1 Power Losses due to Button and Reentrant BPMs Igor Zagorodnov and Dirk Lipka 01.10.07 BD meeting, DESY

2 Button BPM

3 gap=1mm Gaussian bunch with sigma=2mm Loss = 0.05 kV/nC Kick = 0.2 kV/nC/m Accuracy Test of CST Microwave Studio -> OK

4 Gaussian bunch with sigma=1mm Loss = 0.047 kV/nC Kick = 0.13 kV/nC/m BPM with Microwave Studio Gaussian bunch with sigma=25mkm Loss = 0.3 kV/nC Kick = 0.02 kV/nC/m

5 Rotationally symmetric model with ECHO (as an estimation from above) g=1mm sigma, m Loss, kV/nC Kick, kV/nC/m 20000.110.44 1000.770.143 251.680.076 Analytical estimation (K.Bane, Sands M., SLAC-PUB-4441, 1987) a=39mm

6 Power Loss (upper level, round approx.) (real, scaled, see slide 4)

7 gap=8.5 mm Reentrant BPM

8 Gaussian bunch with sigma=25 mkm Loss (analytical) = 2.77 kV/nC Loss (ECHO) = 2.68 kV/nC Reentrant BPM g=8.5 mm, a=39 mm z [cm] r [cm]

9 Long range wake Up to 3 m for sigma =2.5 mm Reentrant BPM Prony-Pisarenko fit P. Thoma, Berechnung der Güten einiger Resonanzen eines verlustfreien Resonators mit angekoppeltem verlustfreien Wellenleiter. (1992, Darmstadt, Diplomarbeit betreut bei Martin Dohlus)

10 Long range wake Freq, GHz2*K_n, kV/nCalphaQ 11.220.1050Inf 23.810.0990.225.3634 35.910.0710.0824.3639 48.10.0520.1714.8516 513.20.0120.142.3142 Loss for sigma = 25mkm (ECHO) = 2.68 kV/nC f [Hz] k [kV/C] W [kV/nC] s [cm] wake Modal loss factor

11 Button BPM vs. Reentrant BPM for sigma = 25mkm Loss factor, kV/nC Power loss, Watt Button BPM0.30.03 Button BPM (optimized for signal) 0.80.08 Reentrant BPM2.70.26

12 BPM vs. others for sigma = 25mkm Loss factor, kV/nC Power loss, Watt Button BPM (optimized for signal) 0.80.08 Reentrant BPM2.70.26 10 flange gaps (0.6 mm)0.66*10=6.60.64 TESLA Cryomodule (including belows) 14814.4 superconductive normal conductivity

13 Acknowledgements - to Martin Dohlus for useful discussions - to Rolf Schuhmann for Prony-Pisarenko Matlab script - to CST GmbH for the new wakefield solver