Download presentation
Presentation is loading. Please wait.
Published byMilton Newman Modified over 9 years ago
1
Power Distribution for the LAr calorimeters for the HiLHC
Marco Riva Università degli Studi di Milano on behalf of the INFN-APOLLO collaboration M. Alderighi(1,6), M. Citterio(1), M. Riva(1,8), P. Cova (3,10), N. Delmonte(3,10), A. Lanza(3), R. Menozzi(10), A. Paccagnella (2,9), F. Sichirollo(2,9), G. Spiazzi(2,9), M. Stellini(2,9), S. Baccaro(4,5), F. Iannuzzo(4,7), A. Sanseverino(4,7), G. Busatto(7), V. De Luca(7) (1) INFN Milano, (2) INFN Padova, (3) INFN Pavia, (4) INFN Roma, (5) ENEA UTTMAT, (6) INAF, (7) University of Cassino, (8) University of Milano, (9) University of Padova, (10) University of Parma
2
Outlines APOLLO project:
Power Distribution Proposal for the LAr Calorimeter Design and preliminary tests of the Main Converter and PoL Engineering Issues: Thermal Design; Magnetic Materials with High saturation; Analog/Digital/Power Devices selection: Behavior in radiated environment Goodmorning December 6, 2011 sLAr Electronics Meeting - M. Riva
3
The APOLLO Project: LV Power Supplies For The Next High Energy Physics Experiments
Full replacing the present systems whose design dates from early 2000 years: new and improved design possibility; Minimization of power loss in cables used for carrying current from PS distributors to the front-end of detectors push the distributors as close as possible to the front-end; New and more severe environment requirements: Increased rad-hard performance, because of the increased luminosity of accelerators; Increased B-tolerance of systems getting closer to detectors and magnets; Better reliability and controls, in order to reduce access time and increase the overall detector efficiency; Avoiding industrial intellectual property, trying to implement the CERN Open Hardware policy; The main goal of the APOLLO project is to investigate and propose a LV Power Supplies Distributed Architecture suitable for the Next High Energy Physics Experiments. In order to define the new needs it worthwhile underline the present increased demand of integration of the electronics with detectors at the design level, to avoid both mechanical and electrical criticalities: This new trend has some drawback and, in fact, it requires: a careful design in terms of EMC; Necessity of rad-hard devices, so to place modules in the experimental caverns; Necessity of B-tolerant systems, to be able to place them close to detectors; The activities of the APOLLO project used as test case the power distribution architecture of the LAr calorimeter. December 6, 2011 sLAr Electronics Meeting - M. Riva
4
Power Distribution Architecture for LVPS: Present status
19 Low drop-out regulators/FEB Just to mention this slide reports the present Power distribution architecture adopted for the Lar calorimeter used as test case example. We can see …. ATLAS Experiment Power Distribution System for the FEB of the LAr Calorimeters December 6, 2011 sLAr Electronics Meeting - M. Riva
5
Power distribution architectures
Centralized Power Architecture (CPA): An isolated DC/DC converter generates the whole set of regulated DC voltages (±12V, ±5V and +3.3V) supplying the circuit subsystems. Decentralized Power Architecture: The low voltage distribution is moved close to the load by means dedicated converters; Distributed Power Architecture (DPA): A single intermediate DC bus (+48V or +12V) is generated by a main converter Intermediate Bus Architecture (IBA) In addition to the generation of a main voltage bus (48V-76V), a second set of BUS voltages are provided (8V-14V). Lower voltages are given by the point-of-load converters. Spot Power Architecture Intermediate solution between CPA and DPA. In addition to the voltage bus typical of DPA, one or more voltage lines supply the circuits directly. Factorized Power Architecture (FPA) A “factorized” bus (26V-55V) not stabilized and not galvanic insulated supply the POL by means dedicated converters. High number of long connection cables (penalty in volume and weight) Low flexibility High losses mainly in unique hot spot + losses in linear regulator LDO Possible cross-talk effect between the power supply. High Voltage Drop Improvement in the efficiency Independent control of the different loads Not optimal solution considering weight and size High number of devices Low Voltage Drop Optimized Voltage Drop High static regulation and improvement of the dynamic performances (the impact of the series resistance and inductance is reduced) The DPA approach benefit from increased efficiency, low size and weight Several types of power supply distribution architectures, specific devoted to servers farm, high performance PCs, have been introduced in the last decade and are today employed. Their electrical characteristics are determined by the evolution of digital circuits, whose switching frequencies moved to the GHz range and supply voltages reduced down to the level of 1V with a correspondent increase of the current demand. Centralized Power Architecture (CPA): it's based upon an isolated DC/DC converter, that generates the whole set of regulated DC voltages (typically ±12V, ±5V and +3.3V) supplying the circuit subsystems. Distributed Power Architecture (DPA): A single intermediate DC bus (typically +48V or +12V) is generated by an off line converter, consisting in a Power Factor Converter (PFC) and a main DC to DC converter. The bus voltage is reduced to lower levels by means of point-of-load DC/DC converters located directly on the motherboards close to the loads. Intermediate Bus Architecture (IBA) In addition to the generation of a main voltage bus, as in the DPA but typically higher (48V-76V), a second set of PCB bus voltages is provided (8V-14V). Then lower voltages are given by the point-of-load converters. Spot Power Architecture It is an intermediate solution between CPA and DPA. In addition to the voltage bus, typical of DPA, one or more voltage lines supply the circuits directly. Factorized Power Architecture (FPA) A “factorized” bus (26V-55V) not stabilized and not galvanic insulated it is used to supply the POL by means of dedicated high frequency isolated converters. (VTM: Voltage Transformer Module; PRM: Pre-Regulator Module) The studies didn't show a clear evidence of a best solution over the others leaving the choice of the more suitable to the designers. Factorized Power Architecture December 6, 2011 sLAr Electronics Meeting - M. Riva
6
The APOLLO proposal – System architectures
Upgrade from “Centralized Power Architecture” to “Distributed Power Architecture” Rationalization of the number and level of the voltages required by FEBs only few intermediate voltages must be supplied (one or two) loads must be served by PoLs regulators Possibility of adopting non-traditional topologies: modular approach (possible benefit for other detectors) higher switching frequency optimized design of magnetic devices minor losses and heat reduced voltage across devices In order to face the new exigency of electrical power request, high reliability and efficiency of the upgrade phase the APOLLO proposal consists in the developing of a Distributed Power Architecture constituted by: December 6, 2011 sLAr Electronics Meeting - M. Riva
7
Proposed Power Distribution Scheme
CRATE FEB #3 POL LDO Converter FEB #2 FEB #1 PoL niPoL Converter Main DC/DC Converter 280 Vdc Regulated DC bus The movement of the power distributors close to the detector reduce the power converter complexity but increase the design of the whole system with few critical active devices… 12Vdc5% High DC conversion ratio converters PoL = Point of Load 48Vdc5% December 6, 2011 sLAr Electronics Meeting - M. Riva
8
Distributed Power Architecture proposal for the Moun Detector
