Presentation is loading. Please wait.

Presentation is loading. Please wait.

Proposed TDA Firmware Enhancements

Similar presentations


Presentation on theme: "Proposed TDA Firmware Enhancements"— Presentation transcript:

1 Proposed TDA Firmware Enhancements
       Feature                                Software version            Release date 1.    Digital Extra Device Port                1.1                        Available with launch of KX-TDA30                                                                                         Apr/May '04 for KX-TDA100/200                                                                                         2.    2 cell station card (KX-TDA0141)    1.1                        Available with launch of KX-TDA30                                                                                         Apr/May '04 for KX-TDA100/200 3.    IP Extension & Handset                 2.0                        Oct/Nov '04 for KX-TDA100/200                                                                                         Jan/Feb '05 for KX-TDA30 4.    Networking Enhancements            2.0                        Oct/Nov '04 for KX-TDA100/200 5.    CTI Enhancement                                                 Oct/Nov '04 for KX-TDA100/200 6.    Hotel Features                                                     Oct/Nov '04 for KX-TDA100/200                                                                                         Jan/Feb '05 for KX-TDA30

2 Initial Configuration
TDA200 TDA100 March/2003 TDA30 March/2004 Port Max. Trunk TDA200 128 Extension TDA100 64 TDA30 12 28 (SLT 24+DPT 24) Initial Configuration CO Extension DHLC-4 (SLT 4 + DPT4)

3 Revised after Sales Conference to accommodate changes that were possible.
This Ad will appear in Small Business Magazine. Note no further changes possible.

4 Revised after Sales Conference to accommodate changes that were possible.
This Ad will appear in newspaper adverts. Note no further changes possible.

5 Final Version of BPR Advert.
Note no further changes possible.

6 TDA30 - Doorphone (Max.1) - MSG (Max.2) - Ext.Caller ID (Max.1)
- Echo chancel (Max.1) - DLC-4 (Max.1) - SLC-4 (Max.1) - BRI-2 (Max.3) - LCOT-4 (Max.3) Front S-11 S-10 S-4 S-7 S-9 S-3 S-6 S-8 S-2 S-5 S-1 DHLC-4 (Fixed) USB SD Card Holder RS232C Clear S/W Reset S/W MOH EPG

7 “ System Capacities Resources -1 Trunk
- Max.12 = Analog 12 (Max.) + ISDN 6 ports (Max.) - IPGW : 1 x 4ch Extension Ports - D-PT : Max.24 = D-PT + A-PT + DSS + VM (D-PT) + CS (TDA0141) - SLT : Max.24 = SLT + VM (DTMF) Resources MOH Port Pager Port PC Console PC Phone Doorphone Door opener DISA Ports OGM CS PS VM Unit Port (Ch) MSG waiting Log. SMDR TDA30 1 2 24 4 32 8 28 4 (8ch) 128 100 TDA100/200 2 8 64/128 8/16 64/64 16/32 2/2 12 (24ch) 256 200 Resources Tenant TDA30/100/200 8 COS 64 Trunk group Ext. use group 32 PS ring group Call pick up group ICD-Group 64 (32 Ext./G) VM (DTMF) 2 (32 Ext./G) Queuing time table Idle Ext. Hunting-G 64 (16 Ext./G) Ext. Number digits 1-4 Call park area 100 Conference 3x10 or 8x4 Paging group

8 “ System Capacities Resources -2 Resources Verified user code
TDA30/100/200 4 digits x 1000 Verified code PIN 10 digits x 1000 Special carrier code 16 digits x 20 Host access code 10 digits x 10/TRG DDI table 32 digits x 1000 Emergency dial 32 digits x 10 Quick dial 4 digits x 80 System speed dial Pick up dial 32 digits Redial ARS plan 16 Leading digit 16 digits x 1000 Excepted leading 16 digits x 200 ARS Carrier 10 TIE Routing Table 32 Leading digits 3 PBX Code 7 Resources Toll Restriction level TDA30/100/200 7 Denied Code 16 digits x 100 / level Exception Code Charge Rate 8 digits Denomination 3 Call Log (Outgoing) 100/Ext. Call Log (Incoming)

9 “ System Hardware Trunk Cards
BRI-2 KX-TDA3280 - 2 Port ISDN BRI Card - CO/Extension (Programmable) - RJ-45 x 2 - Power failure port is supported. Max.3 LCOT-4 KX-TDA3180 - 4 Port Analogue CO Card - RJ-45 x 4 - Power failure port is supported. - Line polarity reverse detection - CPC is not supported. Caller ID Card KX-TDA3193 - Bell / ETSI / DTMF - Mounted on LCOT-4 Max.3 - 4ch IPGW Card - G729a/G723.1/G711 - T.38 : Not supported - Web programming (English) IPGW-4 KX-TDA3480 Max.1 Note : All cards for TDA30 are NOT hot swappable

