TDA100D Contents 1 Target Customer
2 Selling Points 3 Improvement from current KX-TDA100 4 System Configuration 5 Compatibility between TDA100D and TDA/TDE 6 New PCMC We explain about the TDA100D with the following contents.
2
1. Target Customer First there is the Target Customer section.
3
Built-in 4 Digital PT Ports
1. Target Customer Solutions >> Small - Mid Size Office Target : SLTs MPR MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card DLC4 New 24/16 SLC card for 120 SLTs Built-in 4 Digital PT Ports Digital PT for manager or operator This page shows a target customer of a small to middle sized office. TDA100D has built-in support for 4DLC ports for Digital PTs without the need for options. So even if SLTs are used for employees, a manager or operator can use Digital PTs. Single Line Telephone for employees Even if SLTs are mainly used, a few Digital PTs are required for manager or operator. New TDA100D has built-in support for 4 DLC ports for these Digital PTs. 3
4
Built-in 4 Digital PT Ports
1. Target Customer Solutions >> Warehouse, Car dealer, Factory... With System Wireless Retail Stores Warehouses MPR DLC4 Large Residences Automotive Dealerships Built-in 4 Digital PT Ports Schools Factories This page shows a target customer of a warehouse, car dealer and so on. TDA100D has built-in support for 4DLC ports for wireless systems without the need for options. And wireless systems give you anytime, anywhere access. Wireless system give you anytime, anywhere access. New TDA100D supports 4 DLC ports for these wireless systems without the need for options. 4
5
Built-in 4 Digital PT Ports
1. Target Customer Solutions >> Small Hotel Target : Rooms Built-in 4 Digital PT Ports MPR System Wireless for staff DLC4 MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card 232C Serial New 24/16 SLC card for 50 SLTs EXT.(room)101 call detail This page shows a target customer of a small hotel. TDA100D has built-in support for 4DLC ports for Digital PTs and system wireless without the need for options. Also new SLC cards have a message waiting lamp control function. So staff can use system wireless, front desk can use digital PTs, and guests can use SLTs in guest rooms. In addition, by using CA Call Accounting, it is easy to make a call billing per room. Digital PT for front desk KX-T7710 for each room CA Call Accounting for simple billing New TDA100D has built-in support for 4 DLC ports for DPTs and system wireless without the need for options. If you use CA Call Accounting (FOC), it is easy to make a call billing per room. 5
6
2. Selling Points
7
2. Selling Points Simple Installation Built-in 【Current TDA100】
Solutions >> Simple Installation 【Current TDA100】 【New TDA100D】 Built-in PSU PSU DLC DLC4 For Wireless System For DPITS Programming For Future expansion Provide reasonable wireless system with Built-in DLC and Entry DECT terminal. Built-in DLC4 can be used for DPITS programming without additional DLC. No need for PSU type selection. Built-in New PSU enables future expansion. New The current TDA100 does not include either the PSU or DLC cards. The new model TDA100D includes built-in PSU and DLC4. So TDA100D gives you simple installation, such as installation of system wireless, and DPITS programming without the need for an additional DLC. In addition it is not necessary to select PSU type even when the system capacity is expanded. Programming DPITS Before NO Need NO Need Over-Capacity PSU for the Future Expansion. New Built-in! CSIF Card DLC Card DLC Card PSU-S SLT Entry DECT 7
8