Case study: The DC/DC Power Converter adopted for the Moun Detector could benefit from the modular approach adopted in LAr calorimeter. Muon Detector POL LDO Converter Chamber #1 PoL niPoL Converter Chamber #3 Chamber #2 Main DC/DC Converter 280 Vdc The standardization of the MC modules (they are not more connected to the Loads requirements) makes possible their re-use in other power distribution architectures: Characteristics: Main isolated converter with N+1 redundancy High DC bus voltage (12V or more) Distributed Non-Isolated Point of Load Converters (niPOL) with high step-down ratio, installed on-chamber and high B-tolerant (more than 2T) coreless inductance in air Regulated DC bus December 6, 2011 sLAr Electronics Meeting - M. Riva
9
High radiation & magnetic field tolerance
Critical problems Electromagnetic immunity of the front-end electronics to the switching converters Converters Design (Main and PoLs) Number and levels of intermediate voltages How many? Positive and negative? Which levels? High for loss reduction or lower for a reasonable POL design (voltage ratio)? Redundancy N+1 (single failure tolerance) Modular approach: number of modules Vs total power oversizing Thermal design Power losses distribution Analog/Digital/Power Devices Active switches selection Power and voltage level Switching frequency MOSFETs, SiC, GaN Analog/Digital Controllers PWM Controllers Drivers Signal Isolators FPGAs Design of magnetic parts Coreless devices Low permeability cores Thermal analysis Water cooled In order to fully investigate the criticality of the proposal some main items has been individuated : In the following we discuss the approaches followed by APOLLO High radiation & magnetic field tolerance December 6, 2011 sLAr Electronics Meeting - M. Riva
10
Preliminary FEB EM Noise Tolerance Tests with PoL Converter
Jim Kierstead, Sergio Rescia, Hucheng Chen, Francesco Lanni (Brookhaven National Laboratory) LTM4602 – 6A High Efficiency DC/DC μModule Complete Switch Mode Power Supply Wide Input Voltage Range: 4.5V to 20V 6A DC, 8A Peak Output Current 0.6V to 5V Output Voltage 1.5% Output Voltage Regulation Up to 92% Efficiency Output Over Voltage Protection IR3841 – Integrated 8A Synchronous Buck Regulator Greater than 96% Maximum Efficiency Wide Input Voltage Range: 1.5V to 16V Wide Output Voltage Range: 0.7V to 0.9*Vin Continuous 8A Load Capability Programmable Switching Frequency up to 1.5MHz Programmable Over Current Protection Thanks to the cooperation with BNL EM tolerance of FEB on POLs emission have been tested December 6, 2011 sLAr Electronics Meeting - M. Riva
11
Summary of the preliminary EM tests
Irradiated noise of PoL Converters Outside FEC: Negligible effect on coherent noise Inside FEC: Shielding is necessary to achieve good noise performance inside FEC Conducted noise of PoL Converters December 6, 2011 sLAr Electronics Meeting - M. Riva
12
The APOLLO proposal - MC
The Main Converter is based upon a DC-DC Phase Shifted Converter well suited for multi-outputs, or-ed connection and constant load supply (single pole dynamic). The whole unit is constituted by 3 modules connected in parallel: Vin=280 V Vout= 12V Pout= 1.5 kW fs=100kHz The supervisor and protections are demanded to an external interface: current Sharing start-up control/failure clock, phase shift between the modules, Alarms December 6, 2011 sLAr Electronics Meeting - M. Riva
13
Switch In Line Converter
Merits High switching frequency Fixed switching frequency Soft switching commutation (use of parassitics elements: leakeage inductance) Single pole dynamics Well suited for multiple outputs Suited for or-ed outputs Reduced MOS drain-source voltage Non-isolated feedback available The topology proposed is shown in the figure. The original circuit was introduced few years ago by the electronic section of the university of Milan and it gained popularity since it was used in the power distribution system on-board the international space station for the non-US apparatus. Due to the particular disposition of the active switches it is called "Switch In Line Converter" (SILC). The circuit consists in the series connection of two half bridge converters (lower HB and upper HB) controlled by a PWM phase shifted operation. Each half bridge switches with 50% duty-cycle. The power flowing is controlled by the shift-delay between the upper half bridge commands and the lower one. During the on transition of each MOSFET a resonance between the inductor L and the parasitic capacitors allows soft switching (ZVS) Drawbacks High drain current levels High number of large capacitors December 6, 2011 sLAr Electronics Meeting - M. Riva
