Efficiency”
16
LID Uniform Distribution of Micro Controls
17
McCuen 2002 III II I Runoff Hydrograph is Sensitive to Bioretention Placement in II only 7 3 I II III
18
Hoffman and Crawford, 2000
19
Existing Problems and Future High Risks Hoffman and Crawford, 2000
20
Remove Large Impervious Areas Oversize Pipes Comparison of Conventional and LID Strategies
22
An estimate of imperviousness can be derived directly from the satellite image for developed areas. (Water bodies from the USGS topographic maps are overlaid for orientation, and areas identified as undeveloped in the National Land Cover dataset are left white.)
23
Soil moisture maps can be generated using the vegetation and surface temperature data with a surface climate model. The gray-scale image is dark for surfaces with a dried out top layer and bright or white for surfaces that are wet. This information can be used to locate areas with very moist surface layers near identified wetlands that can be easily converted to wetlands themselves. woody wetlands classified by the National Land Cover Dataset (NLCD ) forested, non-tidal wetlands classified by the Army Corps of Engineers
24
Defining LID Technology Major Components 1. Conservation (Watershed and Site Level ) 2. Minimization (Site Level) 3. Strategic Timing (Watershed and Site Level) 4. Integrated Management Practices (Site Level) Retain / Detain / Filter / Recharge / Use 5. Pollution Prevention Traditional Approaches
25
“Initial” Low-Impact Development Hydrologic Analysis and Design Based on NRCS technology, can be applied nationally Analysis components use same methods as NRCS Designed to meet both storm water quality and quantity requirements
26
Q T Developed Condition, Conventional CN (Higher Peak, More Volume, and Earlier Peak Time) Existing Condition Hydrograpgh Pre/ Post Development Losses
27
Q T Developed Condition, with Conventional CN and Controls Existing Additional Runoff Volume Developed Existing Peak Runoff Rate Detention Peak Shaving
28
Q T Developed Condition, with LID- CN no Controls. Existing Reduced Runoff Volume Developed- No Controls Reduced Q p Minimize Change in Curve Number
29
Q T Developed, LID- CN no controls same Tc as existing condition. Existing More Runoff Volume than the existing condition. Developed, LID-CN no controls Reduced Q p Maintain Time of Concentration
30
Q T Provide Retention storage so that the runoff volume will be the same as Predevelopment Retention storage needed to reduce the CN to the existing condition = A 2 + A 3 A3A3 A2A2 A1A1 Reducing Volume
31
Q T Provide additional detention storage to reduce peak discharge to be equal to that of the existing condition. Existing Predevelopment Peak Discharge Detention Storage
32
Q T Comparison of Hydrographs A2A2 A3A3 LID Concepts Conventional Controls Existing Increased Volume w/ Conventional
33
Q T 2 3 4 1 5 6 7 Hydrograph Summary 2 3 4 1 Existing Developed, conventional CN, no control. Developed, conventional CN and control. Developed, LID-CN, no control. Developed, LID-CN, same Tc. Developed, LID-CN, same Tc, same CN with retention. Same as, with additional detention to maintain Q. 6 5 6 7 Pre-development Peak Runoff Rate
34
Disconnecting Impervious Areas to Reduce CN CN c = CN p + (P imp /100) (98-CN p ) (1-0.5 R) Where: CN c = Composite Curve Number CN p = Pervious Curve Number P imp = Percent Impervious R = Ratio of Disconnected to Total Imperviousness
35
Comparison of Conventional and LID Site Conditions
36
Comparison of Conventional and L I D Curve Numbers (CN) for 1- Acre Residential Lots Conventional CN 20 % Impervious 80 % Grass Low Impact Development CN 15 % Impervious 25 % Woods 60 % Grass Curve Number is reduced by using LID Land Uses.
38
8% BMP Determining LID BMP Size Basic Idea: If you can maintain Tc, storage capacity can be based on curve number difference only.
39
LID Manual H and H Process
40
Comparison of Conventional and L I D Curve Numbers (CN) for 1- Acre Residential Lots Conventional CN 20 % Impervious 80 % Grass Low Impact Development CN 15 % Impervious 25 % Woods 60 % Grass Curve Number is reduced by using LID Land Uses.