10 “ System Hardware Extension Cards
DLC-4 KX-TDA3171 - 4 Port D-PT Card - D-PT / DSS / CS / VM (D-PT) Max.1 DLC-8 KX-TDA3172 - 8 Port D-PT Card - D-PT / DSS / CS / VM (D-PT) Max.2 SLC-4 KX-TDA3173 - 4 Port SLT Card - 4 DTMF receiver - + 40V Line feed Max.1 SLC-8 KX-TDA3174 - 8 Port SLT Card - 8 DTMF receiver - + 40V Line feed Max.2 Note : Optional DHLC card is not provided. Note : All cards for TDA30 are NOT hot swappable

11 “ System Hardware Optional Cards 1/2
MSG-2 KX-TDA3191 - 2 Port Message/DISA Card - OGM Max.15min, 32messages Max.2 DPH-4 KX-TDA3161 - 4 Port Doorphone Card - Doorphone for T30865 - 4 Door Opener - 4 External Relay Output (Ver.1.1) - 4 External Sensor Input (Ver.1.1) Max.1 Echo-8 KX-TDA3166 - 8 Port Echo Cancelling Card Max.1 Note : All cards for TDA30 are NOT hot swappable

12 “ System Hardware Optional Cards 1/2
Ext. Caller ID KX-TDA3168 - Caller ID Signal Generation Card - Max. 8 SLT (4ports x 2resources) - FSK Signal V23/Bell202 - 1st Bell -- Caller ID -- 2nd Bell Max.1 RMT KX-TDA3196 - Analog Modem Card. - V.90 Support. Max.1 Note : All cards for TDA30 are NOT hot swappable Additional AC power adapter (it is the same as packed adapter) KX-A236 When the total number of PT (*) exceeds 4, or the total number of CS exceeds 4, an additional AC power adapter is required. * defined as A-PT, T72xx, T74xx, T75xx (except T7560/T7565) and all DSS Consoles. When a BRI card is configured as “internal ISDN” and feeds DC power. Max.1

13 “ System Hardware AC Adapter Selection AC Adapter Capability
Supplied AC Adapter only: Max. 32 power units + Second Adapter: Max. 96 power units SLT T76xx & T7560/T7565 Other type DPT & APT CS TDA0141 ISDN Terminal Total units Second Adapter Power unit 4 4 1 AC Adapter Selection Sample 1 0-24 24 No 2 0-24 Max 4 Max 4 32 No 3 0-24 Over 4 - Yes 4 0-24 Over 4 - Yes 5 0-24 4 4 1 33 Yes 6 0-24 4 3 4 32 No 7 0-24 4 3 5 33 Yes 8 0-24 3 4 4 32 No 9 0-24 3 4 5 33 Yes

14 “ Maximum Cabling Distance ø0.4mm 500m ø0.5mm 720m (CAT5) ø0.6mm 830m
- T76xx Series - T7550/T7565 ø0.4mm 140m ø0.5mm 229m (CAT5) ø0.6mm 360m - Other D-PT/A-PT - All DSS ø0.4mm 698m ø0.5mm 1128m (CAT5) ø0.6mm 1798m - SLT ø0.4mm 227m ø0.5mm 347m (CAT5) ø0.6mm 500m - TDA0141(CS) USB 5m Point to Point 1000m (CAT5) Point to Multi-Point 150m (CAT5) - ISDN Terminal ISDN S0 Bus 5m USB Terminal USB USB Terminal

15 “ System Comparison TDA30 & TDA100/200 Trunk Extension Other IPGW-4
PRI-30 BRI-8 BRI-4 CID (CO) CID/PAY8 E1 E&M LCOT-16 LCOT-8 LPR Card LCOT-4 BRI-2 TDA3480 - TDA3193 TDA30 TDA3180 TDA3280 TDA0480 TDA0290 TDA0288 TDA0284 TDA0193 TDA0189 TDA0188 TDA0184 TDA0181 TDA0180 TDA100/200 MSLC-16 SLC-16 DHLC-8 DLC-16 DLC-8 SLC-8 LPR Card TDA30 TDA100/200 DLC-4 SLC-4 CS I/F - TDA3172 TDA3174 TDA3171 TDA0175 TDA0174 TDA0170 TDA0172 TDA0171 TDA0173 TDA0144/0143 Other Ext. CID MSG RTM Card TDA3168 TDA3191 TDA3196 TDA30 - TDA0191 TDA0196 TDA100/200 CTI-LINK TDA0410 Echo DPH-2 DPH-4 OPB-3 TDA3166 TDA3162 TDA3161 TDA0166 TDA0162 TDA0161 TDA0190

