Scope To convert manual or PLC based autoclave to a dedicated and fully automatic system. Existing product with Heater and low water sensor (Bimetallic or other). Water Inlet/outlet valve, Vacuum inlet/outlet valve, Steam Inlet/outlet. Any specific requirement specification based on knowledge sharing. Input Technical Documentation including user manual, assembly manual, service manual, wiring diagram, system installation training etc. and production training. Tested and ready to use control system based on per unit rate. Deliverables Safe and reliable solution to meets international standard for high pressure equipment. To meet Bowie & Dick Equipment control algorithms and sequence. Confidential © Real Time Consultant Case Study: Automatic Autoclave/ Sterilizer Selectable temperature of 121 or 135 Degrees Celsius. Automatic operation through all the Bowie & Dick Equipment control cycles. Thermal printer based report generation. Microcontroller based digital and graphical indication for Temperature, Pressure, Lapse time and executed cycle status. Datalogging: 1000 record with complete details. Fuzzy logic based solenoid valve control for precise temperature, pressure, vacuum (Vacuum pump), drying cycle, water feed control. Water quality measurement and display parameter pH and TDS. Challenges Value Addition
2
Confidential © Real Time Consultant Automatic Autoclave/ Sterilizer-Basic
3
Confidential © Real Time Consultant Automatic Autoclave/ Sterilizer-Advance
4
Confidential © Real Time Consultant Automatic Autoclave/ Sterilizer
5
Confidential © Real Time Consultant Area of co-operation Product Design as per given specification. Ready to use solution based on Embedded H/W and Software. We deliver ready to use solution for your product with latest feature and requirement. Latest technology to meets international standard and feature. Complete customization of product as per customer requirement. Product design as per IEC/UL standard guideline (Safety :IEC60601-1 and EMI-EMC: IEC60601-1-2) Sourcing. Vendor development. Mechanical Design Support. Free onsite support and evolution sample available. No development charges, only per unit rate is charged after product approved by the customer.
6
Confidential © Real Time Consultant Automatic Autoclave/ Sterilizer Contact for support and evaluation sample. Real Time Consultant Delhi: B-232/1, Chatterpur Extn. Mehrauli-110074. 09350831213, 09958700553. Mumbai: 101, A-Wing, Lake Bloom Appartment, Andheri (E), Powai, Mumbai 09322245924
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.