14
How SILC topology works
A short overview of the basic operations of the circuit is reported. Reference is made to steady state conditions and to the ideal switching sequence Connections in parallel are allowed because the SILC power cell acts like a current controlled generator. The transfer power occurs during the time slots putted into evidence by shadow area. The input voltage partition due the series connection of the half bridges, reduces the voltage stress of the MOSFETs and the voltage gap to span during the resonant transition. This allows stretching the soft-switching persistence for a wider power range as compared with other PWM phase shifted topologies. The initial status, at t =t 0- , of the switches is: S1 OFF, S2 ON, S3 OFF, S4 ON. At t=t0+ S4 turns OFF; the current IL flows through Cp4 and Cp3 during the soft-switching interval until D3 clamps; S3 turns ON at t=t1- . Then, since the voltage across L is -2V0 , IL decreases and reverses its polarity until it reaches the values max , -IL at t=t2−, when S2 turns OFF and the output rectifiers too. Current balance in the transformer implies that It1+ItL=It1-ILmax=0, hence max , It1=ILmax. Another resonant voltage clamped transition, identical to the previous one, occurs at node 1. Switch S1 turns ON at t=t3- after clamping of D1. From t3 t4 the current IL remains constant; in this interval the Kirchoff law implies IL+IT1=I0, where IO is the output current reflected at the primary side of the transformer. When S3 switches OFF (t=t4-), the second half period begins and it exactly mirrors the first one. The period ends at t=t8+=t0+T. IL t December 6, 2011 sLAr Electronics Meeting - M. Riva
15
Power Transformer Design
The transformer is constituted by 2 primary windings and 1 low voltage secondary winding (5:5:1) traditional windings planar structure X The whole transformer has been divided in 4 subsystems Each subsystem consists by 10 turns for each primary windings and 2 turns for the center tapped secondary. The secondary has been realized by means of the parallel connections of 2 windings in order to reduce the output leakage inductance. December 6, 2011 sLAr Electronics Meeting - M. Riva
16
“Subtransformer” Design
The windings of each subsystems are realized by means of a 22 layers PCB 4 layers Thermal Layer for heat dissipation 4.71mm 22 layers 10 layers 2 turns for every layers 4 layers UL94V-0 December 6, 2011 sLAr Electronics Meeting - M. Riva
17
Single Module View 315 60 130 December 6, 2011
sLAr Electronics Meeting - M. Riva
18
Experimental Tests Open loop operation:
Ch1) gate-source command of the lower MOS Ch2) inductor current Ch3) M1 drain-source voltage Ch4) M3 drain-source voltage Efficiency Vs Output Power December 6, 2011 sLAr Electronics Meeting - M. Riva
19
Dynamic measurement: Gloop
Control to Output (Gloop) dependency from output power December 6, 2011 sLAr Electronics Meeting - M. Riva
20
Design of PoL Converter: Synchronous Buck
The requirement of high B (2-4T) makes mandatory the use of coreless solution (inductance in air); The value of the inductance is limited to few 100nH; High current ripple (DiLpp > 2IL) -> High C in order to limit the output ripple High switching frequency December 6, 2011 sLAr Electronics Meeting - M. Riva
21
Multiphase Synchronous Buck (interleaved)
SL1 SH1 SL2 SH2 - + ug uo iL1 iL2 iLtot Switches command delayed of TS/n with n number of phase (2 in figure) iL1 iL2 iLtot Io/2 Io Fsw 2·Fsw t TS/2 TS SH1 SH2 Limitation of the output ripple December 6, 2011 sLAr Electronics Meeting - M. Riva
22
Current Ripple Cancellation