16 “ Hardware Outline Front View - DLC-8 (Max.2) - SLC-8 (Max.2)
- IPGW-4 (Max.1) - Doorphone (Max.1) - MSG (Max.2) - Ext.Caller ID (Max.1) - Echo chancel (Max.1) - DLC-4 (Max.1) - SLC-4 (Max.1) - BRI-2 (Max.3) - LCOT-4 (Max.3) S-11 S-10 S-4 S-7 S-9 S-3 S-6 S-8 S-2 S-5 S-1 DHLC-4 (Fixed) USB SD Card Holder RS232C Clear S/W Reset S/W MOH EPG

17 Hardware Outline Rear View Power S/W Battery Backup connector
for KX-A228 AC Power Adapter Additional AC Power Adapter KX-A236

18 “ CO Line Configuration CO Trunk Without IPGW card
CO/Ext IPGW BRI Analog Total Slot CO Trunk 01 - 02 03 04 05 06 07 BRI-2 - LCOT-4 4 8 12 08 09 10 CO Trunk With IPGW card 11 4 YES 12 16

19 “ Extension Configuration Built-in Line/Ext. Ext.-1 Ext.-2 SLT D-PT
Slot Without DXDP With DXDP 01 4S/4D - 4 8 02 03 04 05 06 07 4S/4D SLC(S4) - SLC(S8) DLC(D8) 8 4 16 12 24 20 8 16 20 24 4 12 08 09 10 11 12 13 4S/4D DLC(D4) - SLC(S8) DLC(D8) 4 8 12 16 20 24 4 16 12 24 20 8

20 “ Digital Extra Device Port (Digital XDP)-1/3
- DPT on DPT without additional HW or SW - Easy installation for additional Extensions - One DHLC port can be used for three telephones (2 x D-PT + 1 x SLT) - One DLC port can be used for two telephones (2 x D-PT) DXDP-Master 2 Wires 2 Wires DXDP-Slave 4 Wires 2 Wires 4 Wires 2 Wires XDP DXDP-Master DXDP-Slave

21 “ Digital Extra Device Port (Digital XDP)-2/3
Connection & Extension Number Assignment DXDP-Slave DXDP-Master XDP DXDP-Master XDP DXDP-Slave

22 “ Digital Extra Device Port (Digital XDP)-3/3 NG DXDP-Master
Condition-1 ø0.4mm Max. 500m ø0.5mm Max. 720m (CAT5) ø0.6mm Max. 830m DXDP-Slave ø0.4mm Max.40m ø0.5mm Max.50m (CAT5) ø0.6mm Max.60m Master Slave - T7625 - T7630 - T7633 - T7636 - T7665 Telephone Can be used - A-PT - T72xx - T74xx - T75xx DSS CS TVP Can not be used Condition-2 Condition-3 - OHCA function can not be used - T7601 (USB) can not be used (PC Phone / PC Console / PC Programming) Condition-4 NG

23 “ New DECT- CS (KX-TDA0141) - Specific CS I/F card is not needed.
- A port on DHLC or DLC4/8 can used as the interface of KX-TDA0141. - Two Voice Path per a CS. - Functionality : The same as TDA0142 ø0.4mm 222m ø0.5mm 347m (CAT5) ø0.6mm 500m Max.4 CS : One AC adapter Max.8 CS : Two AC adapters - CS Port assignment is not needed The TDA30 automatically detects the connected CS.

24 “ Caller ID for SLT (KX-TDA0168)
With the addition of the KX-TDA3168 the TDA30 provides CLIP information for single line telephones. Caller ID data KX-TDA0168 Resource assignment The KX-TDA3168 has 2 resources (4ports/resource=Total 8SLT), the resources assignment for SLT extension card is needed. TDA0168 DHLC SLC-4 SLC SLC SLC SLC 2 resources

25 “ New IPGW Card (KX-TDA3480) - 4ch IPGW Card - G729a/G723.1/G711
- T.38 (FAX) mode is not supported (FAX = G711) - Web programming (English) - Interoperability with TDA0480: Incoming call, Outgoing call and CLIP only. - Interoperability with another manufacturers : Not guaranteed.

26 PC Programming Software
PBX Features (Software) The TDA30 features are the same as TDA100/200 features. Except for; PAYTONE Detection (not available on TDA30) MWL (not available on TDA30) PRI / E1 / E&M (not available on TDA30) CTI Link Card (not available on TDA30) PC Programming Software - Almost the same as TDA100/200 PC programming software.