8-port base analogue CO card KX-TDA1180
2. Selling Points Solutions >> Flexible Expansion New Analog CO Cards & New 24/16 port SLC Cards save slots and provide expanded capacity New 24/16 port SLC Card New Analog CO Card Built-in both Caller ID Function and Message Waiting Lamp Control Built-in Caller ID Function 【Current】 【New】 【Current】 【New】 Need 2 types of card (CSLC & MSLC) Only need One card (MCSLC24/16) Need one LCOT16 + 2 CID card Only need two cards (CLCOT8 + CLCOT8E) New SLC cards and new analog CO cards save slots and provide expanded capacity. New SLC cards have built-in caller ID function and message waiting lamp control. So if you use both caller-ID and message waiting lamp, only one MCSLC card needs to be installed. New analog CO cards have built-in caller-ID function. So if you use caller-ID function, only one CLCOT card needs to be installed. . 8-port expansion daughter card KX-TDA1186 8-port base analogue CO card KX-TDA1180 8
9
from small to mid-sized office Targeting between 24 to 120 SLT
2. Selling Points Solutions >> Wide Cover from Upper TES824 to TDA200 Range 【New】 【Current 】 from small to mid-sized office SLT 8 - 64SLT (24SLT× 5 + Built-in PSU) (16SLT x 4 + OPB + PSU-S) Plus more 8-DPT or Wireless 16 24 64 96 120 128 Max SLT Capacity TDA100D Range Targeting between 24 to 120 SLT PSU/DLC4 Built-in PSU-M TDA200 Range TDA200 TDA100D can cover up to 120pcs SLT with 5pcs 24SLC card. In addition it can install 8pcs DPT or wireless without the need for options. So TDA100D can cover from upper TES824 to TDA200 range without changing PSU and MEC cards. TDA 100 TDA100 Range TDA 100 PSU-S TES824 Range PSU-M MEC Card 9
10
3. Improvements from Current KX-TDA100
11
3. Improvements from Current KX-TDA100
Solutions >> Feature Differnce from Current KX-TDA100 V5* More SLT Capacity Built-in More Flexibility < New TDA100D > 7 New PSU (Built-in) Free slot Free slot Free slot Free slot Free slot Free slot Free slot MPR 1. System Capacity SLT port without MEC and Power Supply Unit replacement 2. New 24/16 port SLC card with built-in Caller ID* and Message Waiting Lamp Control* 3. New Analog CO card with built-in Caller ID 8 ports by default and additional 8 ports expandability in same slot by option for easy expandability. 4. New MPR card with built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F 5. New Shelf with built-in Power Supply Unit 6. SMDR Call storage – 2500 calls * PBX software feature is the same as KX-TDA100/200 MPR version 5. * Message waiting specification is similar to current MSLC16. * Caller ID specification is similar to current CSLC16. * Provide new PC Maintenance Console dedicated for TDA100D (separated from current UPCMC) * All kind of card will be able to install to Slot 7 DLC4 USB Serial I/F < Current TDA100 > 1 2 3 4 5 6 PSU-S/M (Option) Free slot Free slot Free slot Free slot Free slot Free slot MPR This page explains the feature differences from the current TDA100. The number of SLTs is up to 120 without MEC card and PSU replacement. It can install new 24 and 16 port SLC cards with caller-ID and message waiting lamp control. It can install new analog CO cards with caller-ID. New MPR cards have built-in DLC4 and serial I/F. The new shelf has built-in PSU. SMDR call storage is up to 2500 calls. The number of free slots is up to 7. Serial I/F USB 11
12
w/o MEC (Max. No. of User is 64)