Vo=1.3 V 12 V 5 V Input voltage 1 D=0.5 for the best cancellation effect 0.9 0.8 0.7 Two phases 0.6 Ripple Ratio 0.5 0.4 0.3 0.2 0.1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Duty cycle 1 0.9 0.8 The interleaved solution can benefit from a current ripple compensation which requires however high number of phase and low duty cycle proportional to the voltage ratio 0.7 Four phases D=0.25, 0.5, for the best cancellation effect 0.6 Ripple Ratio 0.5 0.4 0.3 0.2 0.1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Duty cycle December 6, 2011 sLAr Electronics Meeting - M. Riva
23
Interleaved Buck with Voltage Divider - IBVD
S1 S2 S3 S4 L1 Co R C1 L2 Ug uo + - uC1 i1 i2 Phase shift TS/2 D<50% Uo = UgD/2 e UC1 = Ug/2 D>50% Uo = UgD2 e UC1 = Ug(1-D) December 6, 2011 sLAr Electronics Meeting - M. Riva
24
How IBVD works: D < 0.5 0 < t < DTS iL2 iL1 iC1 iL1+iL2 S1 S2
-iL1 S1 S2 L1 iL1 + Ug + uo uC1 C1 S4 Co Ro iC1 L2 iL2 S3 0 < t < DTS December 6, 2011 sLAr Electronics Meeting - M. Riva
25
How IBVD works: D < 0.5 DTS < t < TS/2 iL2 iL1 iC1 iL1+iL2 S1
-iL1 S1 S2 L1 iL1 + Ug + uo uC1 C1 S4 Co Ro iC1 L2 iL2 S3 DTS < t < TS/2 December 6, 2011 sLAr Electronics Meeting - M. Riva
26
How IBVD works: D < 0.5 TS/2 < t < TS/2+ DTS iL2 iL1 iC1
-iL1 S1 S2 L1 iL1 + Ug + uo uC1 C1 S4 Co Ro iC1 L2 iL2 S3 TS/2 < t < TS/2+ DTS December 6, 2011 sLAr Electronics Meeting - M. Riva
27
How IBVD works: D < 0.5 TS/2+ DTS < t < TS iL2 iL1 iC1
-iL1 iL1 iL2 L2 L1 S2 S4 S1 S3 Ug uo Ro Co C1 + iC1 uC1 TS/2+ DTS < t < TS December 6, 2011 sLAr Electronics Meeting - M. Riva
28
How IBVD works: D < 0.5 iL2 iL1 iC1 iL1+iL2 iL1 iL2 L2 L1 S2 S4 S1
-iL1 iL1 iL2 L2 L1 S2 S4 S1 S3 Ug uo Ro Co C1 + iC1 uC1 December 6, 2011 sLAr Electronics Meeting - M. Riva
29
Interleaved Buck with Voltage Divider
S1 S2 S3 S4 L1 Co R C1 L2 Ug uo + - uC1 i1 i2 High step-down ratio Reduced current in each inductor Increased of the equivalent frequency in the output filter Reduced switch voltage stress (Uin/2): ZV switch turn-on Interleaved operation with automatic current sharing and ripple cancellation High number of passive elements High complexity of the control circuit December 6, 2011 sLAr Electronics Meeting - M. Riva
30
IBVD: experimental characterization
Input Voltage: Ug = 12 V Output Voltage: Uo = 2.5 V Output Current: Io = 3A Size: L = 6cm, W = 4.2cm output Single buck input Cin = 100nF + 10mF Co = 2x47nF + 2x47mF + 2x10mF L = 90nH – 30mW Q1,2 = 2xIRF8915 IBVD Cin = 100nF + 10mF Co = 2x47nF + 4x2.2 mF C1 = 2x470nF (1206) L1 = 161nH – 58mW L2 = 169nH – 63mW S1,4 = IRF8915 fs = 1MHz December 6, 2011 sLAr Electronics Meeting - M. Riva
31
Efficiency comparison @ fs = 2MHz
December 6, 2011 sLAr Electronics Meeting - M. Riva
32
High Current IBVD Input Voltage: Ug = 12 V Output Voltage: Uo = 2 V
Output Current: Io = 20A Switching Frequency: fs = 280 kHz 2.2 mH (iron core inductance) Size: L = 7cm, W = 3.5cm Co C1 Cin L1 L2 S1 S3 S4 S2 S1 S2 S3 S4 L1 Co R C1 L2 Ug uo + - uC1 i1 i2 Control circuit on the other side of the PCB December 6, 2011 sLAr Electronics Meeting - M. Riva
33
IBVD IBVD Efficiency Output current [A] 0.78 0.8 0.82 0.84 0.86 0.88 5
10 15 20 IBVD Efficiency Output current [A] December 6, 2011 sLAr Electronics Meeting - M. Riva
34
Thermal Modeling – Top-Down Approach
Water cold plate System Level boards and cold plate position Board Level main heating devices modules layout heating convection and conduction Device Level package definition heating exchange between single components December 6, 2011 sLAr Electronics Meeting - M. Riva
35
Modeling (and Simulations) @ System Level
3D Thermo-fluidynamic FEM of working and faulty converters Liquid Cooled Chassis: 2 mm 1510 steel case containing 3x1kW main converter modules cooled by cold plates Outiside crate Liquid Internal surface 18°C 29°C 35°C Outlet water temperature required 25°C Maximum cold plate internal temperature: 35°C (The power losses distribution have been supposed uniform !) December 6, 2011 sLAr Electronics Meeting - M. Riva 35
36
Simulation in case of failure