41
Q T Developed Condition, with LID- CN no Controls. Existing Reduced Runoff Volume Developed- No Controls Reduced Q p Minimize Change in Curve Number
43
Source Node Gross Pollutant Trap Buffer Strip Vegetated Swale Infiltration Dry & Wet Detention Pond Wetlands
46
BMP Evaluation Computer Module Prince George’s County, Maryland
47
Target Pollutants Suspended Solids Nutrients –Nitrogen (nitrate, ammonia, organic nitrogen) –Phosphorus Metals (copper, lead, zinc) Oil & Grease
48
HSPF LAND SIMULATION – Unit-Area Output by Landuse – BMP Evaluation Method Existing Flow & Pollutant Loads Simulated Flow/Water Quality Improvement Cost/Benefit Assessment of LID design BMP DESIGN – Site Level Design – SITE-LEVEL LAND/BMP ROUTING Simulated Surface Runoff N.B.: Good design may need to go beyond period of record.
49
Phosphorus Lead Calibrated BMPs!!!
50
HSPF Land Use Representation
51
BMP Physical Processes Possible storage processes include: –Evapotranspiration –Infiltration –Orifice outflow –Weir-controlled overflow spillway –Underdrain outflow –Bottom slope influence –Bottom roughness influence –General loss or decay of pollutant (Due to settling, plant-uptake, volatilization, etc) –Pollutant filtration through soil medium (Represented with underdrain outflow) Depending on the design and type of the BMP, any combination of processes may occur during simulation
52
Overflow Spillway Bottom Orifice Evapotranspiration Infiltration Outflow : Inflow: Modified Flow & Water Quality From Land Surface Storage BMP Class A: Storage/Detention Underdrain Outflow
53
BMP Class B: Open Channel Outflow: Inflow: From Land Surface Overflow at Max Design Depth Open Channel Flow Evapotranspiration InfiltrationUnderdrain Outflow Modified Flow & Water Quality Modified Flow & Water Quality
54
Holtan Infiltration Model veg. parameter void fraction soil porosity soil f c D u (A) background f c D s
55
General Water Quality First Order Decay Representation Mass 2 = Mass 1 x e – k t Pollutant Removal is a function of the detention time
56
Underdrain Water Quality Percent Removal Mass out = Mass in x (1 - PCTREM) Underdrain percent removal is a function of the soil media Mass in = Surface conc * underdrain flow
60
Soil moisture maps can be generated using the vegetation and surface temperature data with a surface climate model. The gray-scale image is dark for surfaces with a dried out top layer and bright or white for surfaces that are wet. This information can be used to locate areas with very moist surface layers near identified wetlands that can be easily converted to wetlands themselves. woody wetlands classified by the National Land Cover Dataset (NLCD ) forested, non-tidal wetlands classified by the Army Corps of Engineers
61
Ground Truthing Image
62
Moving From Calibrated “Sophisticated” Watershed Models to Design Tools
63
Milwaukee Metropolitan Sewer District (MMSD) LID Model Ideas from LID awareness conference/seminar Local Builder liked it and is using it School programs on planting trees and reducing asphalt Keeper of the mega model liked idea
64
Model Highlights Need retrofit technologies for highly impervious areas Need retrofit approach for build out of conventional and centralized areas Need simple analysis tools for engineers
65
Highlights of approach Volume based to control low peak rate (x cfs/acre) Uses NRCS Methods Outputs to NRCS Methods Includes “Typical LID CNs Limited Input Graphical Output Minimal Training Transparent (No Big Black Box)
66
IMP’s CN’s Event and Area Uncontrolled
67
Instant Graphing of Results (including detention/retention)
68
Readhyd Card for TR-20
69
Limitations Accounting on a watershed scale Link to WQ model and WQ calcs ROUTING!!! No groundwater recharge End of pipe answer Size (15 meg) no emailing here
70
Who else is doing this type of Modeling Stuff New Jersey (includes groundwater recharge component, YEAH!!!) North Carolina Delaware (DURMM) Virginia COE (Checklist) Puget Sound (HSPF) WinSlamm Proprietary Engineering Vendors (PCSWMM for Pavers Unilock™)
73
Where to go from here? Multimedia and calibrated models Clearinghouses and Databases on effectiveness (ASCE) More rigorous calibrated models Optimization!!! Better Costing WWW.LID-Stormwater.net/Clearinghouse
Similar presentations
© 2025 SlidePlayer.com. Inc.