3. Improvements from Current KX-TDA100 Solutions >> System Capacity Simpler installation to expand system capacity than the current TDA100. No additional MEC or PSU is required for Max. configuration (including 128 SLT or 152 DPT/IP-PT). - Memory Expansion Card is NOT required for more than 64 extensions. - No need to replace PSU for more than 64 extensions. Model TDA100 (reference) TDA100D MEC w/o MEC (Max. No. of User is 64) w/MEC Regardless MEC PSU PSU-S PSU-M New PSU (Built-in) Extension System Total 64 96 160 176 (*) MPR DPT(DXDP) 4 (8) Free Slot IP-PT 112 SLT 128 96(96) Total 168 Trunk 120 126 (**) LCOT BRI 96(48BRI) 112(56BRI) PRI 120(4PRI) IP-GW Maximum 126 trunks are available with one PRI LCOT. Maximum 176 extensions are available without MEC and replace PSU. (*) TDA100D: In case of PT configuration : Max. 176 extensions with 104 DPT(DXDP) + 48 IP-PT + 24SLT (**) Max. 126 trunks with one PRI LCOT. When installing T1, E1, PRI30, or PRI23 cards, make sure that the number of these cards X 2 + the number of other cards (including IP-GW4E cards) does not exceed 8. 12
13
3. Improvements from Current KX-TDA100
Solutions >> New SLC24/16 Card (MCSLC24/MCSLC16) with CID and MW lamp Provide New 24/16 ports SLT interface card with built-in Caller ID and Message Waiting Lamp control. With this card, users can expand the number of SLT extensions up to 128. (Cannot use DLC4 on MPR cards.) Configuration Example Slot TDA100 w/PSU-M TDA100D w/new PSU MPR - 4DPT I/F 1 DHLC8 New MCSLC24/MCSLC16 New MCSLC24 2 SLC16 3 4 5 New MCSLC16 6 (Trunk) 7 (OPB3) SLT Total 72 120 128 TDA100D supports new SLC24/16 cards with caller-ID and message waiting lamp control, and new SLC24/16 cards are called as MCSLC24/16. If you use 4pcs MCSLC24 and 2pcs MCSLC16, you can use 128pcs SLTs. But then you cannot use DLC4 on MPR, because of the limitation of load figure. - 24/16 SLT ports per card - Max. 5 MCSLC24/Max.7 MCLSC16 cards per PBX - 2 Power Failure Transfer (PFT) ports - Built-in Caller ID (FSK) & Message Waiting Lamp Control * Caller ID specification is similar to current CSLC16. * Message waiting Lamp specification is similar to current MSLC16. * No self diagnostic function by PCMC Specifications 13
14
3. Improvements from Current KX-TDA100
Solutions >> New 8-port Analog CO Card with 8-port expansion Provide New 8-port Analog CO line interface card with 8-port expansion board. New card will support CID functions as a standard. Accordingly, this card will provide flexible system expansion capability and low-cost installation for users that require CID. Built-in Caller ID Circuit Built-in Caller ID circuit 2 PFT ports Mount to Base board 8–port expansion daughter card TDA100D supports new 8-port analog CO cards with caller-ID. And 8-port expansion daughter cards can be mounted on base cards without using slots. Accordingly, these cards will provide flexible system expansion capability. 8-port base LCOT card - 8 analog trunk ports per card - Expand up to 16 ports with 8 ports daughter card - 2 power failure transfer (PFT) ports for 8 / 16 ports - Built-in Caller ID - Pay tone detection is not available - User-supplied Amphenol connector I/F Specifications 14
15
3. Improvements from Current KX-TDA100