3D Thermo-fluidynamic FEM of working and faulty converters Liquid Cooled Chassis: 2 mm 1510 steel case containing 2x1.5kW main converter modules cooled by cold plates Outside crate Liquid Internal Surfice 18°C 45°C 34°C Maximum cold plate internal Temperature 45°C External Wall 18°C GOOD (required: 18 °C) December 6, 2011 sLAr Electronics Meeting - M. Riva 36
37
Modeling @ Device Level
Packages: TO-220 and D2PAK Device Model Layers considered: (1) FR (2) IMS (3) FR4+Slcn (4) FR4 with thermal vias M. Bernardoni et al., ESREF’09, Arcachon (F), 5-9 ott December 6, 2011 sLAr Electronics Meeting - M. Riva 37
38
Simulation of different packages
(1) FR4 (2) IMS (4) Th. vias (3) FR4+Slcn December 6, 2011 sLAr Electronics Meeting - M. Riva 38
39
Thermal modeling of Planar Transformer
Physical dimension and material definition Thermal simulation Building mesh December 6, 2011 sLAr Electronics Meeting - M. Riva
40
Modeling @ Board Level: the MC prototype
Rif. N° Device PD [W] 1 MOSFET MC (TO247) 5 2 Planar Trasf. - Core 100 3 Planar Trasf. – Windings 65 4 Diode (ISOTOP) 35 Inductor 6 Cu traces for the secondary 7 MOSFET AUX (TO247) 0,1 8 AUX Transf. – Core 0,5 9 AUX Transf. – Windings 10 AUX MOSFET (D2PAK) 11 Capacitors <0,1 Total Power Loss 217 December 6, 2011 sLAr Electronics Meeting - M. Riva 40
41
FE Physical definition and meshing
Mesh with freedom levels December 6, 2011 sLAr Electronics Meeting - M. Riva
42
Simulation Results Maximum temperature acceptable (considering Text = 28 °C) December 6, 2011 sLAr Electronics Meeting - M. Riva
43
Thermal measurements Vs simulations
The experiment has been done with air cooling system Pout = 1.2 kW (Iout 100 A) December 6, 2011 sLAr Electronics Meeting - M. Riva 43
44
Planar Transformer Tests in Bstat
The behavior of the planar transformer and in particularly of the low permeability magnetic core (Koolm by Magnetics) has been tested in condition close to the normal operation : Vcc=70, fs=100kHz. December 6, 2011 sLAr Electronics Meeting - M. Riva
45
Experimental Set-up Zoom of the magnet gap at the INFN-LASA test facility Several values of magnetic field have been used to test the transformer: Bstaz=[789, 1295 , 1533, 1987, 2247 e 2591] Gauss. The external Bstaz influenced the normal operation in grater way when approaching to the saturation December 6, 2011 sLAr Electronics Meeting - M. Riva
46
Transformer behavior in stationary Magnetic Field
11/16/2011 46 Bstat. 789 Gauss Bstat Gauss orange = primary winding voltage blue = secondary winding voltage magenta = primary winding current green = snubber current (proportional to the switching losses). December 6, 2011 sLAr Electronics Meeting - M. Riva
47
Soft ferromagnetic materials for enhanced inductor cores
Optimization of the inductor core material for DC-DC switching power supplies Need of high of reliability magnetic cores of devices for extreme condition environments: High immunity to radiations High magnetization field and low coercive field High Br Low Hc Higher switching frequencies of the DC-DC converters Smaller dimensions of the inductors December 6, 2011 sLAr Electronics Meeting - M. Riva
48
FeSi compound Better high-frequency inductor core performance
Avoidance of magnetostriction phenomena Increase anisotropy Enhanced soft magnetic properties Specific activities are addressed to obtain a ferromagnetic nucleus able to produce high magnetic field with limited current stimulations. The base elements consist in a mixture of Fe and Si powders blended in precise ratio (percentage of organic additives, and blending methodology are key points) in order to make a ferromagnetic compound injection moulded in test sample. Starting from power Composition: Fe-6.8%Si Grain size: micron December 6, 2011 sLAr Electronics Meeting - M. Riva
49
Fabbrication process Metal Injection Moulding (MIM)
FeSi powder + polymer binder (“green” material) Debinding at 600°C Sintering at 1260°C December 6, 2011 sLAr Electronics Meeting - M. Riva
50
Challanges Cold ductility of such material makes its manufacture hard;
