1 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 1 Conceptpower Modular 80 and 100kVA THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT IT

2 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 2 Unique Power Protection Concept (PPC) 6 Key-Features at a Glance Modularity Redundancy Scalability Environmentally Friendly Serviceability Manageability

3 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 3 Conceptpower TM Modular First and unique hot swappable 3phase double conversion (VFI) UPS modular design 2 possible power ranges: 80 and 100kVA Modularity Welcome to the future of power protection Batt. Charge r Static Bypass Rect. Boost. Inverter Load

4 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 4 Conceptpower TM Module Front view 80-100kVA Passive module includes: Input filter Output filter Booster coils Static By-pass Active module includes: Rectifier & Booster Battery charger Inverter µProcessor control board

5 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 5 Conceptpower TM Module Front view 80-100kVA Dry contacts NC/NO, D25P/F connection EPO, Gen-on, Batt.temp.connector LCD Display Panel connector Module Interface connector Smart port RS232 By-pass line fuses ComBus Module to Module

6 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 6 Conceptpower TM Module Weight of the passive module 80-100 kVA: 55-60 Kg Size of the UPS module: 667x412x834mm (WxHxD) Weight of the active module 80-100 kVA: 55-60 Kg Size of the UPS module: 667x412x834mm (WxHxD) Rear view 80-100kVA

7 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 7 Conceptpower TM Module Inside view 80-100kVA Inverter Booster Batt. Charger DC Cap. µ Control board By-pass Input LC FIlter Output LC Filter

8 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 8 Conceptpower TM Modular Welcome to the future of power protection Power modules: 80-100 kVA Upgrade frame 300 kVA

9 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 9 Conceptpower TM Modular UPGRADE FRAME Power modules: 80-100kVA Limited up to 10 modules in parallel (> 10 modules on request) Distribution section for the max. capacity (300kVA) Space saving, 300kVA in 1.22 sqm. No single point of failure UPS – module 2 Distribution 300kVA UPS – module 3 UPS – module 1

10 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 10 Conceptpower TM Modular UPGRADE FRAME DISTRIBUTION 300KVA Modules output disconnects Centralized Maintenance By-pass Centralized SNMP Slot (Multidrop). DPA extension bus RS232, PFC, EPO

11 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 11 Conceptpower TM Modular - Scalability Optimized capital investment by extending your power protection capacity at a pace that fits your business on demand Scalable performance of the power capacity and runtime by simply adding independent UPS or battery increments Upgrade Frame (Vertical Scalability) (floor-saving-frame) UPS – module 2 Distribution 300kVA UPS – module 3 UPS – module 1

12 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 12 No additional hardware for harmonic reduction is required Conceptpower TM Modular Environmentally Friendly 1997/06/03 10:54:36 5ms/div (5ms/div) NORM:200kS/s Input Voltage Input Current Sinewave input current (THD=7-9%) Input PF=0.98 in a standard version This means: Smaller cables size and lower losses Smaller fuses or Circuit Breakers (no malfunction and false tripping) No separate phase compensation required No extra heating of transformer and generators oversized 6-pulse rectifier 12-pulse rectifier

13 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 13 The total annual operating costs for a Newave UPS can be >40% less compared to those for a previous generation Conceptpower TM Modular Environmentally Friendly Highest double-conversion efficiency ESIS (Energy Saving Inverter Switching) up to 95% in on- line, double conversion mode Load dependent audible noise Wide input frequency windows (35-70Hz) Low weight (3x100kVA: 700kg) Compact size (3x100kVA: 1.22 sqm)

14 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 14 Conceptpower TM Modular Environmentally Friendly Product positioning Case 1: configuration required 2x200kVA redundant Legacy 2x200kVA UPS configuration 6 Pulse UPS (2x1.24 sqm) 12 Pulse rectifier (2x0.55 sqm) Harmonic Filter& PFC (2x0.55 sqm) Total footprint required: 4.68 sqm Total weight: >3500Kg UPS –2UPS –1 12 Pulse Harmonic Filter & PFC Harmonic Filter & PFC UPS – module 2 Distributi on 300kVA UPS – module 3 UPS – module 1 Modular 3x100kVA Total footprint required: 1.22 sqm Total weight: 700Kg Distrib ution 200kV A UPS – 1 Distrib ution 200kV A UPS – 2 MAXI 2x200kVA Total footprint required: 1.8 sqm Total weight: 1280Kg