Solutions >> New MPR Card for TDA100D Built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F for easy and cost effective installation. Users who mainly use SLT do not need to purchase DHLC cards at the initial installation. In addition, - Expand SRAM capacity for supporting SMDR data registration up to 2500 calls - I/F for two Music On Hold input ports and two External Pager output connectors will be changed to a RJ45. - Serial Interface (RS-232C) port will be mounted on MPR card Note: 1. System will not work correctly when a new MPR card is installed to an existing TDA/TDE shelf. But no safety issues will occur. 2. Exchange cable, from MOH/Pager mini jack to RJ45, will not be provided. New TDA100D MPR TDA100 MPR RJ11 For DLC 4 Ports TDA100D has a new MPR card. The new MPR card has built-in DLC4 for installing DPIT or wireless systems, and serial I/F for outputting SMDR data. In addition, the I/F for Music On Hold and External Pager connectors are changed to RJ45. SCALE-UP RJ45 For MOH x2 & Pager x2 RS-232C For SMDR SIDE VIEW FRONT VIEW FRONT VIEW 15
16
System Total (DPT, CS and SLC card)
3. Improvements from Current KX-TDA100 Solutions >> New Shelf and Power Supply Unit for TDA100D A new shelf with built-in Power Supply Unit (PSU) is provided. New power supply supports up to 128 load figure including max.104 for DPT/CS (see below). Therefore, users do not need to replace PSU when expanding the system. In this respect, TDA100D will cover TDA200 user range. Note: 1. Power supply and Shelf will be a new design, so there will be some incompatibility with the existing TDA/TDE series. 2. Current PSU-S/M (TDA0108/TDA0104) will not be used for TDA100D. 3. System will not work correctly when existing TDA/TDE MPR cards are installed in to a new TDA100D shelf. In this case, no safety issues will occur. Calculate the load figure from the type of equipment to be connected. Type Maximum Load Figure System Total (DPT, CS and SLC card) 128 DPT and CS 104 New PSU-S (Built-in) TDA100D has a new shelf with a built-in Power Supply Unit. The new PSU supports up to 128 load figure, so TDA100D will cover the current TDA200 range without needing PSU replacement. As previously explained, if 128pcs of SLT are used, neither DPT or CS can be used. Add 7th Slot Type Load Figure PT DPT (DT300, T7600) 1 IP-PT SLT card New MCSLC24 24 New MCSLC16 16 CS 2-4ch CS 4 8ch CS 8 New Shelf and Power Supply 16
17
4. System Configuration
18
Max. Number of card/unit Max. Number of card/unit
4. System Configuration Solutions >> Optional Card / Unit <Option> Max. Number of card/unit TDA100 TDA200 TDA100D Trunk Total 6 (*1) 8 (*1) 7 (*1) LCOT4 LCOT8 6 8 7 LCOT16 CLCOT8 - CLCOT8E DID8 E&M8 BRI4 BRI8 T1 E1 4 PRI30 PRI23 IP-GW4 IP-GW4E IP-GW16 <Option> Max. Number of card/unit TDA100 TDA200 TDA100D Ext Total 6 8 7 4DPT I/F on MPR - 1 DLC8 DLC16 IP-EXT16 DHLC8 SLC8 SLC16 CSLC16 MSLC16 New MCSLC24 5 New MCSLC16 CSIF4 4 CSIF8 CTI-LINK OPB3 MSG4 ESVM2 ESVM4 DPH4 DPH2 EIO4 ECHO16 2 TDA100D can install a maximum of 7 trunk cards or 7 extension cards. Current DHLC8, SLC8, SLC16, CSLC16 and MSLC16 cards will not be supported. A maximum 128pcs PS can be installed, which is the same as the current TDA100/200. CS CS(2-4ch) 32 26 CS(8ch) 16 13 (*1) One T1, E1, PRI30, PRI23, or IP-GW4 card counts as 2 cards. 18
19
4. System Configuration SLT Max. Capacity Comparison
Solutions >> SLT Max. Capacity Comparison TDA100 TDA200 TDA100D PSU-S PSU-M PSU-L New PSU Extension System Total 64 96 128 MPR DPT(DXDP) 4 (8 w/DXDP) Slot SLT 120 Analog CO 128 112 96 TDA100 w/ PSU-M & MEC TDA200 w/ PSU-M TDA100 w/ PSU-S 48 This is an analog CO and SLT capacity chart. The capacity of the TDA100D is greater than the current TDA100 with PSU-M and MEC. In addition, the SLT capacity is the same as the current TDA200. Expanded SLT capacity 32 16 SLT 64 96 120 128 <CO and SLT capacity chart > 19
20
5. Compatibility between TDA100D and TDA/TDE
21
5. Compatibility between TDA100D and TDA/TDE