Use of a hydrogen atmosphere to avoid Fe oxidation during sintering; Hard and time-expensive recipe tuning; MIM parameters set: temperature of the material, of the cylinder and mould, pressure of injection, hold pressure, injection speed and screw feeding speed, time for the injection, time for hold pressure, time of cooling. December 6, 2011 sLAr Electronics Meeting - M. Riva
51
Prototype radiation tests
The prototype has been exposed to a dose of 5 kGy At a dose rate conditions of 100 Gy/h, during 2 days of exposure in the 24 hours December 6, 2011 sLAr Electronics Meeting - M. Riva
52
Preliminary Results I Initial local fusion of the polymeric component and a less crystallinity December 6, 2011 sLAr Electronics Meeting - M. Riva
53
Preliminary Results II
Detail of the polymeric ageing December 6, 2011 sLAr Electronics Meeting - M. Riva
54
The APOLLO proposal – Rad-hard devices
Seeking for power COTS MOSFETs radiation tolerant up to 10kGy and 1014/(s ∙ cm2) neutrons and protons: many components, with Vd ranging from 30V to 200V and polarized in various configurations, were tested at the 60Co g ray source in the ENEA center of Casaccia, near Roma same components were tested with a heavy ion beam, 75Br at 155MeV, at INFN Laboratori Nazionali del Sud in Catania within the end of the year same components will be tested under neutrons, at the Casaccia nuclear reactor Tapiro, and under protons, at INFN LNS Seeking for COTS controllers and FPGA radiation tolerant: first irradiation was performed under 216MeV proton beam in Boston, at Massachusetts General Hospital facility, using some of devices irradiated in Italy. Other irradiation campaigns are planned at the same facilities in the next months Results are still preliminary and under analysis. Other irradiation campaigns are necessary in order to select good devices. December 6, 2011 sLAr Electronics Meeting - M. Riva
55
Circuit set-up for g tests
Four parallel tests: Vdd=0 and Vgg=const. (80%Vgg,nom) sensitivity to the oxide bias Vgg=0 and Vdd=const. (80%Vdd,nom) sensitivity of the bulk (junction) of the device Vdd=80%Vdd,nom and Vgg switching sensitivity to the dynamic gate bias three leads shorted reference condition Vgg=const. Vdd=const. switching shorted December 6, 2011 sLAr Electronics Meeting - M. Riva
56
Switching condition effect during radiation - 30V MOSFETs –
Prossima: Oxide damage December 6, 2011 sLAr Electronics Meeting - M. Riva
57
Switching condition effect during radiation - 200V MOSFETs –
Different manufacturers Device B1 December 6, 2011 sLAr Electronics Meeting - M. Riva
58
Asym./Sym. Switching Comparison
Prossima: DIFFERENT MANUFACTURERS December 6, 2011 sLAr Electronics Meeting - M. Riva
59
Susceptibility to dose rate - 40Gy/h vs. 10Gy/h -
Prossima: DIFFERENT MANUFACTURERS December 6, 2011 sLAr Electronics Meeting - M. Riva
60
VTH SiC JFETs Prossima: DIFFERENT MANUFACTURERS December 6, 2011
sLAr Electronics Meeting - M. Riva
61
Ron SiC - SiC JFETs - Prossima: DIFFERENT MANUFACTURERS
December 6, 2011 sLAr Electronics Meeting - M. Riva
62
Combined effects: g rays and Heavy Ions
Devices under test: 30V STP80NF03L-04 30V LR7843 200V IRF630 For each type of device 20 samples were tested, 5 for each dose value (g rays at the ENEA Calliope Test Facility) Measurements : Breakdown VGS=-10V Threshold VDS=5V ON VGS=10V Gate VDS=10V Used doses: I Gray II Gray III Gray IV Gray December 6, 2011 sLAr Electronics Meeting - M. Riva
63
The SEE experimental set-up
The current pulses The IGSS evolution during irradiation The device is in “OFF” state and biased at constant VDS and VGS voltages Cg Cd 50 W 1 MW Vgs Impacting Ion DUT Vds Drain P + N _ Gate Source Body Parameter Analyzer Fast Sampling Oscilloscope December 6, 2011 sLAr Electronics Meeting - M. Riva
64
The SEE experimental results
200 V Mosfet: IRF630 Device TID Bias Conditions during Irradiation Drain Damage Gate Damage D21 0Gy Vds=20V-110V vgs=-2V Vds=100V-110V D06 1600Gy Vds=20V-70V vgs=-2V Vds=60V-70V D10 3200Gy Vds=20V-50V vgs=-6V Vds=40V-50V D16 5600Gy Vds=45V-50V Vds=40V-45V D17 9600Gy Vds=20V-45V vgs=-6V The increase of the ϒ-dose causes a reduction of the critical bias condition at which drain and gate damages appear December 6, 2011 sLAr Electronics Meeting - M. Riva
