Download presentation
Presentation is loading. Please wait.
Published bySheila Goodwin Modified over 9 years ago
1
X-ray Timing and Polarization mission & instrumentation DONG Yongwei Center for Particle Astrophysics Institute of High Energy Physics, Chinese Academy of Sciences
2
XTP Scientific objectives Scientific Problems One Singularity (BH), Two Stars (NS and magnetar), Three Extremes (gravity, density, magnetism) The effective area of focusing telescope has been confirmed to be the breakthrough capability of the merged mission. The unique polarization measurement capability has been selected as the distinguishing feature. XTP will open a new window using its powerful capability of polarization observation.
3
XTP payload configuration 3 FL: 4.5m, FoV 16’,0.5~15keV 5000cm 2 @2~6keV FL: 5.5m, FoV 16’,1~30keV 4000cm 2 @2~6keV, 300cm 2 @30keV 1°×1°,8-100 keV 2500 cm 2
4
Summary of focal payload HFALFA Optics Mirror Quasi-Wolter I, nested,Multi-layer Shell substrate : Al foil or slumped glass Quasi-Wolter I, nested Shell substrate : Al foil or slumped glass Focal length5.5m4.5m FOV16’ HPD2’ Energy range1~30keV0.5~15keV Effective Area 4000cm2@2~6keV 300cm2@30keV 5000cm2@2~6keV Units 5(3GEM-TPC+CZT, 2SDD/DEPFET) 10 Focal plane detector GEM-TPC(top)+CZT(focal point): CZT(1mm*1mm*1mm) : 16*16 SPD(or DEPFET): 10×10 pixels, 1mm×1mm×0.5mm SDD(or DEPFET): 10×10 pixels 1mm×1mm×0.5mm Energy resolution CZT : 600 eV@5.9 keV SDD/DEPFET : 150eV@5.9keV 150eV@5.9keV
5
Nested quasi-wolter I type Mirror length 100 mm Thickness 0.2 mm F/D ~ 10 Inner: W/Si; outer Ir Slumped Glass/ Al foil X-ray optics
6
Focal plane detectors SDD/SPD, or DePFET(MPE) 7 SDD detectors. FWHM=160eV@5.9keVFWHM=160eV@5.9keV at room temp. 100-pixel Si-PIN detectors. FWHM=1.1keV@60keVFWHM=1.1keV@60keV at room temp.
7
Polarization meas. using GEM-TPC Cross-section of photoelectric effect
8
Transmissive design of GEM-TPC @Tsinghua University Focal plane Focused beam
9
High energy X-ray Collimating Array Sketch map of One HCA module CZT detector is applied. The collimator is made using Lithographie - Galanoformung - Abformung (LIGA) technique. Nickel, hole size 170*170μm, Grid thickness 30μm, Height 0.6mm
10
Wide Field Camera The WFC is to monitor the transient X-ray sources and to localize them with an accuracy of 5 arcmin. With the slew of platform, other instruments will be guided to make follow-up observations.
11
XTP area and background XTP effective area
12
Launcher LM-3C, 2 boosters. 12
13
LM-3C launch capability The launch capability of the LM-3C for LEO mission into a 200 km circular orbit with an inclination of 28.5 deg is 9,100 kg. 550km & 28.5 deg ~ 6 t. Altitude easy to be changed. Inclination angle NOT! 13 LM-3C launch capa. for GTO orbit
14
XTP orbit Basic para. Altitude 550 km Inclination angle 28 degree (14 degree as backup). It depends on the particle background, particle flux, SAA crossing time, earth occulation, ground stations
15
Miscellaneous Mass: <3200 kg (satellite); ~1100kg (payload) Power: 1300W (platform); 1000W(payload) Launch time: ~2020 Lifetime: 5 years (expected, 10 years) XTP has been selected as a background project by the Strategic Pioneer Program (SPP) on Space Science of the Chinese Academy of Sciences. X band data: rely satellite or international collaboration (if the inclination angle is too small) Focal plane detectors & collimating detectors Thanks!