Solutions >> New Cards for existing TDA/TDE system Model Description TDE100/200 MPR V3 TDA100/200 MPR V5 MPR Software - MPR Software of TDA100D No MPR Card MPR card of TDA100D (w/ DLC4) Trunk Cards KX-TDA1180 8-Port Analogue Trunk Card with CID (CLCOT8) No (in future) KX-TDA1186 8-Port Analogue Trunk with Caller ID daughter Card (CLCOT8E) Extension Cards KX-TDA1178 24-Port Single Line Telephone Card w/ Caller ID & MW Lamp control (MCSLC24) KX-TDA1176 16-Port Single Line Telephone Card w/ Caller ID & MW Lamp control (MCSLC16) Power Supply Unit New S-Type Power Supply Unit (new PSU-S) All the new cards, PSU and software of the TDA100D cannot be used with the current TDA/TDE series. It is planned both the new trunk card and new extension card will both be able to be used with the TDE100/200 in future. 21
22
5. Compatibility between TDA100D and TDA/TDE
Solutions >> Existing Card for TDA100D (1/3) Model Description TDA100D MPR Software - MPR Software of TDA100/200 No Optional SD Memory Cards KX-TDA0820 SD Memory Card for Software Upgrade KX-TDA0920 SD Memory Card for Software Upgrade to Enhanced Version Yes(*1) MPR Card MPR card of TDA100/200 or TDE100/200 No(*2) MPR Option Card KX-TDA0105 Memory Expansion Card (MEC) No (*3) KX-TDA0196 Remote Card (RMT) Yes Trunk Cards KX-TDA0180 8-Port Analogue Trunk Card (LCOT8) KX-TDA0181 16-Port Analogue Trunk Card (LCOT16) KX-TDA0182 8-Port DID Card (DID8) KX-TDA0183 4-Port Analogue Trunk Card (LCOT4) KX-TDA0184 8-Port E & M Trunk Card (E&M8) KX-TDA0187 T-1 Trunk Card (T1) KX-TDA0188 E-1 Trunk Card (E1) KX-TDA0189 8-Port Caller ID/Pay Tone Card (CID/PAY8) KX-TDA0193 8-Port Caller ID Card (CID8) KX-TDA0284 4-Port BRI Card (BRI4) KX-TDA0288 8-Port BRI Card (BRI8) KX-TDA0290CE PRI Card (PRI30) KX-TDA0290 PRI Card (PRI23) KX-TDA0480 4-Channel VoIP Gateway Card (IP-GW4) KX-TDA0484 4-Channel VoIP Gateway Card (IP-GW4E) KX-TDA0490 16-Channel VoIP Gateway Card (IP-GW16) TDA100D cannot use the software of the current TDA100/200 or TDA0820, and the MPR card of the TDA100/200 or TDE100/200. On the other hand, all of the current trunk cards can be installed to the TDA100D. (*1): KX-TDA0920 will be updated before TDA100D released, (*2): Existing TDA/TDE MPR card will be able to install TDA100D KSU physically, but function will not work properly. (*3): DMPR support 2500 SMDR data registration, so that No MEC card support is needed 22
23
5. Compatibility between TDA100D and TDA/TDE
Solutions >> Existing Card for TDA100D (2/3) Model Description TDA100D Extension Cards KX-TDA0143 4 Cell Station Interface Card (CSIF4) Yes KX-TDA0144 8 Cell Station Interface Card (CSIF8) KX-TDA0170 8-Port Digital Hybrid Extension Card (DHLC8) No KX-TDA0171 8-Port Digital Extension Card (DLC8) Yes(*1) KX-TDA0172 16-Port Digital Extension Card (DLC16) KX-TDA0173 8-Port Single Line Telephone Extension Card (SLC8) KX-TDA0174 16-Port Single Line Telephone Extension Card (SLC16) KX-TDA0175 16-Port Single Line Telephone Card with MW Lamp (MCSLC16) KX-TDA0177 16-Port Single Line Telephone Card with Caller ID (CSLC16) KX-TDA0470 16-Channel VoIP Extension Card (IP-EXT16) Other Cards KX-TDA0161 4-Port Door phone Card (DPH4) KX-TDA0162 2-Port Door phone Card (German Type) (DPH2) KX-TDA0164 4-Port External Input/Output Card (EIO4) KX-TDA0166 16-Channel Echo Canceller Card (ECHO16) KX-TDA0168 Extension Caller ID Card (EXT-CID) KX-TDA0190 Optional 3-Slot Base Card (OPB3) KX-TDA0191 4-Channel Message Card (MSG4) KX-TDA0192 2-Channel Simplified Voice Message Card (ESVM2) KX-TDA0194 4-Channel Simplified Voice Message Card (ESVM4) KX- TDA0410 CTI Link Card (CTI-LINK) Current DHLC8, SLC8, SLC16, MCSLC16 and CSLC16 cards cannot be installed to the TDA100D. Current DLC8 and DLC16 cards can be installed to the TDA100D, but the software must be updated. In addition, the Extension caller ID card also cannot be installed. (*1): KX-TDA0171,0172 LPR Software will be updated before TDA100D released, so that when users use these existing cards for TDA100D, users must update to new software 23