65
MOSFETs Exposed to Protons
Only 200V MOSFETs (IRF 630, samples from two different manufacturers) were exposed Proton energy: 216 MeV (facility at Massachusetts General Hospital, Boston) Ionizing Dose: < 30 Krads An “absolute” cross section will require the knowledge of the area of the MOSFET die which is unknown. The results are still preliminary. December 6, 2011 sLAr Electronics Meeting - M. Riva
66
MOSFETs Exposed to Protons
The number of SEB events recorded at each VDS was small less then 30 events for the ST less than 150 events for the IR devices Large statistical errors affect the measurements The cross section at VDS = 150V (“de-rated” operating voltage) can not be properly estimated Dependence from manufacturer “Knee” not well defined To effectively qualify the devices for 10 years of operation at Hi-LHC, the cross section has to be of the order of 10-17/ cm2, which puts the failure rate at <1 for 10 years of operation. Proton irradiation campaigns with increased fluences and more samples are planned. Work still in progress … December 6, 2011 sLAr Electronics Meeting - M. Riva
67
GaN Devices for fast switching
High frequency, high voltage ratio PoL criticalities: They must operate at low duty cycle (high voltage ratio); The switching period is short and operations are achievable only with fast switching commutations; GaN devices have the potential to switch ON-OFF in the MHz range (related to the driving capability and the assembly techniques) National Semiconductor 180W 1/8th Brick, Fully Regulated Converter December 6, 2011 sLAr Electronics Meeting - M. Riva
68
Studies on GaN Devices The tests adopt 40V and 200V GaN devices by EPC; Some problems in driving and prepare the test circuit (soldering the components) Electrical Characterizations are in progress Air bubbles X-rays for checking the solder quality December 6, 2011 sLAr Electronics Meeting - M. Riva
69
Preliminary electrical charcterization
EPC GaN MOSFET Preliminary electrical charcterization VDC vc DRIVER DUT L VCC + C1 iDUT Measured DUT voltage and current during switching intervals Rshunt = 85 mW UGS [1V/div] UDS [20V/div] -IDS [1A/div] Time [10ns/div] UGS [1V/div] UDS [20V/div] -IDS [1A/div] -poff(t) Time [10ns/div] Turn on Vcc = 100V, IDS = 0A Turn off Vcc = 100V, IDS = 5A December 6, 2011 sLAr Electronics Meeting - M. Riva
70
Conclusion Distributed Power Architecture has been proposed
Main converter (SILC topology) Point of Load converter (IBDV topology) Proper Magnetic Devices Design Power Planar Transformer (new magnetic material) Inductor in air Thermal Design Critical selection of components to proper withstand radiation Controller, Driver and Isolator FPGA for overall monitoring MOSFETS MOSFETS, both for MC and PoL have been selected and tested Gamma ray Heavy ions Protons Some results are encouraging, however more systematic validation is on-going Novel devices based on SiC and GaN, are also under investigation December 6, 2011 sLAr Electronics Meeting - M. Riva
71
Future Activities Update the design of the MC and realize a new prototype; Investigate the use of PoL made by CERN (F. Faccio) for high current loads; Test the IBVD PoL converter directly on the FEBs; Propose/Find radiation tolerant controllers Selection of PWM Custom made controller by using Analog Devices or FPGAs December 6, 2011 sLAr Electronics Meeting - M. Riva
72
Schematic of the Single Module (1.5 kW)
Dual-threshold current controller used to manage the capacitor charge and over load protection Auxiliary Power Supply for start-up and under voltage protection 1.5 kW SILC Power Converter Input voltage 280 V Output voltage (MC) 12 V Maximum power (MC) 1.5 kW Switching frequency (MC) 100 kHz Output voltage (AUX) V1,V2,V3=12 V V4=5 V Maximum power (AUX) 20 W Switching frequency (AUX) 200 kHz Auxiliary Power Converter December 6, 2011 sLAr Electronics Meeting - M. Riva
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.