1
HPWH UES Measure Initial Review 16 April 2014
2
Agenda Provisional Measure Review Method Overview Prelim Findings Measure Development Approach Simulation Validation Please provide feedback and concerns throughout. This is a brainstorming session as much as a presentation.
3
Current Provisional Measures HPWH Type: – Tier 1, 50-75 gallons – Tier 1, 75+ gallons – Tier 2 Unheated buffer locations – Includes garages and basements together Heated installations – One measure for each of gas furnace, electric furnace, zonal resistance, and heat pump heating Tier 1 water heaters have no exhaust ducting Tier 2 water heaters all have exhaust ducting The measures cross the entire PNW and are not separated by climate zone Annual Energy Saving (kWh/yr)Tier 1Tier 2 HPWH LocationSpace Heat Type Small Tank Large TankAny Size Unheated Buffer LocationAny Heat Type 887 1,817 1,794 Interior Location Gas Heated Home 1,547 2,169 1,724 Interior Location Zonal Electric Heated Home 648 957 952 Interior Location Electric Furnace Heated Home 556 833 837 Interior Location Heat Pump Heated Home 1,189 1,686 1,243
4
Method
5
Proven Unit Energy Savings Calibrated Engineering Approach – Heat Pump Water Heater Model Validation and Process Evaluation Project designed specifically to move HPWH measure from provisional to proven status. Even designed under the current guidelines (hooray!) – Final energy savings will be calculated with a simulation of HPWH behavior Inputs to simulation need to be solid Simulation needs to be validated
6
Simulation Inputs & Characteristics Simulation inputs come from the completed field studies: – Inlet water temperature, ambient air temperature, tank set point, water draw pattern – Investigated, categorized, and normalized where necessary (e.g. by climate or number of occupants) To extend to entire PNW, additional characteristics will come from RBSA survey – Ex: occupant count
7
Simulation Validation Validated against field measurements of energy use – Categorized by climate, equipment type, installation location, draw patterns, etc.
8
Preliminary Findings (subject to change. your mileage may vary. etc.) Findings used in two, broad ways: – For simulation inputs – To validate outputs
9
Findings are as expected: Energy use GeoSpring>Voltex>ATI Resistance heat slope is about 0.2 kWh/gal
10
Findings are as expected: Energy use Garage>Basement>Interior
11
More Findings Inlet water – by region / climate Ambient air temperature – by install location Outlet water – input from site visit records on setpoints – measured outlet temperatures
12
Will use inlet measurements to build inlet water temperature profiles for use in simulation as a function of geography
14
Creating Hot Water Draw Profiles Average daily use per person: 17.1 gallons – Provisional measure used 18.2 gallons Will also investigate the following to inform our draw patterns: – Average number of draws per person per day at 1 gallon resolution – Draw sizes Ex: # of 1 gal draws, # of 2 gal draws, # of 3 gal draws, etc….
15
Final UES Development Approach Categories and Prototypes – Are calculated and modeled separately but then combined with weighted averages to produce ultimate savings estimates Climate Zone Installation Location Heating System Type Prototypical Draw Patterns – 1, 2, & 4 person draws
16
Key Assumptions RBSA population characteristics represent the houses installing HPWHs Water draws are the same between ERWH and HPWH – Both are storage tanks – Metered energy data from DHP study and RBSA Metering study can help confirm Space heating interaction – Fractional or full? Current assumption for interior installations is full interaction: one unit of heat removed from the air in the heating season is replaced by one unit of heat output from the heating system – Supplemental heat A negative heating interaction will show up as a change in supplemental heat requirements. Those heat requirements, per the DHP analysis, will show up as a cost in the non-energy benefits stream and not as a penalty to the electric grid.
17
Schedule All analysis currently underway Report writing in April & May Workbook development in May & June Workbook refinement in June & July Final report before RTF presentation Full RTF presentation in July or August
18
Simulation Validation Graphs of metered and simulated data Work still underway to tune the simulation
19
Voltex 60: Measured & Modeled
20
Voltex 80: Measured & Modeled