24
5. Compatibility between TDA100D and TDA/TDE
Solutions >> Existing Card for TDA100D (3/3) Model Description TDA100D Power Supply Units (PSUs) KX-TDA0103 L-Type Power Supply Unit (PSU-L) No KX-TDA0104 M-Type Power Supply Unit (PSU-M) KX-TDA0108 S-Type Power Supply Unit (PSU-S) Cell Stations (CSs) 2.4GHz KX-TDA0141 2-Channel CS Using a DHLC/DLC Card for 2.4 GHz PS KX-TDA0142 3-Channel CS Using a CSIF Card for 2.4GHz PS KX-TDA0151 Yes KX-TDA0152 DECT KX-TDA0141CE 2-Channel CS Using a DHLC/DLC Card for DECT PS KX-TDA0142CE 4-Channel CS Using a CSIF Card for DECT PS KX-TDA0155CE KX-TDA0156CE KX-TDA0158CE 8-Channel CS Using a DHLC/DLC Card for DECT PS DECT 6.0 KX-T0155 2-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS KX-TDA0156 4-Channel CS Using a CSIF Card for DECT 6.0 PS KX-T0158 8-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS Proprietary Equipment KX-A228 S/M-type Back-up Battery Cable KX-A229 L-type Back-up Battery Cable KX- A258 Blank Slot Cover KX-T30865 Door Phone KX-T7765 TDA100D has a new PSU, so the current PSU-S/M/L cannot be used. TDA014x series Cell Station cannot be installed. And the A229 for L-type back-up battery cable cannot be used. 24
25
5. Compatibility between TDA100D and TDA/TDE
Solutions >> Terminal Compatibility for TDA100D (1/2) Model Description TDA100D DPT DT300 DT346 6Line-LCD, with Backlight, 12CO, USB, Bluetooth optional Yes Series DT343 3LIne-LCD, with Backlight, 12CO, USB, Bluetooth optional DT333 3Line-LCD, No Backlight DT321 1Line-LCD, 8CO DT390 DSS console T7600 T7636 6Line-LCD, with Backlight, 12CO, USB Optional T7633 3LIne-LCD, with Backlight, 12CO, USB Optional T7630 T7668 1Line-LCD T7667 1Line-LCD, No Backlight, 12CO T7665 1Line-LCD, No Backlight T7625 No-LCD T7640 T7500 series No T7400 series T7200 series This is the DPT compatibility for the TDA100D. T72xx, T74xx and T75xx series cannot be used with the TDA100D. 25
26
5. Compatibility between TDA100D and TDA/TDE
Solutions >> Terminal Compatibility for TDA100D (2/2) Model Description TDA100D APT T7700 series No T7300 series T7100 series T7000 series PT T7710 No-LCD, Message Lamp Yes PS DECT TCA155,TCA256,TCA355, CA175、TCA275, etc. DECT6.0 TD7685,TD7695, TD7996 2.4G TD7684,TD7694, etc. Voice Mail TVM200 TDA100D supports two VM system (12port/24ch) TVM50 TDA100D supports two VM system (3port/6ch) Note: There will be some differences between TDA100D and existing TDA/TDE series as follow. 1) SMDR and HOTEL information registration capacity will be increased up to 2500. 2) Broadcasting (Announcement to 31 members) will be activated without MEC. And no APT series devices can be used with the TDA100D. 26
27
6. New PCMC
28
6. New PCMC Dedicated PCMC for TDA100D
Solutions >> Dedicated PCMC for TDA100D "Multi-Site PBX Manager“ not supported The TDA100D has a dedicated PCMC. This PCMC does not support “Multi-Site PBX Manger”, and is displayed only as the “TDA100D” icon in the “New” window. On the other hand, a unified PCMC is prepared for the sales companies and dealers that already have an installed current unified PCMC. This unified PCMC version is V7 or later. Displayed only as the "TDA100D" icon in the "New" window. 28
29
End of Document