15 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 15 Conceptpower TM Modular Environmentally Friendly Product positioning Case 2: configuration required 2x500kVA redundant UPS – modul e 2 Distrib ution 300kV A UPS – modul e 3 UPS – modul e 1 Modular 6x100kVA Total footprint required: 2.44 sqm Total weight: 1400Kg UPS – modul e 5 Distrib ution 300kV A UPS – modul e 6 UPS – modul e 4 Distri butio n 250k VA UPS –1 MAXI 3x250kVA Total footprint required: 2.7 sqm Total weight: 1980Kg Distri butio n 250k VA UPS –2 Distri butio n 250k VA UPS –3 Legacy 2x500kVA UPS configuration 12 Pulse UPS (2x2.1 sqm) Harmonic Filter& PFC (2x0.88 sqm) Total footprint required: 5.96 sqm Total weight: >6200Kg UPS –1 & 12 Pulse Harmonic Filter & PFC UPS –2 & 12 Pulse Harmonic Filter & PFC

16 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 16 Battery cost saving Flexible Battery Management (FBM) Variable DC-voltage enabling the use of battery blocks (40-50 blocks of 12VDC) Wide input voltage windows (-23%/+15% @100% load) (-30%/+15% @<80% load) (-40%/+15% @<60% load) Less need for battery operation Automatic battery test with algorithm CPU controlled Early warning in case of battery fault Temperature compensation Increases battery lifetime Ripple free through battery charger Longer battery life time Legacy UPS Conceptpower UPS

17 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 17 Modular and hot-swappable design means minimizing service and maintenance cost and Reduction of MTTR, maximize your power protection availability Front access only No needs for skilled personnel on site No need of spares, just modules Conceptpower TM Modular Serviceability

18 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 18 Redundant Power Management Display advances the Power Protection Manageability Common data execution functions for parallel systems on redundant parallel PMD’s. The complete parallel system may be managed by any one of the parallel PMD’s. PMD consists of mimic diagram for system status, push buttons for single module and parallel system control and LCD for monitoring, event logs and diagnosis. Conceptpower TM Modular Manageability

19 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 19 ALARM LINE 2 LINE 1 BATTERY BY PASS INV RESETENTER LCD Display ON / OFF Conceptpower TM Module Display Most important information available at first glance

20 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 20 Remote Signalling Panel (RSP) For Status and Alarm Remote Indications Wavemon (CD) For Automatic Server shutdown and Monitoring. Cross Platform shutdown available SNMP-card or Box for connection of UPS in Network Management systems Conceptpower TM Modular Remote Control and Shutdown

21 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 21 1. Optimize capital investment and available space Pay-as-you-grow solution lowers your capital costs and increases utilization rates, while innovative rack-based technology frees up space previously needed for infrastructure support. 2. Adapt to ever-changing power requirements No need to abandon previous investment when power density needs increase or if physically moving your data centre. Adapt to changing wattage requirements in your racks with single- or multi-branch rack-mount power distribution units. 3. Accelerate speed of deployment Electrical and physical modularity allows for rapid installation with minimal engineering. 4. Lower the cost of service contracts Simplicity of system design and intelligent modular parts lessen the dependency on expensive service contracts. 5. Increase availability Specifically engineered to deliver higher availability through proactively designed, building block architecture and reduced MTTR 10 reasons for buying Conceptpower TM Modular

22 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 22 10 reasons for buying Conceptpower TM Modular 6. Decrease mean-time-to-recovery (MTTR) Compartmentalize potential failures with system components consisting of intelligent, maintainable modules for quick fault recovery. 7. Plan for a power density that is increasing and unpredictable Eliminate hot spots in your data centre caused by higher power densities by targeting availability where you need it most. 8. Minimize points of failure between the UPS and the critical load Move redundancy closer to the load and prevent the majority of failures that cause critical load downtime. 9. Minimize human error Simplicity of design and intelligent modules increase system availability by mitigating human error: the number one cause of critical load downtime. 10. Decrease the operating costs With efficiency up to 95% (double conversion mode), the operating costs for a Conceptpower modular UPS can be >40% less compared to those for a previous generation

23 Newave SA, Switzerland – info@newave.ch - www.newaveups.com 28/02/2006 23 Swiss Quality INNOVATION INNOVATION SUPPORT SUPPORT QUALITY QUALITY Power Protection Leader Through Innovation TO PROTECT YOUR MISSION CRITICAL APPLICATIONS